Text
__
's l
Westinghouse Energy Systems Ba 355 l
Electric Corporation Pittsburgh Pennsylvania 15230-0355 DCP/NRC1399 NSD-NRC-98-5740 Docket No.: 52-003 July 21,1998 1
1 Document Control Desk U. S. Nuclear Regulatory Comtr.ission Washington, DC 20555 l
. ATTENTION: T. R. QUAY l
SUBJECT:
FINAL RESPONSES TO ALL NRC REQUESTS FOR INFORMATION j
i
Dear Mr. Quay:
This letter is provided in response to an E-mail from Thomas Kenyon to Brian McIntyre dated July 17, 1998, on RAls without apparent responses. The responses or references to previous responses is l
provided below.
l RAI#
NRC
Response
l letter date I
i 280.38F 4/8/98 This RAI requested consideration of the location of the fire pumps. A l
response was provided in Westinghouse letter DCP/NRCl347 dated April l
23,1998.
410.234 5/23/94 This RAI requested additional detailed design information on several 7
l HVAC systems. This request was the subject of several meetings and
/
l phone calls between Westinghouse and the NRC Staff. During these meetings and calls, agreement was reached on the extent of design
)
information for these systems to be included in the SSAR. As of Revision 23 of the SSAR, this information is included in the SSAR text, tables, or figures.
410.299 10/17/96 This RAI requested that information deleted from the SSAR in previous j
revisions be returned to the SSAR. This request was the subject of j
several meetings and phone calls between Westinghouse and the NRC Staff. During these meetings and calls, agreement was reached on the extent of design information for these systems to be included in the SSAR. As of Revision 23 of the SSAR, this information is included in the SSAR text, tables, or figures.
~
9907290302 990721 PDR ADOCK 05200003,
A PDR
4 DCP/NRCl399 f
NSD-NRC-98-5740 July 21,1998 RAI #
NRC
Response
l letter date l
440.746F 12/08/97 This RAI stated that the staff review of OSU/ APEX testing was not j
complete. Westinghouse understands that the staff review of this testing is now complete and no action is required from Westinghouse.
i l
620.94 5/15/95 The response for this RAI was provided in Westinghouse letter l
DCP/NRC0578, dated August 13, 1996. A copy of the response is attached for your use.
210.195 12/7/96 This RAI referenced an RNS valve in error. Response Revision I for RAI 210.24 included response to the questions in the 12/7/98 letter.
Subsequent meetings and telephone calls among NRC staff, NRC consultants, and Westinghouse resolved questions about inservice l
questions and are reflected in SSAR subsection 3.9.6.
l 210.225 8/20/96 This RAI requested that Westinghouse discuss certain issues during a i
subsequent meeting. These issues were discussed during a telephone call on August 8.1996.
210.232F 11/17/97 This RAI noted that information committed to be included in WCAP-l 13054 was not yet included. A subsequent revision of the WCAP includes the information.
1 l
210.233F 11/17/97 This RAI noted that information committed to be included in WCAP-
)
13054 was not yet included. A subsequent revision of the WCAP includes the infc -mation.
440.779F 12/16/97 This RAI noted that a technical specification change committed to previously should be included in the next revision of the technical specifications. This change was included in Revision 8 of the technical speci0 cations.
440.780F 12/16/97 This RAI noted that a technical specification change committed to t
previously should be included in the next revision of the technical specifications. This change was included in Revision 8 of the technical l.
specifications.
est for additional information responses from Westinghouse.
This response completes a re d.:~. McIntyre, Manager
/st" Brian A Advanced Plant Safety and Licensing jml Attachment ec: T. J. Kenyon, NRC i
H. A. Sepp, Westinghouse l
nm,r
's NRC REQUEST FOR ADDITIONAL INFORMATION 4
E=:
1 Question 620.94 A description of how the integrated role of the operator across all systems is confirmed for acceptability (as discussed in Part 2 - Section 2 of this document). If function allocation was performed by individual system designers, with the IAEA process described in the RAI responses by used at all, and if so how? Will the URD processes be used?
The pmcess should be described by which functions are re-allocated in an iterative manner, in response to developing
- design specUics, operating experience, and the outcomes of on-going analyses and trade studies.
Response
The methodology ' sed for function allocation in the AP600 design process has been provided in a draft u
WCAP-14644, AP600 Functional Requirements Analysis and Function Allocation, submitted by NSD-NRC-96-4722 on 5/14/96.
O e
i e
e 4
P 420.125-1 l
_