NSD-NRC-96-4875, Forwards Rev 2 of AP600 Certified Design Matl,Including Insps,Tests,Analyses & Acceptance Criteria

From kanterella
(Redirected from NSD-NRC-96-4875)
Jump to navigation Jump to search
Forwards Rev 2 of AP600 Certified Design Matl,Including Insps,Tests,Analyses & Acceptance Criteria
ML20149L710
Person / Time
Site: 05200003
Issue date: 11/07/1996
From: Mcintyre B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Quay T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20149L713 List:
References
NSD-NRC-96-4875, NUDOCS 9611140182
Download: ML20149L710 (1)


Text

_-__--------

/~%

[ :c h j

. =.

(O =

i Westinghouse Energy Systems Electric Corporation g0pnnenmaa-0355 NSD-NRC-96-4875 DCP/NRC0651 Docket No.. STN-52-003

+

November 7,1996 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ATTENTION: T.R. QUAY

SUBJECT:

REVISION 2 OF TIIE AP600 CERTIFIED DESIGN MATERIAL Dear Mr. Quav-Enclosed is Reywon 2 of the AP600 Certified Design Material (CDM), including the Inspections, Tests, Analyses and Acceptance Criteria (ITAAC). This revision supersedes Revision I which was submitted in December 1992. The Revision is in the form of a complete replacement. Thirty-six copies of this update are being sent to Mrs. Diane Jackson for distribution to the NRC +.aff.

Per our discussions with Mr. Sebrosky of your staff, this letter also confirms our meeting on Wednesday, November 13,1996 from 9:00AM to 12:00N in the Westinghouse Rockville Nuclear Licensing Center. The purpose of the meeting is to describe the process we used to select tier 1 material, and to compare our submittal with the drafi Standard Review Plan Section 14.3 which was issued in April 1996.

This information includes no information classified as proprietary.

Please contact Brian A. McIntyre on (412) 374-4334 if you have any questions concerning this transmittal.

A /

Brian A. McIntyre, Manager Advan 1 Plant Safety and Licensing I

/nj.a b /

Attachments Enclosures

- cc: J. Sebrosky, NRC/NRR -

N. Liparulo, Westinghouse (w/o attachments and enclosures) j 2m4

^

9611140182 961107 PDR ADOCK 05200003 A PDR