Text
-.
f i
Westinghouse Energy Systems Ba 355 Electric Corporation Pittsburgh Pennsylvania 15230-0355 t
NSD-NRC-964845 DCP/NRC0626 Docket No.: STN-52-003 October 17,1996 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 l
1
]
ATTENTION:
T.R. QUAY
SUBJECT:
COMPLETION OF WESTINGIIOUSE ACTIVITIES RELATED TO NUREG 0711
References:
1.
NRC letter to Westinghouse, " Summary of Meeting to Discuss lluman Factors
)
Engineering for the Design of the AP600," March 24,1995.
2.
NRC letter to Westinghouse, "IIFE Insights for Advanced Reactors Based on 1
Operating Experience," February 13, 1995.
i 3.
NRC letter to Westinghouse, "liuman Factors Comments on the AP600 Draft Operating Experience Review Report," August 12, 1996.
4.
NSD-NRC-96-4831 (DCP/NRCM14), dated October 9,1996, WCAP-14644 l
and WCAP-14651.
i
Dear Mr. Quay:
l Please find enclosed WCAP-14645, Revision 1, "Iluman Factors Engineering Operating Experience j
Review Report for the AP600 Nuclear Power Plant." Submittal of this WCAP closes DSER OITS
{
items 1316 through 1322 and 2063 and completes Westinghouse activities related to NUREG-0711
{
Element 2. In addition, a table is attached to this transmittal letter which lists the DSER Chapter 18 l
open items which are repeated as DSER Chapter 20 open items, all of which are also closed by this i
transmittal.
1 j
DSER open item 1319 is also closed since a copy of the eight references for Table 3 of the attached
-WCAP are now available for audit in the Westinghouse Rockville 1.icensing Office.
By Reference 1, Westinghouse was requested to review NUREG-0711 Appendix B and Reference 2 i
the NRC with a list of differences. A fax was transmitted to the NRC on 4/24/95 which listed those
'l against NUREG-0933 and SSAR Table 1.9.4 for low, non-prioritized, or dropped issues and provide issues Westinghouse thought should not be addressed in the liuman Factors Engineering Operating
/
Experience Review (OER) Report for the AP600. The NRC reviewed this list and a telecon involving, '
f, Lhh 9610280169 961017 PDR ADOCK 05200003 A
NSD-NRC-%-4845 DCP/NRC0626 October 17, 1996 Messrs. Span and Kerch of Westinghouse and Messrs. liuffman and.Bongarra of the NRC was held on June 19, 1995. During this telecon, agreement was reached as to which items were to be included in OER Table I with simply a reference to the telecon that these issues were dropped. As evidenced in Reference 3, no review comments were provided which are contrary to this agreement.
As discussed in Reference 4, this transmittal completes Westinghouse activities related to NUREG-0711. It also closes all DSER Chapter 18 open items which are not associated and assigned to the ITAACs and enables the NRC to complete Chapter 18 of the AP600 FSER.
Please contact Robin K. Nydes on (412) 374-4125 if you have any questions regarding any of the SSAR Chapter 18 WCAP submittals.
A Brian A. McIntyre, anager Advanced Plant Safety and Licensing
/nja Enclosures Attachment cc:
W. Iluffman, NRC (9E)
J. Bongarra, NRC (IE) q II. Li, NRC (IE)
J. liiggins, BNL (1E)
N. Liparulo, Westinghouse (w/o attachments / enclosures) 2956A
. _. ~....
NSD-NRC-96-4845 DCP/NRC0626 October 17,1996 l
bec:
M. D. Beaumont Rockville, MD IL j
J. C. Butler WEC 3-09 East IL P. A. Chahoy WEC 4-15 East IL B. Z. Cowan Eckert, Seamans, Cherin & Mellott IL S. M. Franks DOE IL S. P. Kerch WEC 4-30 East IL,4E J. M. Moore Expo Mart 335 IL R. K. Nydes WEC 3-08 East IL,IE-R. B. Schreiber WEC 3-07 East IL C. Thompson DOE IL J. W, Winters WEC 3-08 East IL l
R. M. Vijuk WEC 3-7A East IL AP600 Central File WEC 3-15 East IL, IE File 9.0 WEC 3-09 East IL 1
1 t
2956A
f DSER CIIAPTER 18 OER ITDIS RELATED TO DSER CIIAITER 20 OITS ITDI #
DSER SECTION DSER PAGE #
BRIEF ISSUE DESCRIITION ISSUED ADDRESSED BY Part of 1317 Part of 18.3.3.1-2 USI/GSI Issue B-17: Criteria for SSAR Section 1.9.4.2.2 N/A 20 20-44 Safety-Related Operator Actions OER Table 1, item 3 1317 Part of 18.3.3.1-2 TMI Issue I.A.I.4: Long-Term OER Table 1, Item 48 Upgrading of Operating Personnel 1524 20.4-1 20-108 and Staffing 1317 Part of 18.3.3.1-2 TMI Issue I.A.4.2: Long Term OER Table 1, Item 49 1980 20.4-3 20-110 Training Simulator Upgrade N/A References SSAR TMI Issue I.C.1: Guidance for OER Table 1, Item 50 Section 18.9.8 Evaluation and Development of Procedures for Transients and 1525 20.4-2 20-111 Accidents 1317 Part of 18.3.3.1-2 TMI Issue I.C.5: Procedures for SSAR Sections 13.2 Feedback of Operating Experience and 13.5 1526 20.4-3 20-113 to Plant Staff 1317 Part of 18.3.3.1-2 TMI Issue I.C.9: Long-Term OER Table 1, Item 51 1527 20.4-4 20-113 Program for Upgrading Procedures 1317 Part of 18.3.3.1-2 TMI Issue I.D.1: Control Room SSAR Section 1.9.3 (2)(iii)
N/A 20 20-114 Design Reviews OER Table 1, Item 52 1317 Part of 18.3.3.1-2 TMI Issue I.D.2: Plant Safety SSAR Section 1.9.3.(2) (iv) t N/A 20 20-115 Parameter Display Console OER Table 1. Item 34 and 53 1317 Part of 18.3.3.1-2 TMI Issue II.K.l(5): Safety-Related OER Table 1, Item 57 1489 20.1-3 20-162 Valve Position Description 1
2956A
DSER CIIAI'TER 18 OER ITEMS RELATED TO DSER CIIAPTER 20 OITS ITEM #
DSER SECTION DSER PAGE #
BRIEF ISSUE DESCRIPTION ISSUED ADDRESSED BY 1317 Part of 18.3.3.1-2 TMI Issue II.K.l(10): Review and SSAR Section 1.9.4.2.1 Modify Procedures for Removing OER Table 1. Item 58 1489 Safety-Related Systems From 20.1-3 20-163 Service 1317 Part of 18.3.3.1-2 OER Table 1, Item 21 N/A 20 20-187 Issue HFl.1 Shift Staffing N/A References SSAR Issue IIF4.1 Inspection Procedure SSAR Section 13.5 Section 18.9.8 for Upgraded Emergency Operating 1557 20.5-1 20-188 Procedures 1317 Part of 18.3.3.1-2 IIF4.4: Guidelines for Upgrading SSAR Section 1.9.4.2.4 1489 20.1-3 20-188 Other Procedures OER Table 1, item 22 1317 Part of 18.3.3.1-2 IIF5.1: Man-Machine Interface -
SSAR Section 1.9.4.2.4 N/A 20 20-189 Local Control Stations OER Table 1, Item 24 1317 Part of 18.3.3.1-2 IIF5.2: Review Criteria for lluman SSAR Section 1.9.4.2.4 Factors Aspects of Advance OER Table 1, Item 25 1558 20.5-2 20-190 Controls and Instrumentation 29%A
,_