NSD-NRC-96-4670, Forwards QA Program Requirements for Rtnss Sys,Structures & Components, Per GL 85-06

From kanterella
(Redirected from NSD-NRC-96-4670)
Jump to navigation Jump to search
Forwards QA Program Requirements for Rtnss Sys,Structures & Components, Per GL 85-06
ML20101H577
Person / Time
Site: 05200003
Issue date: 03/26/1996
From: Mcintyre B
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: Quay T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20101H581 List:
References
GL-85-06, GL-85-6, NSD-NRC-96-4670, NUDOCS 9603290361
Download: ML20101H577 (4)


Text

_

~

~

Westinghouse Energy Systems Box 355 Electric Corporation Pittsbun a DannsyNania 15230 0355 NSD-NRC-964670 DCP/NRC0481 Docket No.: STN-52-003

~

March 26,1996 Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ATTENTION:

T.R. QUAY

SUBJECT:

QUALITY ASSURANCE REQUIREMENTS FOR AP600 RTNSS SYSTEMS, STRUCTURES, AND COMPONENTS

Dear Mr. Quay:

In the Draft Safety Evaluation Report (DSER) for the AP600, the staff requested that the QA applied to RTNSS should be comparable to that described in Generic Letter 85-06 for ATWS, as well as Regulatory Position 3.5 and Appendix A of RG 1.155 for non-safety-related station blackout equipment (DSER open item 17.1.3-1). Westinghouse is preparing a QA program requirements document, based on these standards, for use in RTNSS SSC procurements. The requirements that are to be included in this document are included for information as Attachment I to this letter.

Please contact John C. Butler on (412) 374-5268 if you have any questions concerning this transmittal.

Y ff Brian A. McIntyre, Manager Advanced Plant Safety and Licensing i

/nja Enclosure cc:

T. Kenyon, NRC N. J. Liparulo, Westinghouse (w/o Enclosure) 29CC81 gI

}

9603290361 960326 PDR ADOCK 05200003 A

PDR L