NRC 2012-0068, Licensee Qualification for Performing Dynamic Rod Worth Measurement Analysis
| ML122541058 | |
| Person / Time | |
|---|---|
| Site: | Point Beach |
| Issue date: | 09/10/2012 |
| From: | Jim Costedio Point Beach |
| To: | Office of Nuclear Reactor Regulation, Document Control Desk |
| References | |
| NRC 2012-0068 | |
| Download: ML122541058 (7) | |
Text
September 10,2012 NEXTer=
POINT BEACH NRC 2012-0068 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Units 1 and 2 Dockets 50-266 and 50-301 Renewed License Nos. DPR-24 and DPR-27 Licensee Qualification for Performing Dvnamic Rod Worth Measurement Analvsis NextEra Energy Point Beach, LLC (NextEra) intends to use Westinghouse supplied methods to perform physics calculations in support of Dynamic Rod Worth Measurement (DRWM) for low power physics testing for Point Beach Nuclear Plant (PBNP), Units 1 and 2. This testing is expected to take place in November 2012. The Safety Evaluation Report issued by the NRC for WCAP-13360-P-A, Revision 1, 'Westinghouse Dynamic Rod Worth Measurement Technique,"
contains the requirements to provide the NRC confirmation that the competencies to perform DRWM design calculations will be demonstrated. Enclosures 1 and 2 demonstrate that these criteria have been met for PBNP. Documentation of training, qualification, and benchmark calculations is available from NextEra Energy, Juno Beach Headquarters - Nuclear Fuels department, for review.
This letter contains no new Regulatory Commitments and no revisions to existing Regulatory Commitments.
If you have any questions or require additional information, please contact Jay Kabadi, Manager of PBNP Nuclear Fuel Engineering, at 5611694-3364.
Very truly yours, NextEra Energy Point Beach, LLC James Costedio fl Licensing Manager Enclosures cc:
Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC NextEra Energy Point Beach, LLC, 6610 Nuclear Road, Two Rivers, WI 54241
ENCLOSURE I NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 DEMONSTRATION OF THE ABILITY TO PERFORM COMPUTATIONS TO SUPPORT DYNAMIC ROD WORTH MEASUREMENTS INTRODUCTION Westinghouse performed the initial application of Dynamic Rod Worth Measurements (DRWM) at Point Beach Nuclear Plant (PBNP) in 1999. NextEra Energy Point Beach, LLC (NextEra) intends to perform the analytical computations necessary to support the DRWM. contains approved NRC criteria needed to be met in order to perform computations to support DRWM. Successfully meeting these criteria constitutes inherent NRC approval to use DRWM in Low Power Physics Testing (LPPT). This report demonstrates that these criteria have been met.
Station personnel received training and procedures on the use of the Advanced Digital Reactivity Computer (ADRC), and application of the ADRC to performing LPPT using DRWM prior to the test.
Added training was also received during the initial application of DRWM. Personnel performing computations to support DRWM were trained by Westinghouse in these computations from August 16 to August 20,201 0, and received procedures on how to perform these computations at that time. This training included the ability to set up input, understand and interpret output results, understand applications and limitations, and to perform analyses in compliance with the procedures provided by Westinghouse.
Cross sections to support DRWM computations are obtained from the Phoenix-P lattice physics code (Reference 1). The flux solutions for these computations are obtained from the Advanced Nodal Computer (ANC) Code (Reference 2). NRC review and approval of these codes and the procedures by which NextEra uses these codes is contained in Reference (3). Application of these codes and procedures, and the Westinghouse DRWM procedure, is controlled by the NextEra Quality Assurance Program defined in Reference (4). This Quality Assurance Program meets the requirements of 10 CFR 50, Appendix B.
RESULTS Table 1 provides the DRWM measured and predicted rod worths based on Westinghouse predictions for the PBNP Unit 1, Cycle 33 LPPT. Table 2 provides the DRWM measured and predicted rod worths based on NextEra predictions for the PBNP Unit 1, Cycle 33 LPPT.
Table 3 compares the Westinghouse (Table 1) and NextEra (Table 2) predicted rod worth data for PBNP Unit 1, Cycle 33 LPPT. Table 4 compares the rod worths measured by the DRWM technique using Westinghouse analytical data to support the rod worths measured by NextEra analytical data.
Page 1 of 3
Table 2: Measured and Predicted Rod Worths Based on Table I: Measured and Predicted Rod Worths Based on Westinghouse Predictions for PBNP Unit 1, Cycle 33 LPPT NextEi-a Predictions for PBNP Unit 1, Cycle 33 LPPT 11 Bank SB SA CD CC CB CA TOTAL Bank Worth (pcm)
Difference Measured Predicted pcm (M-P)
I
% ((M-P)IP)
TOTAL 51 73.6 51 05.4 68.2 1.34 Worth (pcm)
Page 2 of 3 Measured 748.4 796.9 825.1 900.4 676.6 1214.1 51 61.5 Difference Table 3: Comparison of Predicted Rod Worths Based on Westinghouse and NextEra Data for PBNP Unit I, Cycle 33 LPPT Predicted 758.4 767.7 803.8 898.4 692.8 11 82.9 51 04.0 pcm (M-P)
-1 0.0 29.2 21.3 2.0
-1 6.2 31.2 57.5 Bank SB SA CD CC CB CA TOTAL
% ((M-P)IP)
-1.32 3.80 2.65 0.22
-2.34 2.64 1.13 Predicted Rod Worth (pcm)
Westinghouse 758.4 767.7 803.8 898.4 692.8 11 82.9 5104.0 Difference NextEra 757.9 767.9 803.7 899.3 691.9 11 84.7 5105.4 pcm (N-W)
-0.5 0.2
-0.1 0.9
-0.9 1.8 1.4
% ((N-W)NV)
-0.07 0.03
-0.01 0.1 0
-0.13 0.15 0.03
Table 4: Comparison of Measured Rod Worths Based on Westinghouse and NextEra Supporting Analytical Data for PBNP Unit 1, Cycle 33 LPPT DISCUSSION OF RESULTS CA TOTAL Table 3, comparing Westinghouse and NextEra predicted results, shows the maximum pcrn difference in the predicted worth of any bank to be 1.8 pcrn (Bank CA), and the maximum percent difference in the predicted worth of any bank is 0.1 5% (Bank CA). The difference in the total predicted rod worth is 1.4 pcm, or 0.03%.
Bank SB Comparing measured results based on Westinghouse and NextEra supporting analytical data, Table 4 shows the maximum pcrn difference in the measured worth of any bank is 3.3 pcrn (Bank CC), and the maximum percent difference in the measured worth of any bank is 0.37% (Bank CC). The difference in the total measured rod worth is 12.1 pcm, or 0.23%.
Difference 1214.1 51
61.5 CONCLUSION
S Pcm (N-W) 1.2 Measured Rod Worth (pcm)
Based on the results, NextEra concluded that the review criteria in the document in Enclosure 2 have been met; therefore, NextEra has demonstrated the qualification to perform their own analytical computations to support DRWM tests for future LPPT. The first application of NextEra analytical computations to support DRWM in LPPT will occur with the start up of PBNP Unit 2, Cycle 33, which is expected to take place in November 2012. As PBNP Unit 1 and 2 are similar in design, these conclusions are valid for both units.
% ((N-W)N) 0.16 Westinghouse 748.4 1216.0 51
73.6 REFERENCES
NextEra 749.6 Nguyen, T. Q., et al., "Qualification of the Phoenix-PIANC Nuclear Design System for Pressured Water Reactor Cores," WCAP-11596-P-A, June 1988 (Westinghouse Proprietary) 1.9 12.1 Liu, Y. S., et al., "ANC: A Westinghouse Advanced Nodal Computer Code,"
WCAP-10965-P-A, September 1986 (Westinghouse Proprietary) 0.16 0.23 Bordelon, F. M., et al., "Westinghouse Reload Safety Evaluation Methodology,"
WCAP-9272-P-A, July 1985. (Westinghouse Proprietary)
FPL-1, Revision 12, "Quality Assurance Topical Report," July 3, 2012 Page 3 of 3
ENCLOSURE 2 NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS I AND 2 CRITERIA FOR A UTILITY PERFORMING DYNAMIC ROD WORTH MEASUREMENT COMPUTATIONS In order for a utility to perform their own physics calculations to support the use of the Dynamic Rod Worth Measurement (DRWM) technique during the Low Power Physics Testing (LPPT), the following five criteria must be met. Compliance with the following five criteria demonstrates a utility's qualification and constitutes inherent NRC approval to use DRWM in their LPPT. To document its qualification, the utility must send the NRC a notification of compliance with the criteria and the date of the intended first application of the codes to determine the DRWM physics constants for LPPT. Any voluntary limitations or restrictions of the utility's use of the DRWM methodology must also be addressed in the notification. The NRC would then, at their option, audit the application of the utility's DRWM program to ensure compliance.
The five Westinghouse Criteria are shown below, along with a description of how NextEra Energy Point Beach, LLC (NextEra) complies with each of the criterion.
Criterion 1 : Eligibility of Codes for DRWM Computations Only lattice physics codes and methods which have received prior NRC review and approval are eligible to be used in determining the physics constants to be used in DRWM. The NRC review ensures that the codes being used for the DRWM computations were developed under a qualified QA program and were properly benchmarked and verified.
NextEra Compliance: Phoenix-P (Reference 1) and Advanced Nodal Code (ANC) (Reference 2) packages, previously approved by the NRC, will be used by NextEra in determining the DRWM constants.
Criterion 2: Application of Procedures to DRWM Computations In a manner consistent with the procedures obtained from Westinghouse, the utilify analyses shall be performed in conformance with in-house application procedures which ensure that the use of the methods is consistent with the Westinghouse approved application of the DR WM methodology.
NextEra Compliance: NextEra in-house procedures are based on, and are consistent with, the Westinghouse approved application of the DRWM methodology.
Page 1 of 3
Criterion 3: Training and Qualification of Utility Personnel The first application of DRWM for LPPT will be performed by Westinghouse. This will ensure that DR WM is applicable to the specific plant, provide utility personnel with training in the DRWM technique and be used to meet Criterion 4 - Comparison Calculations for the DRWM Technique.
The first application of DRWM for LPPT by Westinghouse will be applicable for all of the same plant type at the plant site of application. If the fuel vendor should change subsequent to the first application, a second application by Westinghouse is not required, Utilities shall establish and implement a training program to ensure that each qualified user of the DRWM methodology has a good working knowledge of the codes and methods used for DRWM.
This training shall include the ability to set up input decks, understand and interpret output results, understand applications and limitations, and to perform analyses in compliance with the procedures provided by Westinghouse.
NextEra Compliance: Westinghouse performed the first application of DRWM for Point Beach Nuclear Plant in 1999. NextEra personnel, performing the DRWM constants, received training from Westinghouse on the application of DRWM methodology using NRC approved codes (References 1 and 2). The training covered all the key aspects of DRWM process including inputs and interpretation of results. Enclosure 1 provides the benchmark data generated by NextEra personnel demonstrating ability to perform calculations in support of DRWM, using Westinghouse procedures. NextEra personnel will perform cycle specific DRWM calculations consistent with the Westinghouse procedures and will be required to maintain their qualifications under the NextEra training program.
Criterion 4: Comparison Calculations for the DRWM Technique Prior to the first application by a utility using their own methods to perform physics calculations in support of DRWM for LPPT, the utility will demonstrate its ability to use the methods supplied by Westinghouse by comparing its calculated results with the analyses and results obtained by Westinghouse during the first, or subsequent, application(s) of DRWM at the utility's plant, These comparisons must be documented in a report which is part of the utility's QA records. Any significant differences between the calculations and the comparison data must be discussed in the report. As a minimum, the following parameters should be compared to the supplier of the DRWM methodology calculations, and should agree within the given acceptable deviation:
Parameter Calculated Bank Worth Calculated Total Worth of All Banks Measured Bank Worth Obtained for First Application Measured Total Worth Obtained for First Application Acce~table Deviation
+2% or +25 pcm
+2% or +25 pcm NextEra Compliance: The comparison calculations for the application of DRWM methodology showed results with deviations well within the above acceptance criteria. The calculations are prepared and maintained as QA records under the NextEra Quality Assurance Program.
Page 2 of 3
Criterion 5: Quality Assurance and Change Control All calculations for DRWM by a utility using the Westinghouse methodology which has been approved by the NRC shall be conducted under the control of a quality assurance program which meets the requirements of 10 CFR 50, Appendix. The utility QA program will also include the following:
a) A provision for implementing changes in the methods and procedures being used for DRWM.
b) A provision for informing Westinghouse of any problems or errors discovered while using the DRWM methods or procedures. '
NextEra Compliance: The calculations for DRWM will be performed under the NextEra Quality Assurance Program, meeting the 10 CFR 50, Appendix B requirements. This Quality Assurance Program includes provisions for implementing changes as necessary, and reporting to Westinghouse any errors identified during the use of the DRWM methodology.
References (1)
Nguyen, T. Q., et al., "Qualification of the Phoenix-PIANC Nuclear Design System for Pressured Water Reactor Cores," WCAP-11596-P-A, June 1988 (Westinghouse Proprietary)
(2)
Liu, Y. S., et al., "ANC: A Westinghouse Advanced Nodal Computer Code,"
WCAP-10965-P-A, September 1986 (Westinghouse Proprietary)
Westinghouse has a requirement to inform utilities that have taken a Technology Transfer on DRWM of changes to the process as part of their QA procedures regarding Technology Transfer.
Page 3 of 3