NRC 2010-0080, License Amendment Request 261, Extended Power Uprate, Response to Request for Additional Information
| ML101610710 | |
| Person / Time | |
|---|---|
| Site: | Point Beach (DPR-024, DPR-027) |
| Issue date: | 06/10/2010 |
| From: | Meyer L Point Beach |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| NRC 2010-0080 | |
| Download: ML101610710 (3) | |
Text
June 10,201 0 NE>CTera TM POINT BEACH NRC 201 0-0080 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Units 1 and 2 Dockets 50-266 and 50-301 Renewed License Nos. DPR-24 and DPR-27 License Amendment Request 261 Extended Power Uprate Response to Request for Additional Information
References:
(I)
FPL Energy Point Beach, LLC letter to NRC, dated April 7, 2009, License Amendment Request 261, Extended Power Uprate (ML091250564)
(2)
NRC letter to NextEra Energy Point Beach, LLC, dated March 31, 2010, Point Beach Nuclear Plant, Units I and 2 - Request for Additional lnformation from Containment and Ventilation Branch RE: Extended Power Uprate (TAC Nos. ME1 044 and ME1 045) (MLI 00780477)
(3)
NextEra Energy Point Beach, LLC letter to NRC, dated April 21, 2010, License Amendment Request 261, Extended Power Uprate, Response to Request for Additional lnformation (MLl01120064)
NextEra Energy Point Beach, LLC (NextEra) submitted License Amendment Request (LAR) 261 (Reference I ) to the NRC pursuant to 10 CFR 50.90. The proposed amendment would increase each unit's licensed thermal power level from 1540 megawatts thermal (MWt) to 1800 MWt, and revise the Technical Specifications to support operation at the increased thermal power level.
Via Reference (2), the NRC staff determined that additional information is required to enable the staff's continued review of the request. Reference (3) provided the NextEra response to the NRC staff's request for additional information. Enclosure I provides additional information to clarify the NextEra Response to Question 1 of Reference (3).
This letter contains no new Regulatory Commitments and no revisions to existing Regulatory Commitments.
The information contained in this letter does not alter the no significant hazards consideration contained in Reference (I) and continues to satisfy the criteria of 10 CFR 51.22 for categorical exclusion from the requirements of an environmental assessment.
NextEra Energy Point Beach, LLC, 6610 Nuclear Road, Two Rivers, WI 54241
Document Control Desk Page 2 In accordance with 10 CFR 50.91, a copy of this letter is being provided to the designated Wisconsin Official.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on June 10,2010.
Very truly yours, NextEra Energy Point Beach, LLC Enclosure cc:
Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW
ENCLOSURE I NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS I AND 2 LICENSE AMENDMENT REQUEST 261 EXTENDED POWER UPRATE RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION The NRC staff determined that additional information was required (Reference 1) to enable the Containment and Ventilation Branch to complete its review of License Amendment Request (LAR) 261, Extended Power Uprate (EPU) (Reference 2). By letter dated April 21, 201 0 (Reference 3), NextEra Energy Point Beach, LLC (NextEra) provided its response to the NRC staff's request. The following provides additional information to clarify the NextEra Response to Question I of Reference (3).
The following additional question was developed as a result the staff's review of the licensee's Extended Power Uprate (EPU) application for PBNP.
RAI SCVB-I (Clarification)
Verify that the containment accident recirculation fan housings are equipped with pressure relieving devices (air blast valves).
Response
Point Beach Nuclear Plant (PBNP) containment accident recirculation fan housings have pressure relieving devices (air blast valves) installed to prevent damage during a loss of coolant accident (LOCA) due to the pressure differential that occurs between the containment atmosphere and the lagging fan interior pressure. The blast valves are designed to limit the differential pressure to less than 2 psid based on a linear containment pressure buildup of 15 psilsec.
References
( 1 NRC letter to NextEra Energy Point Beach, LLC, dated March 31, 2010, Point Beach Nuclear Plant, Units 1 and 2 - Request for Additional lnformation from Containment and Ventilation Branch RE: Extended Power Uprate (TAC Nos. ME1 044 and ME1 045)
(MLI 00780477)
(2)
FPL Energy Point Beach, LLC letter to NRC, dated April 7,2009, License Amendment Request 261, Extended Power Uprate (ML091250564)
(3)