NRC 2005-0085, Spring 2004 Unit 2 (U2R27) Steam Generator Examination Report
| ML051940273 | |
| Person / Time | |
|---|---|
| Site: | Point Beach |
| Issue date: | 06/30/2005 |
| From: | Koehl D Nuclear Management Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| NRC 2005-0085 | |
| Download: ML051940273 (2) | |
Text
NM1 Committed to Nuclear Excellence Point Beach Nuclear Plant Operated by Nuclear Management Company, LLC June 30, 2005 NRC 2005-0085 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Point Beach Nuclear Plant, Unit 2 Docket 50-301 License No. DPR-27 Spring 2005 Unit 2 (U2R27) Steam Generator Examination Report In accordance with the requirements of Point Beach Nuclear Plant Technical Specification 5.6.8, "Steam Generator Tube Inspection Report,"
Nuclear Management Company, LLC (NMC), is submitting a summary of the spring 2005 Unit 2 (U2R27) steam generator inspections.
During U2R27, PBNP conducted no primary side steam generatorwork. The last primary side inspections were completed during U2R26 (October 2003). The steam generators have a C-1 rating. The C-I rating allows an interval of 40 months between steam generator inspections. The next primary side inspections will be during the fall 2006 refueling outage (U2R28).
During U2R27, secondary side visual inspections were performed in both steam generators at the top of the tubesheet of the peripheral tubes and in the no-tube lane (i.e., center lane where the blowdown line runs). These inspections were performed to search for potential loose parts. No loose parts were found, nor did the loose parts monitoring system detect any loose parts during the previous cycle. These inspections were precautionary to ensure good performance during the upcoming cycle.
This letter contains no new commitments and no revisions to existing commitments.
Dennis L. Koehl Site Vice-President, Point Beach Nuclear Plant Nuclear Management Company, LLC 6590 Nuclear Road
- Two Rivers, Wisconsin 54241 Telephone: 920.755.2321
-A-
Document Control Desk Page 2 cc:
Administrator, Region 111, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW