Letter Sequence Response to RAI |
|---|
|
Initiation
- Request, Request, Request, Request, Request, Request
- Acceptance...
- Supplement, Supplement, Supplement, Supplement, Supplement, Supplement
Results
Other: ML040980219, ML041960159, ML042660542, ML042730603, ML051650002, ML052630541, NRC 2004-0071, License Renewal Application Clarifications, NRC 2004-0085, License Renewal Application Revised Information, NRC 2004-0115, Recommended Corrections to NRC Audit Trip Report Regarding the Point Beach License Renewal Application, NRC 2005-0018, Confirmation of Information Verbally Provided to NRC Staff Regarding the Plant License Renewal Application, NRC 2005-0020, Amendment to the Point Beach Nuclear Plant License Renewal Application, NRC 2005-0031, . Information Regarding the Point Beach Nuclear Plant License Renewal Application, NRC 2005-0056, Response to Safety Evaluation Report (SER) with Open Items Regarding the Point Beach Nuclear Plant, License Renewal Application, NRC 2005-0074, Final Update Information Regarding the Point Beach Nuclear Plant License Renewal Application, NRC 2005-0105, Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application
|
MONTHYEARML0409802192004-04-0707 April 2004 Determination of Acceptability and Sufficiency for Docketing, Proposed Review Schedule, and Opportunity for a Hearing Regarding the Applications from Nuclear Management Company, LLC for Renewal of the Operating Licenses for Pt. Beach, Units Project stage: Other 05000301/LER-2004-002, Concerns with Diver Safety Results in Manual Reactor Trip2004-07-12012 July 2004 Concerns with Diver Safety Results in Manual Reactor Trip Project stage: Request NRC 2004-0071, License Renewal Application Clarifications2004-07-12012 July 2004 License Renewal Application Clarifications Project stage: Other ML0419601592004-07-12012 July 2004 License Renewal Application Clarifications - Point Beach Nuclear Plant, Units 1 and 2 LRA Project stage: Other ML0421103082004-07-27027 July 2004 RAI, License Renewal Application Project stage: RAI ML0421504312004-07-30030 July 2004 Request for Additional Information for the Review of the Point Beach Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: RAI NRC 2004-0086, Response to Request for Additional Information Regarding Sections 3.5 and 4.5 of the Point Beach Nuclear Plant License Renewal Application (TAC Nos. MC2099 and Mc 2100)2004-08-26026 August 2004 Response to Request for Additional Information Regarding Sections 3.5 and 4.5 of the Point Beach Nuclear Plant License Renewal Application (TAC Nos. MC2099 and Mc 2100) Project stage: Response to RAI ML0423600372004-08-26026 August 2004 Notice of Meeting with Industry on Risk Management Technical Specifications Project stage: Request NRC 2004-0083, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application2004-08-30030 August 2004 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Response to RAI NRC 2004-0084, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application2004-08-31031 August 2004 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Response to RAI NRC 2004-0085, License Renewal Application Revised Information2004-09-10010 September 2004 License Renewal Application Revised Information Project stage: Other ML0425700402004-09-10010 September 2004 Request for Additional Information for the Review of the Point Beach Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: RAI ML0426102832004-09-16016 September 2004 Request for Additional Information for the Review of the Point Beach Nuclear Plant, Units 1 and 2, License Renewal Application (AMP_XI.M33) Project stage: RAI ML0426801402004-09-23023 September 2004 Request for Additional Information for the Review of the Point Beach Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: RAI ML0426605422004-09-23023 September 2004 NRC Audit Trip Report on Point Beach License Renewal Scoping and Screening Methodology Audit from 06/21-24/2004 Project stage: Other ML0427306032004-09-30030 September 2004 Audit Trip Report Regarding the Nuclear Management Company, LLC, License Renewal Application for the Point Beach Nuclear Power Plant, Dated September 23, 2004 Project stage: Other NRC 2004-0100, Response to Request for Additional Information Regarding the Plant License Renewal Application2004-10-0808 October 2004 Response to Request for Additional Information Regarding the Plant License Renewal Application Project stage: Response to RAI ML0429406252004-10-15015 October 2004 10/1 Survey of Piping Plover Habitat on Point Beach Nuclear Plant Site Project stage: Request ML0429905342004-10-15015 October 2004 Response to Request for Additional Information Regarding the Plant License Renewal Application Project stage: Response to RAI ML0429905062004-10-21021 October 2004 Summary of Telephone Conference on August 19, 2004, Between the U.S. Nuclear Regulatory Commission and Nuclear Management Company, LLC, Concerning Draft Requests for Additional Information Pertaining to the Point Beach Nuclear Plant, Units Project stage: Draft RAI NRC 2004-0111, License Renewal Application Response to Request for Additional Information2004-10-25025 October 2004 License Renewal Application Response to Request for Additional Information Project stage: Response to RAI NRC 2004-0115, Recommended Corrections to NRC Audit Trip Report Regarding the Point Beach License Renewal Application2004-11-15015 November 2004 Recommended Corrections to NRC Audit Trip Report Regarding the Point Beach License Renewal Application Project stage: Other ML0435700172004-12-14014 December 2004 From NMC Re Technical Evaluation of Proposed Method of Class 3 Pipe Leak Operability Determinations Project stage: Request NRC 2004-0135, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application2004-12-14014 December 2004 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Response to RAI NRC 2004-0129, Response to Request for Additional Information Regarding the Point Beach License Renewal Application2004-12-17017 December 2004 Response to Request for Additional Information Regarding the Point Beach License Renewal Application Project stage: Response to RAI NRC 2004-0127, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application2004-12-21021 December 2004 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Response to RAI ML0500401782004-12-22022 December 2004 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Response to RAI NRC 2005-0006, Response to Request for Additional Information Regarding the Plant License Renewal Application2005-01-0606 January 2005 Response to Request for Additional Information Regarding the Plant License Renewal Application Project stage: Response to RAI NRC 2005-0005, Response to Request for Additional Information Regarding the Plant License Renewal Application2005-01-0707 January 2005 Response to Request for Additional Information Regarding the Plant License Renewal Application Project stage: Response to RAI NRC 2005-0007, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application2005-01-17017 January 2005 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Response to RAI NRC 2005-0009, Response to Request for Additional Information Regarding Plant License Renewal Application2005-01-21021 January 2005 Response to Request for Additional Information Regarding Plant License Renewal Application Project stage: Response to RAI ML0503402012005-01-25025 January 2005 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Response to RAI NRC 2005-0002, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant, Units 1 and 2, License Renewal Application2005-01-25025 January 2005 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: Response to RAI NRC 2005-0008, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant, Units 1 and 2 License Renewal Application2005-01-25025 January 2005 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant, Units 1 and 2 License Renewal Application Project stage: Response to RAI NRC 2005-0012, Response to Request for Additional Information Regarding Plant License Renewal Application2005-01-26026 January 2005 Response to Request for Additional Information Regarding Plant License Renewal Application Project stage: Response to RAI NRC 2005-0004, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application and Request for Withholding of Proprietary Information from Public Disclosure2005-01-28028 January 2005 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application and Request for Withholding of Proprietary Information from Public Disclosure Project stage: Response to RAI NRC 2005-0013, Response to Request for Additional Information Regarding the Plant License Renewal Application2005-01-28028 January 2005 Response to Request for Additional Information Regarding the Plant License Renewal Application Project stage: Response to RAI NRC 2005-0001, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application2005-01-31031 January 2005 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Response to RAI ML0503502452005-02-0404 February 2005 Notice of Meeting with Nuclear Management Company, LLC (NMC) to Discuss the License Renewal Application (LRA) for the Point Beach Nuclear Plant, Units 1 & 2 Project stage: Meeting NRC 2005-0018, Confirmation of Information Verbally Provided to NRC Staff Regarding the Plant License Renewal Application2005-02-0707 February 2005 Confirmation of Information Verbally Provided to NRC Staff Regarding the Plant License Renewal Application Project stage: Other NRC 2005-0020, Amendment to the Point Beach Nuclear Plant License Renewal Application2005-02-23023 February 2005 Amendment to the Point Beach Nuclear Plant License Renewal Application Project stage: Other NRC 2005-0019, Response to Request for Additional Information Regarding the Plant License Renewal Application2005-02-25025 February 2005 Response to Request for Additional Information Regarding the Plant License Renewal Application Project stage: Response to RAI NRC 2005-0024, Response to Request for Additional Information Regarding the License Renewal Application2005-03-0404 March 2005 Response to Request for Additional Information Regarding the License Renewal Application Project stage: Response to RAI NRC 2005-0031, . Information Regarding the Point Beach Nuclear Plant License Renewal Application2005-03-0404 March 2005 . Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Other NRC 2005-0029, Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application2005-03-15015 March 2005 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Response to RAI ML0507604632005-03-15015 March 2005 Letter from WE Energies to Fws Revising Piping Plover Monitoring Framework Project stage: Request NRC 2005-0026, Clarification to Information Regarding the Point Beach Nuclear Plant License Renewal Application2005-03-15015 March 2005 Clarification to Information Regarding the Point Beach Nuclear Plant License Renewal Application Project stage: Supplement ML0508900032005-03-30030 March 2005 Request for Additional Information for the Review of the Point Beach Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: RAI ML0509102172005-03-31031 March 2005 Request for Additional Information for the Review of the Point Beach Nuclear Plant, Units 1 and 2, License Renewal Application Project stage: RAI NRC 2005-0038, Response to Request for Additional Information Regarding the Plant License Renewal Application2005-04-0101 April 2005 Response to Request for Additional Information Regarding the Plant License Renewal Application Project stage: Response to RAI 2004-09-23
[Table View] |
Text
Nu El Committed to Nuclear Excellent" Point Beach Nuclear Plant Operated by Nuclear Management Company, LLC January 26, 2005 NRC 2005-0012 10 CFR 54 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 Point Beach Nuclear Plant, Units 1 and 2 Dockets 50-266 and 50-301 License Nos. DPR-24 and DPR-27 Response to Request for Additional Information Regarding the Point Beach Nuclear Plant License Renewal Application (TAC Nos. MC2099 and MC2100)
By letter dated February 25, 2004, Nuclear Management Company, LLC (NMC),
submitted the Point Beach Nuclear Plant (PBNP) Units 1 and 2 License Renewal Application (LRA). On January 10, 2005, the Nuclear Regulatory Commission (NRC) requested additional information regarding the Feedwater and Condensate System (Section 2.3.4.2 of the LRA). The enclosure to this letter contains NMC's response to the staff's questions.
Should you have any questions concerning this submittal, please contact Mr. James E. Knorr at (920) 755-6863.
This letter contains no new commitments and no revisions to existing commitments.
I declare under penalty of perjury that the forgoing is true and correct. Executed on January 26, 2005.
Dennis L. Koehl Site Vice-President, Point Beach Nuclear Plant Nuclear Management Company, LLC Enclosure 6590 Nuclear Road
- Two Rivers, Wisconsin 54241 Telephone: 920.755.2321 Ac)cf )
Document Desk Page 2 cc:
Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW
ENCLOSURE RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION REGARDING POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION The following information is provided in response to the Nuclear Regulatory Commission (NRC) staff's request for additional information (RAI) regarding the Point Beach Nuclear Plant (PBNP) License Renewal Application (LRA).
The NRC staff's question is restated below, with the Nuclear Management Company (NMC) response following.
Section 2.3.4 Steam and Power Conversion Systems 2.3.4.2 Feedwater and Condensate System Request for Additional Information (RAI)
RAI 2.3.4.2-4 In a letter dated November 16, 2004, the Nuclear Regulatory Commission (NRC) requested additional information regarding the Auxiliary Systems (LRA Section 2.3.3) and Steam and other Balance of Plant (BOP) Systems in LRA Sections 2.3.3 and 2.3.4 respectively. PBNP response to this request was submitted to the NRC in Nuclear Management Company, LLC letter dated December 22, 2004. The NRC review of the PBNP response to RAI 2.3.4.2-1 identified two follow-up questions regarding the scoping for the small bore branch piping from the NSR portion of the 16" main feed water header (FW) between the feed regulating valve and the downstream steam generator FW inlet check valve:
- 1.
Recognizing the NRC would not require a formal HELB evaluation be performed on piping 1-inch and less, did PBNP perform any evaluation (i.e., walkdown, etc.) to confirm that a break in the branch piping would not impact any safety related equipment in the immediate vicinity of the possible break location?
- 2.
Please discuss flooding associated with a failure in the branch piping and its impact on safety related equipment.
NMC Response:
- 1)
The section of main feedwater piping in question was included in scope to protect the safety-related (SR) (but non-Environmentally Qualified) feedwater flow transmitters (1/2FT-466, -467, -476, -477). Walkdowns were performed to verify that no high energy branch piping (including branch piping one-inch and less) was in proximity to the SR Page 1 of 2
transmitters where pipe whip or jet impingement could be a hazard. Additionally, the transmitters are in large open areas where the energy input from a failure of a small bore line off of this header Would not create a sufficiently harsh environment to affect the function of these transmitters.
- 2)
The SR feedwater flow transmitters in question are located on the 26' elevation for Unit 2 and the 39' elevation for Unit 1, and mounted about four feet off of the floor.
Any leakage from the main feedwater header branch connections at these elevations would cascade to lower elevations, and not affect the function of these transmitters nor any other safety-related equipment due to flooding.