NRC 2002-0014, January 2002 Monthly Operating Report for Point Beach, Units 1 & 2

From kanterella
(Redirected from NRC 2002-0014)
Jump to navigation Jump to search
January 2002 Monthly Operating Report for Point Beach, Units 1 & 2
ML020590444
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 02/15/2002
From: Webb T
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GL-97-002, NRC 2002-0014
Download: ML020590444 (14)


Text

{{#Wiki_filter:Kewaunee Nuclear Power Plant Point Beach Nuclear Plant N490 Highway 42 6610 Nuclear Road Kewaunee, WI 54216-9511 Two Rivers, WI 54241 920.388.2560 920.755.2321 NMC I" '> Committed to Nuclear Excellen Kewaunee / Point Beach Nuclear Operated by Nuclear Management Company, LLC NRC 2002-0014 GL 97-02 February 15, 2002 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Ladies/Gentlemen: DOCKETS 50-266 AND 50-301 POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 MONTHLY OPERATING REPORTS Attached are monthly operating reports for Units 1 and 2 of the Point Beach Nuclear Plant for the calendar month of January 2002. Sincerely, T.J Wb T. J. Webb Licensing Director KMD Attachment cc: J. D. Loock, PSCW NRC Region III NRC Senior Resident Inspector NRC Project Manager 1/NW\

                                                                                                 //

Docket 50-266 and 50-301 NRC-2002-0014 ATTACHMENT 1 Letter from Thomas J. Webb (NMC) To Document Control Desk (NRC) Dated February 15, 2002 Re: Monthly Operating Report - January 2002

OPERATING DATA REPORT DOCKET NO. 50-266 DATE: 02/01/02 COMPLETED BY: Kim M. Duescher TELEPHONE: 920-755-6,862 OPERATING STATUS

1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 1 NOTES
2. REPORTING PERIOD: January - 2002
3. LICENSED THERMAL POWER (MWT): 1,518.5
4. NAMEPLATING RATING (GROSS MWE): 537.7
5. DESIGN ELECTRICAL RATING (NET MWE): 515.0
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 530.0
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 510.0
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): N/A
10. REASONS FOR RESTRICTIONS, (IF ANY):

THIS MONTH YEAR TO DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 744.0 744.0 273,839.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 744.0 224,353.8
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 667.3
14. HOURS GENERATOR ONLINE 744.0 744.0 220,838.0
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 846.9
16. GROSS THERMAL ENERGY GENERATED (MWH) 1,128,527.0 1,128,527.0 315,130,978.0
17. GROSS ELECTRICAL ENERGY GENERATED 392,210.0 392,210.0 106,934,310.0
18. NET ELECTRICAL ENERGY GENERATED (MWH) 376,066.5 376,066.5 101,951,586.5
19. UNIT SERVICE FACTOR 100.0% 100.0% 80.6%
20. UNIT AVAILABILITY FACTOR 100.0% 100.0% 81.0%
21. UNIT CAPACITY FACTOR (USING MDC NET) 99.1% 99.1% 76.1%
22. UNIT CAPACITY FACTOR (USING DER NET) 98.1% 98.1% 74.7%
23. UNIT FORCED OUTAGE RATE 0.0% 0.0% 4.4%

DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED MAY 15, 1997

APPENDIX B UNIT SHUTDOWNS DOCKET NO. 50-266 UNIT NAME: Point Beach, Unit 1 DATE: 02/04/02 COMPLETED BY: Kim M. Duescher TELEPHONE: 755-6862 REPORTING PERIOD: January 2002 (Month/Year) NO. DATE TYPE DURATION REASON (1) METHOD OF CAUSE/CORRECTIVE ACTIONS F: FORCED (HOURS) SHUTTING S: SCHEDULED DOWN (2) COMMENTS N/A N/A N/A N/A N/A N/A (1) Reason (2) Method A. Equipment Failure (Explain) 1 Manual B. Maintenance or Test 2 Manual Trip/Scram C. Refueling 3 Automatic Trip/Scram D. Regulatory Restriction 4. Continuation E. Operator Training/license Examination F .Administrative 5. Other (Explain) G Operational Error (Explain) H .Other (Explain)

SUMMARY

Unit I average daily power for the month of December was 494.5 MWe. There were no Licensee Event Reports (LERs) submitted to the NRC. There were no Significant Operating Events.

POINT BEACH NUCLEAR PLANT DOCKET NO. 50-266 UNIT NAME: Point Beach, Unit 1 AVERAGE DAILY UNIT POWER LEVEL DATE: 02/01/02 MONTH JANUARY - 2002 COMPLETED BY: Kim M. Duescher TELEPHONE: 920-755-6862 AVERAGE AVERAGE AVERAGE DAILY DAILY DAILY POWER LEVEL POWER LEVEL POWER LEVEL DAY MWe NET DAY MWe NET DAY MWe NET 1 505 11 505 21 506 2 505 12 505 22 506 3 505 13 504 23 507 4 505 14 506 24 505 5 504 15 506 25 506 6 504 16 505 26 508 7 504 17 503 27 507 8 506 18 503 28 508 9 505 19 505 29 507 10 504 20 505 30 507 31 507

OPERATING DATA REPORT DOCKET NO. 50-301 DATE: 02/01/02 COMPLETED BY: Kim M. Duescher TELEPHONE: 920-755-6,862 OPERATING STATUS

1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 2 NOTES
2. REPORTING PERIOD: January - 2002
3. LICENSED THERMAL POWER (MWT): 1,518.5
4. NAMEPLATING RATING (GROSS MWE): 537.7
5. DESIGN ELECTRICAL RATING (NET MWE): 515.0
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 532.0
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 512.0
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): N/A
10. REASONS FOR RESTRICTIONS, (IF ANY):

THIS MONTH YEAR TO DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 744.0 744.0 258,624.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 744.0 218,525.6
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 233.9
14. HOURS GENERATOR ONLINE 744.0 744.0 215,598.2
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 302.2
16. GROSS THERMAL ENERGY GENERATED (MWH) 1,128,657.0 1,128,657.0 311,177,074.0
17. GROSS ELECTRICAL ENERGY GENERATED 391,090.0 391,090.0 106,119,130.0
18. NET ELECTRICAL ENERGY GENERATED (MWH) 374,962.5 374,962.5 101,158,469.5
19. UNIT SERVICE FACTOR 100.0% 100.0% 83.4%
20. UNIT AVAILABILITY FACTOR 100.0% 100.0% 83.5%
21. UNIT CAPACITY FACTOR (USING MDC NET) 98.4% 98.4% 79.8%
22. UNIT CAPACITY FACTOR (USING DER NET) 97.9% 97.9% 78.4%
23. UNIT FORCED OUTAGE RATE 0.0% 0.0% 2.2%

DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED MAY 15, 1997

APPENDIX B UNIT SHUTDOWNS DOCKET NO. 50-301 UNIT NAME: Point Beach, Unit 2 DATE: 02/04/02 COMPLETED BY: Kim M. Duescher TELEPHONE: 755-6862 REPORTING PERIOD: January 2002 (Month/Year) NO. DATE TYPE DURATION REASON (1) METHOD OF CAUSE/CORRECTIVE ACTIONS F: FORCED (HOURS) SHUTTING S: SCHEDULED DOWN (2) COMMENTS N/A N/A N/A N/A N/A N/A (1) Reason (2) Method A. Equipment Failure (Explain) 1 Manual B. Maintenance or Test 2 Manual Trip/Scram C. Refueling 3 Automatic Trip/Scram D. Regulatory Restriction 4. Continuation E. Operator Training/license Examination F .Administrative 5. Other (Explain) G .Operational Error (Explain) H Other (Explain)

SUMMARY

Unit 2 average daily power for the month of December was 499.7MWe. There were no Licensee Event Reports (LERs) submitted to the NRC. There were no Significant Operating Events.

POINT BEACH NUCLEAR PLANT DOCKET NO. 50-301 UNIT NAME: Point Beach, Unit 2 AVERAGE DAILY UNIT POWER LEVEL DATE: 02/01/02 MONTH JANUARY - 2002 COMPLETED BY: Kim M. Duescher TELEPHONE: 920-755-6862 AVERAGE AVERAGE AVERAGE DAILY DAILY DAILY POWER LEVEL POWER LEVEL POWER LEVEL DAY MWe NET DAY MWe NET DAY MWe NET 1 507 11 504 21 504 2 499 12 504 22 510 3 502 13 503 23 501 4 502 14 505 24 504 5 503 15 504 25 505 6 503 16 504 26 506 7 503 17 501 27 505 8 505 18 502 28 506 9 504 19 504 29 505 10 503 20 504 30 506 31 505

POINT BEACH NUCLEAR PLANT OPERATING

SUMMARY

REPORT UNIT 1 - JANUARY 2002 ELECTRICAL UNITS MONTH YEAR CUMULATIVE GROSS GENERATION MWH 392,210.0 392,210.0 106,934,310.0 TOTAL STATION SERVICE MWH 16,143.5 16,143.5 4,982,723.5 NET OUTPUT MWH 376,066.5 376,066.5 101,951,586.5 AVG. GROSS GENERATION FOR MONTH MWH 527.2 527.2 390.5 AVG. GROSS GENERATION RUNNING MWH 527.2 527.2 484.2 TOTAL STATION SERVICE/GROSS GEN. 4.1% 4.1% 4.7% HOURS OF GENERATION HRS 744.0 744.0 220,838.0 PLANT PERFORMANCE UNITS MONTH YEAR CUMULATIVE NET PLANT EFFICIENCY 33.32% 33.32% 32.35% NET PLANT HEAT RATE BTU/KWH 10,241.2 10,241.2 10,548.8 NUMBER OF DAYS OF OPERATION DAYS 31 31 10,083 UNIT NET CAPACITY FACTOR 99.1% 99.1% 76.1% UNIT SERVICE FACTOR 100.0% 100.0% 80.6% SCHEDULED OUTAGES 0 0 126 FORCED OUTAGES 0 0 73 FORCED OUTAGE HOURS HRS 0.0 0.0 10,227.1 UNIT FORCED OUTAGE RATE 0.0% 0.0% 4.4% NUCLEAR UNITS MONTH YEAR CUMULATIVE HOURS CRITICAL HRS 744.0 744.0 224,353.8 TOTAL HOURS POSSIBLE HRS 744.0 744.0 273,839.0 INADVERTANT REACTOR TRIPS 0 0 57 DURATION OF REACTOR DOWN TIME HRS 0.0 0.0 49,569.2 REACTOR CAPACITY FACTOR 99.9% 99.9% 75.8% REACTOR SERVICE FACTOR 100.0% 100.0% 81.9% THERMAL POWER GENERATED MWTHR 1,128,527.0 1,128,527.0 315,130,978.0 THERMAL POWER GENERATED THIS FUEL CYCLE MWTHR 8,826,308.0

POINT BEACH NUCLEAR PLANT OPERATING

SUMMARY

REPORT UNIT 2 - JANUARY 2002 ELECTRICAL UNITS MONTH YEAR CUMULATIVE GROSS GENERATION MWH 391,090.0 391,090.0 106,119,130.0 TOTAL STATION SERVICE MWH 16,127.5 16,127.5 4,960,660.5 NET OUTPUT MWH 374,962.5 374,962.5 101,158,469.5 AVG. GROSS GENERATION FOR MONTH MWH 525.7 525.7 410.3 AVG. GROSS GENERATION RUNNING MWH 525.7 525.7 492.2 TOTAL STATION SERVICE/GROSS GEN. 4.1% 4.1% 4.7% HOURS OF GENERATION HRS 744.0 744.0 215,598.2 PLANT PERFORMANCE UNITS MONTH YEAR CUMULATIVE NET PLANT EFFICIENCY 33.22% 33.22% 32.51% NET PLANT HEAT RATE BTU/KWH 10,272.6 10,272.6 10,498.1 NUMBER OF DAYS OF OPERATION DAYS 31 31 9,121 UNIT NET CAPACITY FACTOR 98.4% 98.4% 79.8% UNIT SERVICE FACTOR 100.0% 100.0% 83.4% SCHEDULED OUTAGES 0 0 92 FORCED OUTAGES 0 0 58 FORCED OUTAGE HOURS HRS 0.0 0.0 4,829.3 UNIT FORCED OUTAGE RATE 0.0% 0.0% 2.2% NUCLEAR UNITS MONTH YEAR CUMULATIVE HOURS CRITICAL HRS 744.0 744.0 218,525.6 TOTAL HOURS POSSIBLE HRS 744.0 744.0 258,624.0 INADVERTANT REACTOR TRIPS 0 0 50 DURATION OF REACTOR DOWN TIME HRS 0.0 0.0 40,098.4 REACTOR CAPACITY FACTOR 99.9% 99.9% 79.3% REACTOR SERVICE FACTOR 100.0% 100.0% 84.5% THERMAL POWER GENERATED MWTHR 1,128,657.0 1,128,657.0 311,177,074.0 THERMAL POWER GENERATED THIS FUEL CYCLE MWTHR 14,490,181.0

POINT BEACH SHIFT OPERATIONAL DATA

SUMMARY

January, 2002 Unit 1 Unit22 DAY j Gen X02 X04 X08 X27 Net MWhr Avg MWe Gen X02 X04 X08 X27 Net MWhr Ava MWe  ! 1 12650.0 476.0 39.0 1.0 6.0 12128.0 505.3 12700.0 473.0 41.0 1.0 6.0 12179.0 507.5 2 12650.0 478.0 37.0 1.0 6.0 12128.0 505.3 12500.0 474.0 42.0 1.0 6.0 11977.0 499.0 3 12650.0 478.0 38.0 1.0 6.5 12126.5 505.3 12570.0 473.0 40.0 1.0 6.5 12049.5 502.1 4 12650.0 479.0 38.0 1.5 6.0 12125.5 505.2 12580.0 474.0 39.0 1.5 6.0 12059.5 502.5 5 12610.0 477.0 37.0 0.5 5.5 12090.0 503.8 12590.0 475.0 38.0 0.5 5.5 12071.0 503.0 6 12620.0 476.0 36.0 1.0 5.5 12101.5 504.2 12590.0 482.0 38.0 1.0 5.5 12063.5 502.6 7 12630.0 477.0 39.0 1.0 6.0 12107.0 504.5 12580.0 463.0 37.0 1.0 6.0 12073.0 503.0 8 12670.0 476.0 38.0 1.0 5.5 12149.5 506.2 12640.0 473.0 39.0 1.0 5.5 12121.5 505.1 9 12650.0 476.0 38.0 1.0 5.5 12129.5 505.4 12610.0 474.0 36.0 1.0 5.5 12093.5 503.9 i10 12620.0 476.0 37.0 1.0 5.0 12101.0 504.2 12580.0 473.0 37.0 1.0 5.0 12064.0 502.7 i11 12640.0 476.0 38.0 1.0 5.5 12119.5 505.0 12610.0 473.0 37.0 1.0 5.5 12093.5 503.9 12 12640.0 477.0 37.0 1.0 5.5 12119.5 505.0 12620.0 473.0 36.0 1.0 5.5 12104.5 504.4 13 12620.0 476.0 38.0 1.0 5.0 12100.0 504.2 12590.0 473.0 37.0 1.0 5.0 12074.0 503.1 14 12670.0 479.0 38.0 1.0 5.5 12146.5 506.1 12640.0 474.0 37.0 1.0 5.5 12122.5 505.1 15 12670.0 478.0 37.0 1.0 6.0 12148.0 506.2 12620.0 475.0 37.0 1.0 6.0 12101.0 504.2 16 12640.0 481.0 36.0 1.0 5.5 12116.5 504.9 12610.0 475.0 39.0 1.0 5.5 12089.5 503.7 17 12580.0 479.0 33.0 1.5 6.5 12060.0 502.5 12560.0 474.0 44.0 1.5 6.5 12034.0 501.4 18 12590.0 482.0 34.0 1.0 6.5 12066.5 502.8 12580.0 476.0 45.0 1.0 6.5 12051.5 502.1 19 12630.0 479.0 34.0 1.0 6.0 12110.0 504.6 12610.0 474.0 43.0 1.0 6.0 12086.0 503.6 20 12640.0 479.0 32.0 1.0 5.5 12122.5 505.1 12620.0 476.0 43.0 1.0 5.5 12094.5 503.9 21 12660.0 480.0 31.0 1.0 6.0 12142.0 505.9 12630.0 477.0 42.0 1.0 6.0 12104.0 504.3 22 12660.0 479.0 33.0 1.0 5.5 12141.5 505.9 12760.0 476.0 42.0 1.0 5.5 12235.5 509.8 23 12680.0 477.0 32.0 0.5 5.5 12165.0 506.9 12550.0 476.0 39.0 0.5 5.5 12029.0 501.2 24 12640.0 480.0 33.0 1.0 6.0 12120.0 505.0 12610.0 476.0 43.0 1.0 6.0 12084.0 503.5 25 12670.0 479.0 34.0 1.5 5.5 12150.0 506.2 12650.0 476.0 40.0 1.5 5.5 12127.0 505.3 26 12700.0 476.0 36.0 0.5 5.0 12182.5 507.6 12660.0 473.0 46.0 0.5 5.0 12135.5 505.6 27 12690.0 476.0 33.0 1.0 5.0 12175.0 507.3 12620.0 473.0 26.0 1.0 5.0 12115.0 504.8 28 12710.0 479.0 37.0 0.5 5.5 12188.0 507.8 12670.0 476.0 36.0 0.5 5.5 12152.0 506.3 29 12700.0 480.0 38.0 1.0 6.0 12175.0 507.3 12660.0 486.0 38.0 1.0 6.0 12129.0 505.4 30 12690.0 480.0 37.0 1.5 6.5 12165.0 506.9 12650.0 467.0 38.0 1.5 6.5 12137.0 505.7 31 12690.0 480.0 37.0 0.5 5.5 12167.0 507.0 12630.0 475.0 37.0 0.5 5.5 12112.0 504.7 MnWT.TT.V MnMAPT.0 - rTT'T1T 1 MONTHLY TOTALS - UNIT 2 Gross Generation: 392,210.0 MWhr Gross Generation: 391,090.0 MWhr Total Station Service: 16,143.5 MWhr Total Station Service: 16,127.5 MWhr Net Generation: 376,066.5 MWhr Net Generation: 374,962.5 MWhr Average Daily Power: 505.5 MWe Average Daily Power: 504.0 MWe

PANP UNIT 1 CYCLE 27 JANUARY 2002 - BURNUP SYNOPSIS & REFUELING SCHEDULING DATA Gol-ý BURNUP DATA IN MWD/MTU THIS TOTAL PERIOD CYCLE 27 TOTAL CYCLE AVERAGE 1064. 8320. 28758. REGION AVERAGE 126B 384. 2896. 38882. 127A 327. 2426. 43808. 127B 746. 5719. 45661. 128A 1253. 9955. 31872. 128B 1359. 10845. 30771. 129A 1438. 11076. 11076. 129B 1268. 9891. 9891. CORE MWTHR 1128527. 8826308. 30506707. DAYS IN PERIOD/CYCLE 31 263 POWER FACTOR 99.9% 92.1% "* BASED ON NUMBER OF DAYS IN PERIOD OR CYCLE. PROJECTED EOL BURNUP 16042. 15439. "* BASED ON DAYS REMAINING UNTIL REFUELING DATE ASSUMING PERIOD OR CYCLE POWER FACTOR

                                           --------. REFUELING*SCHEDULE  DATA SCHEDULED REFUELING DATE    9/14/2002 DESIGN     TEN PPM      NOTE: DESIGN BURNUP IS THE END OF CYCLE BURNUP THAT WAS BURNUP FOR CYCLE   27 (MWD/MTU)                16285.      16200.            USED IN THE FINAL CORE DESIGN. TEN PPM BURNUP IS REMAINING EFFECTIVE FULL POWER DAYS            231.8       229.4             THE CORE AVERAGE BURNUP PROJECTED AT TEN PPM BORON FRACTION OF CYCLE LIFE EXPENDED                 51.1%       51.4%            BASED ON CURRENT BORON FOLLOW RESULTS.

ESTIMATED DATE FOR DESIGN AND TEN PPM BURNUPS ASSUMING VARIOUS POWER FACTORS POWER FACTOR 100.% 95.% 90.% 85.% 80.% 75.% 70.% 65.% TEN PPM BORON DATE 9/18/2002 9/:30/2002 10/13/2002 10/28/2002 11/14/2002 12/ 3/2002 12/25/2002 1/19/2003 DESIGN BURNUP DATE 9/20/2002 10/ 3/2002 10/16/2002 10/31/2002 11/17/2002 12/ 7/2002 12/29/2002 1/23/2003

PBNP UNIT 2 CYCLE 25 JANUARY 2002 BURNUP SYNOPSIS & REFUELING SCHEDULING DATA BURNUP DATA IN MWD/MTU THIS TOTAL PERIOD CYCLE 25 TOTAL CYCLE AVERAGE 1057. 13569. 32725. REGION AVERAGE 223D 341. 3976. 47735. 224A 303. 3541. 38846. 225A 703. 8760. 37802. 225B 440. 5295. 42963. 226A 1127. 14456. 42667. 226B 1277. 16736. 40315. 227A 1360. 17479. 17479. 227B 1187. 15355. 15355. CORE MWTHR 1128657. 14490181. 34 i946008. DAYS IN PERIOD/CYCLE 31 411 POWER FACTOR 100.0% 96.7%

  • BASED ON NUMBER OF DAYS IN PERIOD OR CYCLE.

PROJECTED EOL BURNUP 15992. 15913.

  • BASED ON DAYS REMAINING UNTIL REFUELING DATE ASSUMING PERIOD OR CYCLE POWER FACTOR REFUELINGSSCHEDULE DATA SCHEDULED REFUELING DATE 4/13/2002 DESIGN TEN PPM NOTE: DESIGN BURNUP IS THE END OF CYCLE BURNUP THAT WAS BURNUP FOR CYCLE 25 (MWD/MTU) 16660. 16660. USED IN THE FINAL CORE DESIGN. TEN PPM BURNUP IS REMAINING EFFECTIVE FULL POWER DAYS 90.6 90.6 THE CORE AVERAGE BURNUP PROJECTED AT TEN PPM BORON FRACTION OF CYCLE LIFE EXPENDED 81.4% 81.4% BASED ON CURRENT BORON FOLLOW RESULTS.

ESTIMATED DATE FOR DESIGN AND TEN PPM BURNUPS ASSUMING VARIOUS POWER FACTORS POWER FACTOR 100.% 95.% 90.% 85.% 80.% 75.% 70.% 65.% TEN PPM BORON DATE S/ 2/2002 5/ 7/2002 5 /12/2002 5/18/2002 5/25/2002 6/ 1/2002 6/10/2002 6/20/2002 DESIGN BURNUP DATE 5/ 2/2002 S/ 7/2002 5, /12/2002 5/18/2002 5/25/2002 6/ 1/2002 6/10/2002 6/20/2002

Page 1 of 1 Shift Operation Data January,2002 Unit 1 IUnit2 X0 x02 x04 Xo8X27 G0S Gen IGo Aux Z Day HrslGe] [--- 24 55750949.0217. Gen 74116.0181616.0160142.016329.01 120.015683.0 15849.0 W 24 564.0925. 425075366.0 82090.0 60184.0 6331 0 132.0 5683.0 5865.0 FY11I 24 1l8050I9730l225.I76623.o1182563. 160224.0 6333 01145 01 5683.0 58820o 4 24 19 24291.0 77881.0 83037.0 60263.0 6336.0 157.0 5683.0 5896.0 W 24 D651. 679024328.0179140.0 83512.0 60301.0 6337.0 168.0 5683.0 15909.0 W61241]61793.0 97185.0 24364.0 80399.0 83994.0 60339.0 6339.0 179.0 .5683.0 !5925.0 [Ull W-- 241630560 0197662. 0124403.01181657. 24-164323.01198138. 0124441.01182921. 0184457. 0184930. 0160376.0116341.011191.0115683 0160415.0116343.011202. 015683 0 11594o00 0 15953.0 Il-'il 165588.01198614.01124479.01184182.01185404.0[160451.016345.011213.0115683. 0 I5975.0 24 15963 0 10-]241166850.01199090.01124516.01185440.01185877.01160488.0116347.011223.0115683-0 11* 24 [68114.0l[99566.01124554.0l[86701.0[186350.01160525.01163490o12340o156830o 15988.0 12 24 69378.0]43.0 24591.0l87963.0[86823.0160561.0[6351.0[2450 5683.0 6001.0 13 124[]70640.011519.0 [24629.01189222.0[[87296.0ll60598.0[16353.0[[255.05683.0 16015.0[ 14 124[[71907.0 1998.0 124667.0[190486.01187770.0ll60635.0116355.0[[266.0115683.0 16030.0 1i5- 24 [73174,0111476.0 l24704.01191748.0[188245.0l[60672.01[6357.0[278.015683.0 l6044.0 [17 24 l75696.0[[2436.0 [24773.0 925. 9140 05506362.0[302.0 5686.0 [6077.0 18 4 769550 29180 24807.0 952. 89670.0 60800.0 6364031510 56860 60990 F19 24 78280 3397.0 24841.0 968. 90144.060843.0 63660 3270 56860 6118.0 20* 24 79482.0 3876.0 124873.0 984. 90620.0 [60886.0 6368.0 338.0 5686.0 [6133.0 22* 24 [82014.0 4350 497. 55.'957.0607006372.011361.0115686.0 [6160.0 F 121 F24 1183282.05 0 6 84 1 6373.0 372.0 5686.0 6172.0 24 j24 ][454.015. 250.03010922.0605. 6375.0 384.0 5686.0 6186.0 25- 4 88130 671. 2536.436.09301. 619.0678.0 395.0 56860 16197.0 262487830 677. 502. 5320 344. 1806379.0 405.0 56860 [6207.0 27- 4 832.[723i 210.0689.093470 1406381.0 415.0 5680 [62180 F24][E* 28 2489230 70.025420 16,094230

                                                                                    *I*

12006382.01426.0156860o 2*. [6232.01

         - I-24 0930             8120      258.0 9270 990.             628.      34.0 438.0 56860        [649.0   1 i*3 -I4 26.0 86.0                  227.      0920 937.             12606387.0i1451.015686.0      [16264,0 i I 3124142.343.02554. 1155.09581.06133.06388.0            462.0 56860   ~29 https://www.surfn-nuclear.com/wepcol/cgi-binldivers/generation/generation-meter.cgi?action=                        2/1/2002}}

Text

{{#Wiki_filter:Kewaunee Nuclear Power Plant Point Beach Nuclear Plant N490 Highway 42 6610 Nuclear Road Kewaunee, WI 54216-9511 Two Rivers, WI 54241 920.388.2560 920.755.2321 NMC I" '> Committed to Nuclear Excellen Kewaunee / Point Beach Nuclear Operated by Nuclear Management Company, LLC NRC 2002-0014 GL 97-02 February 15, 2002 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555 Ladies/Gentlemen: DOCKETS 50-266 AND 50-301 POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 MONTHLY OPERATING REPORTS Attached are monthly operating reports for Units 1 and 2 of the Point Beach Nuclear Plant for the calendar month of January 2002. Sincerely, T.J Wb T. J. Webb Licensing Director KMD Attachment cc: J. D. Loock, PSCW NRC Region III NRC Senior Resident Inspector NRC Project Manager 1/NW\

                                                                                                 //

Docket 50-266 and 50-301 NRC-2002-0014 ATTACHMENT 1 Letter from Thomas J. Webb (NMC) To Document Control Desk (NRC) Dated February 15, 2002 Re: Monthly Operating Report - January 2002

OPERATING DATA REPORT DOCKET NO. 50-266 DATE: 02/01/02 COMPLETED BY: Kim M. Duescher TELEPHONE: 920-755-6,862 OPERATING STATUS

1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 1 NOTES
2. REPORTING PERIOD: January - 2002
3. LICENSED THERMAL POWER (MWT): 1,518.5
4. NAMEPLATING RATING (GROSS MWE): 537.7
5. DESIGN ELECTRICAL RATING (NET MWE): 515.0
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 530.0
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 510.0
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): N/A
10. REASONS FOR RESTRICTIONS, (IF ANY):

THIS MONTH YEAR TO DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 744.0 744.0 273,839.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 744.0 224,353.8
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 667.3
14. HOURS GENERATOR ONLINE 744.0 744.0 220,838.0
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 846.9
16. GROSS THERMAL ENERGY GENERATED (MWH) 1,128,527.0 1,128,527.0 315,130,978.0
17. GROSS ELECTRICAL ENERGY GENERATED 392,210.0 392,210.0 106,934,310.0
18. NET ELECTRICAL ENERGY GENERATED (MWH) 376,066.5 376,066.5 101,951,586.5
19. UNIT SERVICE FACTOR 100.0% 100.0% 80.6%
20. UNIT AVAILABILITY FACTOR 100.0% 100.0% 81.0%
21. UNIT CAPACITY FACTOR (USING MDC NET) 99.1% 99.1% 76.1%
22. UNIT CAPACITY FACTOR (USING DER NET) 98.1% 98.1% 74.7%
23. UNIT FORCED OUTAGE RATE 0.0% 0.0% 4.4%

DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED MAY 15, 1997

APPENDIX B UNIT SHUTDOWNS DOCKET NO. 50-266 UNIT NAME: Point Beach, Unit 1 DATE: 02/04/02 COMPLETED BY: Kim M. Duescher TELEPHONE: 755-6862 REPORTING PERIOD: January 2002 (Month/Year) NO. DATE TYPE DURATION REASON (1) METHOD OF CAUSE/CORRECTIVE ACTIONS F: FORCED (HOURS) SHUTTING S: SCHEDULED DOWN (2) COMMENTS N/A N/A N/A N/A N/A N/A (1) Reason (2) Method A. Equipment Failure (Explain) 1 Manual B. Maintenance or Test 2 Manual Trip/Scram C. Refueling 3 Automatic Trip/Scram D. Regulatory Restriction 4. Continuation E. Operator Training/license Examination F .Administrative 5. Other (Explain) G Operational Error (Explain) H .Other (Explain)

SUMMARY

Unit I average daily power for the month of December was 494.5 MWe. There were no Licensee Event Reports (LERs) submitted to the NRC. There were no Significant Operating Events.

POINT BEACH NUCLEAR PLANT DOCKET NO. 50-266 UNIT NAME: Point Beach, Unit 1 AVERAGE DAILY UNIT POWER LEVEL DATE: 02/01/02 MONTH JANUARY - 2002 COMPLETED BY: Kim M. Duescher TELEPHONE: 920-755-6862 AVERAGE AVERAGE AVERAGE DAILY DAILY DAILY POWER LEVEL POWER LEVEL POWER LEVEL DAY MWe NET DAY MWe NET DAY MWe NET 1 505 11 505 21 506 2 505 12 505 22 506 3 505 13 504 23 507 4 505 14 506 24 505 5 504 15 506 25 506 6 504 16 505 26 508 7 504 17 503 27 507 8 506 18 503 28 508 9 505 19 505 29 507 10 504 20 505 30 507 31 507

OPERATING DATA REPORT DOCKET NO. 50-301 DATE: 02/01/02 COMPLETED BY: Kim M. Duescher TELEPHONE: 920-755-6,862 OPERATING STATUS

1. UNIT NAME: POINT BEACH NUCLEAR PLANT - UNIT 2 NOTES
2. REPORTING PERIOD: January - 2002
3. LICENSED THERMAL POWER (MWT): 1,518.5
4. NAMEPLATING RATING (GROSS MWE): 537.7
5. DESIGN ELECTRICAL RATING (NET MWE): 515.0
6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 532.0
7. MAXIMUM DEPENDABLE CAPACITY (NET MWE): 512.0
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): N/A
10. REASONS FOR RESTRICTIONS, (IF ANY):

THIS MONTH YEAR TO DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 744.0 744.0 258,624.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 744.0 218,525.6
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 233.9
14. HOURS GENERATOR ONLINE 744.0 744.0 215,598.2
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 302.2
16. GROSS THERMAL ENERGY GENERATED (MWH) 1,128,657.0 1,128,657.0 311,177,074.0
17. GROSS ELECTRICAL ENERGY GENERATED 391,090.0 391,090.0 106,119,130.0
18. NET ELECTRICAL ENERGY GENERATED (MWH) 374,962.5 374,962.5 101,158,469.5
19. UNIT SERVICE FACTOR 100.0% 100.0% 83.4%
20. UNIT AVAILABILITY FACTOR 100.0% 100.0% 83.5%
21. UNIT CAPACITY FACTOR (USING MDC NET) 98.4% 98.4% 79.8%
22. UNIT CAPACITY FACTOR (USING DER NET) 97.9% 97.9% 78.4%
23. UNIT FORCED OUTAGE RATE 0.0% 0.0% 2.2%

DATA REPORTED AND FACTORS CALCULATED AS REQUESTED IN NRC LETTER DATED MAY 15, 1997

APPENDIX B UNIT SHUTDOWNS DOCKET NO. 50-301 UNIT NAME: Point Beach, Unit 2 DATE: 02/04/02 COMPLETED BY: Kim M. Duescher TELEPHONE: 755-6862 REPORTING PERIOD: January 2002 (Month/Year) NO. DATE TYPE DURATION REASON (1) METHOD OF CAUSE/CORRECTIVE ACTIONS F: FORCED (HOURS) SHUTTING S: SCHEDULED DOWN (2) COMMENTS N/A N/A N/A N/A N/A N/A (1) Reason (2) Method A. Equipment Failure (Explain) 1 Manual B. Maintenance or Test 2 Manual Trip/Scram C. Refueling 3 Automatic Trip/Scram D. Regulatory Restriction 4. Continuation E. Operator Training/license Examination F .Administrative 5. Other (Explain) G .Operational Error (Explain) H Other (Explain)

SUMMARY

Unit 2 average daily power for the month of December was 499.7MWe. There were no Licensee Event Reports (LERs) submitted to the NRC. There were no Significant Operating Events.

POINT BEACH NUCLEAR PLANT DOCKET NO. 50-301 UNIT NAME: Point Beach, Unit 2 AVERAGE DAILY UNIT POWER LEVEL DATE: 02/01/02 MONTH JANUARY - 2002 COMPLETED BY: Kim M. Duescher TELEPHONE: 920-755-6862 AVERAGE AVERAGE AVERAGE DAILY DAILY DAILY POWER LEVEL POWER LEVEL POWER LEVEL DAY MWe NET DAY MWe NET DAY MWe NET 1 507 11 504 21 504 2 499 12 504 22 510 3 502 13 503 23 501 4 502 14 505 24 504 5 503 15 504 25 505 6 503 16 504 26 506 7 503 17 501 27 505 8 505 18 502 28 506 9 504 19 504 29 505 10 503 20 504 30 506 31 505

POINT BEACH NUCLEAR PLANT OPERATING

SUMMARY

REPORT UNIT 1 - JANUARY 2002 ELECTRICAL UNITS MONTH YEAR CUMULATIVE GROSS GENERATION MWH 392,210.0 392,210.0 106,934,310.0 TOTAL STATION SERVICE MWH 16,143.5 16,143.5 4,982,723.5 NET OUTPUT MWH 376,066.5 376,066.5 101,951,586.5 AVG. GROSS GENERATION FOR MONTH MWH 527.2 527.2 390.5 AVG. GROSS GENERATION RUNNING MWH 527.2 527.2 484.2 TOTAL STATION SERVICE/GROSS GEN. 4.1% 4.1% 4.7% HOURS OF GENERATION HRS 744.0 744.0 220,838.0 PLANT PERFORMANCE UNITS MONTH YEAR CUMULATIVE NET PLANT EFFICIENCY 33.32% 33.32% 32.35% NET PLANT HEAT RATE BTU/KWH 10,241.2 10,241.2 10,548.8 NUMBER OF DAYS OF OPERATION DAYS 31 31 10,083 UNIT NET CAPACITY FACTOR 99.1% 99.1% 76.1% UNIT SERVICE FACTOR 100.0% 100.0% 80.6% SCHEDULED OUTAGES 0 0 126 FORCED OUTAGES 0 0 73 FORCED OUTAGE HOURS HRS 0.0 0.0 10,227.1 UNIT FORCED OUTAGE RATE 0.0% 0.0% 4.4% NUCLEAR UNITS MONTH YEAR CUMULATIVE HOURS CRITICAL HRS 744.0 744.0 224,353.8 TOTAL HOURS POSSIBLE HRS 744.0 744.0 273,839.0 INADVERTANT REACTOR TRIPS 0 0 57 DURATION OF REACTOR DOWN TIME HRS 0.0 0.0 49,569.2 REACTOR CAPACITY FACTOR 99.9% 99.9% 75.8% REACTOR SERVICE FACTOR 100.0% 100.0% 81.9% THERMAL POWER GENERATED MWTHR 1,128,527.0 1,128,527.0 315,130,978.0 THERMAL POWER GENERATED THIS FUEL CYCLE MWTHR 8,826,308.0

POINT BEACH NUCLEAR PLANT OPERATING

SUMMARY

REPORT UNIT 2 - JANUARY 2002 ELECTRICAL UNITS MONTH YEAR CUMULATIVE GROSS GENERATION MWH 391,090.0 391,090.0 106,119,130.0 TOTAL STATION SERVICE MWH 16,127.5 16,127.5 4,960,660.5 NET OUTPUT MWH 374,962.5 374,962.5 101,158,469.5 AVG. GROSS GENERATION FOR MONTH MWH 525.7 525.7 410.3 AVG. GROSS GENERATION RUNNING MWH 525.7 525.7 492.2 TOTAL STATION SERVICE/GROSS GEN. 4.1% 4.1% 4.7% HOURS OF GENERATION HRS 744.0 744.0 215,598.2 PLANT PERFORMANCE UNITS MONTH YEAR CUMULATIVE NET PLANT EFFICIENCY 33.22% 33.22% 32.51% NET PLANT HEAT RATE BTU/KWH 10,272.6 10,272.6 10,498.1 NUMBER OF DAYS OF OPERATION DAYS 31 31 9,121 UNIT NET CAPACITY FACTOR 98.4% 98.4% 79.8% UNIT SERVICE FACTOR 100.0% 100.0% 83.4% SCHEDULED OUTAGES 0 0 92 FORCED OUTAGES 0 0 58 FORCED OUTAGE HOURS HRS 0.0 0.0 4,829.3 UNIT FORCED OUTAGE RATE 0.0% 0.0% 2.2% NUCLEAR UNITS MONTH YEAR CUMULATIVE HOURS CRITICAL HRS 744.0 744.0 218,525.6 TOTAL HOURS POSSIBLE HRS 744.0 744.0 258,624.0 INADVERTANT REACTOR TRIPS 0 0 50 DURATION OF REACTOR DOWN TIME HRS 0.0 0.0 40,098.4 REACTOR CAPACITY FACTOR 99.9% 99.9% 79.3% REACTOR SERVICE FACTOR 100.0% 100.0% 84.5% THERMAL POWER GENERATED MWTHR 1,128,657.0 1,128,657.0 311,177,074.0 THERMAL POWER GENERATED THIS FUEL CYCLE MWTHR 14,490,181.0

POINT BEACH SHIFT OPERATIONAL DATA

SUMMARY

January, 2002 Unit 1 Unit22 DAY j Gen X02 X04 X08 X27 Net MWhr Avg MWe Gen X02 X04 X08 X27 Net MWhr Ava MWe  ! 1 12650.0 476.0 39.0 1.0 6.0 12128.0 505.3 12700.0 473.0 41.0 1.0 6.0 12179.0 507.5 2 12650.0 478.0 37.0 1.0 6.0 12128.0 505.3 12500.0 474.0 42.0 1.0 6.0 11977.0 499.0 3 12650.0 478.0 38.0 1.0 6.5 12126.5 505.3 12570.0 473.0 40.0 1.0 6.5 12049.5 502.1 4 12650.0 479.0 38.0 1.5 6.0 12125.5 505.2 12580.0 474.0 39.0 1.5 6.0 12059.5 502.5 5 12610.0 477.0 37.0 0.5 5.5 12090.0 503.8 12590.0 475.0 38.0 0.5 5.5 12071.0 503.0 6 12620.0 476.0 36.0 1.0 5.5 12101.5 504.2 12590.0 482.0 38.0 1.0 5.5 12063.5 502.6 7 12630.0 477.0 39.0 1.0 6.0 12107.0 504.5 12580.0 463.0 37.0 1.0 6.0 12073.0 503.0 8 12670.0 476.0 38.0 1.0 5.5 12149.5 506.2 12640.0 473.0 39.0 1.0 5.5 12121.5 505.1 9 12650.0 476.0 38.0 1.0 5.5 12129.5 505.4 12610.0 474.0 36.0 1.0 5.5 12093.5 503.9 i10 12620.0 476.0 37.0 1.0 5.0 12101.0 504.2 12580.0 473.0 37.0 1.0 5.0 12064.0 502.7 i11 12640.0 476.0 38.0 1.0 5.5 12119.5 505.0 12610.0 473.0 37.0 1.0 5.5 12093.5 503.9 12 12640.0 477.0 37.0 1.0 5.5 12119.5 505.0 12620.0 473.0 36.0 1.0 5.5 12104.5 504.4 13 12620.0 476.0 38.0 1.0 5.0 12100.0 504.2 12590.0 473.0 37.0 1.0 5.0 12074.0 503.1 14 12670.0 479.0 38.0 1.0 5.5 12146.5 506.1 12640.0 474.0 37.0 1.0 5.5 12122.5 505.1 15 12670.0 478.0 37.0 1.0 6.0 12148.0 506.2 12620.0 475.0 37.0 1.0 6.0 12101.0 504.2 16 12640.0 481.0 36.0 1.0 5.5 12116.5 504.9 12610.0 475.0 39.0 1.0 5.5 12089.5 503.7 17 12580.0 479.0 33.0 1.5 6.5 12060.0 502.5 12560.0 474.0 44.0 1.5 6.5 12034.0 501.4 18 12590.0 482.0 34.0 1.0 6.5 12066.5 502.8 12580.0 476.0 45.0 1.0 6.5 12051.5 502.1 19 12630.0 479.0 34.0 1.0 6.0 12110.0 504.6 12610.0 474.0 43.0 1.0 6.0 12086.0 503.6 20 12640.0 479.0 32.0 1.0 5.5 12122.5 505.1 12620.0 476.0 43.0 1.0 5.5 12094.5 503.9 21 12660.0 480.0 31.0 1.0 6.0 12142.0 505.9 12630.0 477.0 42.0 1.0 6.0 12104.0 504.3 22 12660.0 479.0 33.0 1.0 5.5 12141.5 505.9 12760.0 476.0 42.0 1.0 5.5 12235.5 509.8 23 12680.0 477.0 32.0 0.5 5.5 12165.0 506.9 12550.0 476.0 39.0 0.5 5.5 12029.0 501.2 24 12640.0 480.0 33.0 1.0 6.0 12120.0 505.0 12610.0 476.0 43.0 1.0 6.0 12084.0 503.5 25 12670.0 479.0 34.0 1.5 5.5 12150.0 506.2 12650.0 476.0 40.0 1.5 5.5 12127.0 505.3 26 12700.0 476.0 36.0 0.5 5.0 12182.5 507.6 12660.0 473.0 46.0 0.5 5.0 12135.5 505.6 27 12690.0 476.0 33.0 1.0 5.0 12175.0 507.3 12620.0 473.0 26.0 1.0 5.0 12115.0 504.8 28 12710.0 479.0 37.0 0.5 5.5 12188.0 507.8 12670.0 476.0 36.0 0.5 5.5 12152.0 506.3 29 12700.0 480.0 38.0 1.0 6.0 12175.0 507.3 12660.0 486.0 38.0 1.0 6.0 12129.0 505.4 30 12690.0 480.0 37.0 1.5 6.5 12165.0 506.9 12650.0 467.0 38.0 1.5 6.5 12137.0 505.7 31 12690.0 480.0 37.0 0.5 5.5 12167.0 507.0 12630.0 475.0 37.0 0.5 5.5 12112.0 504.7 MnWT.TT.V MnMAPT.0 - rTT'T1T 1 MONTHLY TOTALS - UNIT 2 Gross Generation: 392,210.0 MWhr Gross Generation: 391,090.0 MWhr Total Station Service: 16,143.5 MWhr Total Station Service: 16,127.5 MWhr Net Generation: 376,066.5 MWhr Net Generation: 374,962.5 MWhr Average Daily Power: 505.5 MWe Average Daily Power: 504.0 MWe

PANP UNIT 1 CYCLE 27 JANUARY 2002 - BURNUP SYNOPSIS & REFUELING SCHEDULING DATA Gol-ý BURNUP DATA IN MWD/MTU THIS TOTAL PERIOD CYCLE 27 TOTAL CYCLE AVERAGE 1064. 8320. 28758. REGION AVERAGE 126B 384. 2896. 38882. 127A 327. 2426. 43808. 127B 746. 5719. 45661. 128A 1253. 9955. 31872. 128B 1359. 10845. 30771. 129A 1438. 11076. 11076. 129B 1268. 9891. 9891. CORE MWTHR 1128527. 8826308. 30506707. DAYS IN PERIOD/CYCLE 31 263 POWER FACTOR 99.9% 92.1% "* BASED ON NUMBER OF DAYS IN PERIOD OR CYCLE. PROJECTED EOL BURNUP 16042. 15439. "* BASED ON DAYS REMAINING UNTIL REFUELING DATE ASSUMING PERIOD OR CYCLE POWER FACTOR

                                           --------. REFUELING*SCHEDULE  DATA SCHEDULED REFUELING DATE    9/14/2002 DESIGN     TEN PPM      NOTE: DESIGN BURNUP IS THE END OF CYCLE BURNUP THAT WAS BURNUP FOR CYCLE   27 (MWD/MTU)                16285.      16200.            USED IN THE FINAL CORE DESIGN. TEN PPM BURNUP IS REMAINING EFFECTIVE FULL POWER DAYS            231.8       229.4             THE CORE AVERAGE BURNUP PROJECTED AT TEN PPM BORON FRACTION OF CYCLE LIFE EXPENDED                 51.1%       51.4%            BASED ON CURRENT BORON FOLLOW RESULTS.

ESTIMATED DATE FOR DESIGN AND TEN PPM BURNUPS ASSUMING VARIOUS POWER FACTORS POWER FACTOR 100.% 95.% 90.% 85.% 80.% 75.% 70.% 65.% TEN PPM BORON DATE 9/18/2002 9/:30/2002 10/13/2002 10/28/2002 11/14/2002 12/ 3/2002 12/25/2002 1/19/2003 DESIGN BURNUP DATE 9/20/2002 10/ 3/2002 10/16/2002 10/31/2002 11/17/2002 12/ 7/2002 12/29/2002 1/23/2003

PBNP UNIT 2 CYCLE 25 JANUARY 2002 BURNUP SYNOPSIS & REFUELING SCHEDULING DATA BURNUP DATA IN MWD/MTU THIS TOTAL PERIOD CYCLE 25 TOTAL CYCLE AVERAGE 1057. 13569. 32725. REGION AVERAGE 223D 341. 3976. 47735. 224A 303. 3541. 38846. 225A 703. 8760. 37802. 225B 440. 5295. 42963. 226A 1127. 14456. 42667. 226B 1277. 16736. 40315. 227A 1360. 17479. 17479. 227B 1187. 15355. 15355. CORE MWTHR 1128657. 14490181. 34 i946008. DAYS IN PERIOD/CYCLE 31 411 POWER FACTOR 100.0% 96.7%

  • BASED ON NUMBER OF DAYS IN PERIOD OR CYCLE.

PROJECTED EOL BURNUP 15992. 15913.

  • BASED ON DAYS REMAINING UNTIL REFUELING DATE ASSUMING PERIOD OR CYCLE POWER FACTOR REFUELINGSSCHEDULE DATA SCHEDULED REFUELING DATE 4/13/2002 DESIGN TEN PPM NOTE: DESIGN BURNUP IS THE END OF CYCLE BURNUP THAT WAS BURNUP FOR CYCLE 25 (MWD/MTU) 16660. 16660. USED IN THE FINAL CORE DESIGN. TEN PPM BURNUP IS REMAINING EFFECTIVE FULL POWER DAYS 90.6 90.6 THE CORE AVERAGE BURNUP PROJECTED AT TEN PPM BORON FRACTION OF CYCLE LIFE EXPENDED 81.4% 81.4% BASED ON CURRENT BORON FOLLOW RESULTS.

ESTIMATED DATE FOR DESIGN AND TEN PPM BURNUPS ASSUMING VARIOUS POWER FACTORS POWER FACTOR 100.% 95.% 90.% 85.% 80.% 75.% 70.% 65.% TEN PPM BORON DATE S/ 2/2002 5/ 7/2002 5 /12/2002 5/18/2002 5/25/2002 6/ 1/2002 6/10/2002 6/20/2002 DESIGN BURNUP DATE 5/ 2/2002 S/ 7/2002 5, /12/2002 5/18/2002 5/25/2002 6/ 1/2002 6/10/2002 6/20/2002

Page 1 of 1 Shift Operation Data January,2002 Unit 1 IUnit2 X0 x02 x04 Xo8X27 G0S Gen IGo Aux Z Day HrslGe] [--- 24 55750949.0217. Gen 74116.0181616.0160142.016329.01 120.015683.0 15849.0 W 24 564.0925. 425075366.0 82090.0 60184.0 6331 0 132.0 5683.0 5865.0 FY11I 24 1l8050I9730l225.I76623.o1182563. 160224.0 6333 01145 01 5683.0 58820o 4 24 19 24291.0 77881.0 83037.0 60263.0 6336.0 157.0 5683.0 5896.0 W 24 D651. 679024328.0179140.0 83512.0 60301.0 6337.0 168.0 5683.0 15909.0 W61241]61793.0 97185.0 24364.0 80399.0 83994.0 60339.0 6339.0 179.0 .5683.0 !5925.0 [Ull W-- 241630560 0197662. 0124403.01181657. 24-164323.01198138. 0124441.01182921. 0184457. 0184930. 0160376.0116341.011191.0115683 0160415.0116343.011202. 015683 0 11594o00 0 15953.0 Il-'il 165588.01198614.01124479.01184182.01185404.0[160451.016345.011213.0115683. 0 I5975.0 24 15963 0 10-]241166850.01199090.01124516.01185440.01185877.01160488.0116347.011223.0115683-0 11* 24 [68114.0l[99566.01124554.0l[86701.0[186350.01160525.01163490o12340o156830o 15988.0 12 24 69378.0]43.0 24591.0l87963.0[86823.0160561.0[6351.0[2450 5683.0 6001.0 13 124[]70640.011519.0 [24629.01189222.0[[87296.0ll60598.0[16353.0[[255.05683.0 16015.0[ 14 124[[71907.0 1998.0 124667.0[190486.01187770.0ll60635.0116355.0[[266.0115683.0 16030.0 1i5- 24 [73174,0111476.0 l24704.01191748.0[188245.0l[60672.01[6357.0[278.015683.0 l6044.0 [17 24 l75696.0[[2436.0 [24773.0 925. 9140 05506362.0[302.0 5686.0 [6077.0 18 4 769550 29180 24807.0 952. 89670.0 60800.0 6364031510 56860 60990 F19 24 78280 3397.0 24841.0 968. 90144.060843.0 63660 3270 56860 6118.0 20* 24 79482.0 3876.0 124873.0 984. 90620.0 [60886.0 6368.0 338.0 5686.0 [6133.0 22* 24 [82014.0 4350 497. 55.'957.0607006372.011361.0115686.0 [6160.0 F 121 F24 1183282.05 0 6 84 1 6373.0 372.0 5686.0 6172.0 24 j24 ][454.015. 250.03010922.0605. 6375.0 384.0 5686.0 6186.0 25- 4 88130 671. 2536.436.09301. 619.0678.0 395.0 56860 16197.0 262487830 677. 502. 5320 344. 1806379.0 405.0 56860 [6207.0 27- 4 832.[723i 210.0689.093470 1406381.0 415.0 5680 [62180 F24][E* 28 2489230 70.025420 16,094230

                                                                                    *I*

12006382.01426.0156860o 2*. [6232.01

         - I-24 0930             8120      258.0 9270 990.             628.      34.0 438.0 56860        [649.0   1 i*3 -I4 26.0 86.0                  227.      0920 937.             12606387.0i1451.015686.0      [16264,0 i I 3124142.343.02554. 1155.09581.06133.06388.0            462.0 56860   ~29 https://www.surfn-nuclear.com/wepcol/cgi-binldivers/generation/generation-meter.cgi?action=                        2/1/2002}}