NRC-93-0009, Forwards Fermi 2 Annual Operating Rept for 1992. Rept Satisfies Reporting Requirements of 10CFR20.407 & TS 6.9.1.5.a,b,c & D.Rept Also Include Section on Service Life of Main Steam Bypass Line,Per Commitment in Util

From kanterella
(Redirected from NRC-93-0009)
Jump to navigation Jump to search
Forwards Fermi 2 Annual Operating Rept for 1992. Rept Satisfies Reporting Requirements of 10CFR20.407 & TS 6.9.1.5.a,b,c & D.Rept Also Include Section on Service Life of Main Steam Bypass Line,Per Commitment in Util
ML20034F248
Person / Time
Site: Fermi 
Issue date: 02/26/1993
From: Gipson D
DETROIT EDISON CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20034F249 List:
References
CON-NRC-93-0009, CON-NRC-93-9 NUDOCS 9303020483
Download: ML20034F248 (1)


Text

E Douples R. Gipson i

$$$1tes JQ Deltoit rerma

(.m en D+e He*2v i:Cl.iSOn E W ""

nuclear February 26, 1993 NRC-93-0009 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555

Reference:

Fermi 2 NRC Docket No. 50-341 NRC License No. NPF-43 l

Subject:

1992 Annual Operating Report for Fermi 2 In accordance with Fermi 2 Technical Specification 6.9.1.4 and NRC Regulatory Guide 1.16, the Detroit Edison Company is submitting the Annual Operating Report for the Fermi 2 Nuclear Power Plant for the period of January 1, 1992 through December 31, 1992 (see Enclosure 1).

l The 1992 Annual Operating Report for Fermi 2 satisfies the reporting i

requi ements of 10CFR20.407, (Personnel Monitoring Report), Technical Spec'aication 6.9.1.5.a (Annual Exposure Report by Function), Technical Specification 6.9.1.5.b (Safety / Relief Valve Challenges), Technical Specification 6.9.1.5.c (Emergency Core Cooling System Outages), and Technical Specification 6.9.1.5.d (Specific Activity Analysis of the Primary Coolant). The 1992 Annual Operating Report also includes a section on service life of the main steam bypass line. This satisfies the commitment stated in Detroit Edison letter VP-86-0154 to the j

Nuclear Regulatory Commission dated November 7, 1986.

l If you have any questions or comments regarding this report, please i

contact Mr. Joseph Pendergast, Compliance Engineer, at (313) 586-1682.

Sincerely, Enclosure cc:

T. G. Colburn A. B. Davis W. J. Kropp j

M. P. Phillips 9303020483 930226

[

PDR ADOCK 05000341 R

PDR g//

)

l