Page 1 of 2 As of: November 16, 2011 Received: November 10, 2011 Status: PendingPost PUBLIC SUBMISSION Tracking No. 80f6a2a3 Comments Due: November 11, 2011 Submission Type: Web Docket: NRC-2011-0212 Issuance and Availability of Draft Regulatory Guide 7 6 Fie 5 "1/37 Comment On: NRC-2011-0212-0003 Monitoring the Effectiveness of Maintenance at Nuclear Power Plants Document: NRC-2011-0212-DRAFT-0002 Comment on FR Doc # 2011-27442 Submitter Information ,

Name: Todd Henderson Address: ""

341 White Pond Drive .-

Mail Stop A-WAC-B 1 Co Akron, OH, 44320 Organization: FirstEnergy Nuclear Operating Company General Comment Docket ID NRC-2011-0212, Draft Regulatory Guide DG-1278: Monitoring the Effectiveness of Maintenance at Nuclear Power Plants FENOC Comments on Proposed Revision 3 of Regulatory Guide 1.160 (DG- 1278), "Monitoring the Effectiveness of Maintenance at Nuclear Power Plants" I. In response to 76 FR 55137, September 6, 2011, and 76 FR 65753, October 24, 2011, FirstEnergy Nuclear Operating Company (FENOC) has reviewed the draft regulatory guide, and appreciates the opportunity to provide the following comment.

The introductory sentence of Section 1.7, titled "Scope of Initiators to be Considered for Shutdown Conditions",

states: "NUMARC 93-01 provides guidance to licensees on the scope of hazard groups to be considered for the 10 CFR 50.65(a)(4)assessment provision during power operating conditions." This statement appears unclear since the section discusses hazards to consider during shutdown conditions rather than power operating conditions.

2. Should you have any questions or comments, please contact:

John T. Gallagher

,E-P,0J:'A&,6 https://fms.e4rulemaking.net/fdms-web-agency/component/contentstreamer?objectld=0900006480f6a2a... 11/16/2011

Page 2 of 2 Technical Services Engineering FENOC-Beaver Valley Power Station (724) 682-7605 or Gregory H. Halnon FENOC Director, Fleet Regulatory Affairs Office (330) 436-1369 https://fdms.erulemaking.net/fdms-web-agency/component/contentstreamer?objectld=090000648Of6a2a... 11/16/2011