NL-09-155, Registration of Spent Fuel Cask Use

From kanterella
Jump to navigation Jump to search
Registration of Spent Fuel Cask Use
ML093440150
Person / Time
Site: Indian Point, Holtec  Entergy icon.png
Issue date: 11/25/2009
From: Robert Walpole
Entergy Nuclear Operations
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-09-155
Download: ML093440150 (2)


Text

Indian Point Energy Center 450 Broadway, GSB P.O. Box 249

.Enteigy Buchanan, N.Y. 10511-0249 Tel (914) 734-6710 Robert Walpole Manager Licensing NL-09-155 November 25, 2009 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Subject:

Indian Point Energy Center Registration of Unit 2 Spent Fuel Cask Use Indian Point, Unit 2 Docket Nos. 50-247 & 72-51 License No. DPR-26 Dear Sir or Madam; Entergy Nuclear Operations, Inc. (Entergy) operates the Indian Point Energy Center (IPEC)

Independent Spent Fuel Storage Installation (ISFSI) in accordance with the general license provisions of 10 CFR 72.210. The conditions of 10 CFR 72.212(b)(1)(ii) include the registration of a spent fuel cask within 30 days of using a cask for storage of spent nuclear fuel.

Accordingly, this letter hereby registers the use, on November 9, 2009, of the sixth (6) IPEC Unit 2 dry fuel storage cask. The cask was loaded to Amendment #2 of the Holtec CoC #1014 and the corresponding Holtec CFSAR Revision 4. This cask is the eleventh (11) IPEC dry fuel storage cask to be added to the IPEC ISFSI pad.

This letter also provides the following registration information associated with the eleventh Holtec HI-STORM 100 spent fuel cask system that was placed into storage on the IPEC ISFSI pad [Docket No. 72-51]. The fuel contained in this cask is from IPEC Unit 2 Nuclear Power Plant, Reactor License No. DPR-26, Docket No. 50-247.

[Sixth Unit 2 Spent Fuel Cask]

Eleventh IPEC Spent Fuel Cask System Date placed in use: Novemher 9. 2009 Date placed in use: November 9 2009 Licensee's Name: Entergy Operations, Inc.

Licensee's Address: Indian Point Energy Center 450 Broadway P.O. Box 249 Buchanan, NY 10511 Cask Model Number: HI-STORM 100 Cask Certificate Number: 1014 MPC Serial Number: 099 HI-STORM Overpack Serial Number: 0220 Number of Fuel Bundles: 32 fuel bundles AImI -)~5 6/

Indian Point Unit 2 Docket Nos. 50-247 & 72-51 License No. DPR-26 NL-09-155 Page 2 of 2 Total Cask Systems stored at the IPEC ISFSI pad [Docket No. 72-511:

Eleven (11) HI-STORM 100 Cask Systems Entergy is making no new commitments in this letter. Should you have any questions regarding this matter, please contact Mr. Timothy J. Salentino, Superintendent Dry Fuels Storage, at Indian Point Energy Center at (914) 734-6421.

Sincerely you

'ýobert:WA/I olele-Manager, Li ensing Indian Point Energy Center cc: NRC Resident Inspector's Office Mr. John Boska, Senior Project Manager, NRC NRR DORL Mr. Theodore Smith, Project Manager, NRC FSME DWMEP Mr. Samuel Collins, Regional Administrator, NRC Region 1 Mr. Robert Callender, Vice President of Programs, NYSERDA Mr. Paul Eddy, New York State Dept. of Public Service