Crane Clean Energy Center - NRC Independent Spent Fuel Storage Security Inspection Report 07200077/2025401
ML25318B193
Person / Time
Site: Crane 
Issue date: 11/20/2025
From: Brice Bickett
Decommissioning, ISFSI, and Reactor Health Physics Branch
To: Rhoades D
Constellation Energy Generation
References
IR 2025401
Download: ML25318B193 (1)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION REGION I 475 ALLENDALE ROAD, SUITE 102 KING OF PRUSSIA, PA 19406-1415 November 20, 2025 Mr. David P. Rhoades Senior Vice President Constellation Energy Generation, LLC President and Chief Nuclear Officer Constellation Nuclear Warrensville, IL 60555

SUBJECT:

CRANE CLEAN ENERGY CENTER - NRC INDEPENDENT SPENT FUEL STORAGE SECURITY INSPECTION REPORT NO. 07200077/2025401

Dear Mr. Rhoades:

On September 25, 2025, the U.S. Nuclear Regulatory Commission (NRC) completed a security inspection at your Crane Clean Energy Center, Independent Spent Fuel Storage Installation (ISFSI),

in Middletown, Pennsylvania. The inspection covered your physical security plan and compliance with the October 16, 2002, Interim Compensatory Measures for Dry Independent Spent Fuel Storage Installations Order. This inspection was conducted using NRC Inspection Procedure 81311, Physical Security Requirements for Independent Spent Fuel Storage Installations.

The results of the inspection were discussed with Mr. Clint Six, Site Vice President, and other members of your staff during a final exit meeting held on September 25, 2025.

The inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations and with the conditions of your license.

Within these areas, the inspection consisted of an examination of selected procedures and representative records, observations of activities, and interviews with personnel.

Based on the results of this inspection, no violations were identified.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public Inspections, Exemptions, Requests for Withholding, of the NRCs Rules of Practice, a copy of this cover letter and enclosure will be available electronically for public inspection in the NRCs Public Document Room or from the Publicly Available Records (PARS) component of the NRCs Agencywide Document Access Management System (ADAMS), accessible from the NRC Website at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

D. Rhoades 2

Sincerely, Brice Bickett, Chief Security, Emergency Preparedness and Incident Response Branch Division of Radiological Safety and Security Docket No.

07200077 License No.

DPR-50

Enclosure:

Inspection Report No. 07200077/2025401 cc w/encl:

Distribution via ListServ D. Kenny, Manager, Nuclear Security D. Shearer, Director, Bureau of Radiation Protection, PA Department of Environmental Protection BRICE BICKETT Digitally signed by BRICE BICKETT Date: 2025.11.20 12:04:24 -05'00'

D.Rhoades 3

SUBJECT:

CRANE CLEAN ENERGY CENTER - NRC INDEPENDENT SPENT FUEL STORAGE SECURITY INSPECTION REPORT NO. 07200077/2025401 DATED: NOVEMBER 20, 2025 DISTRIBUTION w/ encl: (via E-mail)

CRegan, DRSS MFerdas, DRSS TEck, DRSS ADimitriadis, DRSS DTift, SLO SBurnell, PAO BBickett, DRSS EEve, DRSS NFloyd, DORS DGarner, NSIR JRey, NSIR EWharton, NSIR JClark, NSIR JWorsolio, RII MZiolkowski, RIII JRollins, RIV R1ORAMAIL Resource DOCUMENT NAME: https://usnrc.sharepoint.com/teams/RIDRSPSBSEC/Shared Documents/Inspection Reports/2025 IR Final/Crane Clean Energy Center/CCEC ISFSI IR 2025401 Non OUO - FINAL.docx SUNSI Review TEck ADAMS Accession Number ML25318B193 SUNSI Review Non-Sensitive Sensitive Publicly Available Non-Publicly Available OFFICE RI/DRSS RI/DRSS NAME TEck BBickett DATE 11/18/25 11/20/2025 OFFICAL RECORD COPY

Enclosure U.S. NUCLEAR REGULATORY COMMISSION REGION I Inspection Report Docket No.

07200077 License No.

DPR-50 Report No.

07200077/2025401 Enterprise Identifier:

I-2025-401-0025 Licensee:

Constellation Energy Group (CEG)

Facility:

Crane Clean Energy Center, Independent Spent Fuel Storage Installation (ISFSI)

Location:

Middletown, PA Inspection Dates:

September 23, 2025, to September 25, 2025 Inspectors:

T. Eck, Senior Physical Security Inspector Approved By:

Brice A. Bickett, Branch Chief Security, Emergency Preparedness and Incident Response Branch Division of Radiological Safety and Security

2

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an independent spent fuel storage installation security inspection at Crane Clean Energy Center Independent Spent Fuel Storage Installation, in accordance with the NRC Inspection Procedure 81311, Physical Security Requirements for Independent Spent Fuel Storage Installations.

List of Violations No violations were identified.

Additional Tracking Items None

3 INSPECTION SCOPE Unless otherwise noted, independent spent fuel storage installation security inspections are conducted in accordance with the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection. Currently approved inspection procedures with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html.

The inspection was declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter 2690, Inspection Program for Dry Storage of Spent Reactor Fuel and Reactor Related Greater-Than-Class C Waste at Independent Spent Fuel Storage Installations and for 10 CFR Part 71 Transportation Packings. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

Inspection Procedure 81311 - Physical Security Requirements for Independent Spent Fuel Storage Installations This inspection was conducted in accordance with Sections 02.01 through 02.08, General License Requirements and Guidance for Co-Located / AFR ISFSI, of Inspection Procedure 81311, Physical Security Requirements for Independent Spent Fuel Storage Installations. All inspection requirements outlined in these sections of the IP were fully satisfied.

INSPECTION RESULTS No violations were identified.

EXIT MEETING The inspector verified no proprietary information was retained or documented in this report.

On September 25, 2025, the inspector presented the inspection results to Clint Six, Site Vice President, and other members of the licensees staff.

4 DOCUMENTS REVIEWED Inspection Procedure Type Designation Description or Title Revision or Date 81311 Corrective Action Documents Reviewed 04849503, 04843438, 04844210, 04843304, 04843376, 04842733, 04839098, 04837961, 04779282, 04755297, 04691358, 04560518, 04543588 81311 Miscellaneous TMI ISFSI Safeguards Event Reports 2023, 2024, 2025 81311 TMI Nuclear Station ISFSI Security Plan Revision 001 81311 NOSA-TMI-23-01 Security Programs Audit Report March 15, 2023 81311 NOSA-TMI-25-02 Fitness for Duty Access Authorization Program Audit Report March 13, 2025 81311 Calculations C-1101-114-012 Design Basis Threat Calculation Revision 0 81311 Procedures SY-TM-701 Contingency Response Guidance Revision 0 81311 SY-TM-702 Security System Component Degradation Compensatory Measures Revision 0 81311 SY-TM-703 Physical Protection Measures for the ISFSI Revision 0 81311 SY-TM-716 Conducting Patrols Revision 0 81311 SY-TM-720 Control of Security Access Control Devices Revision 0 81311 SY-TM-722 Testing Security Equipment Revision 0 81311 SY-TM-722-101 Performance of Perimeter Intrusion Detection /

Camera System Testing Revision 0 81311 SY-TM-750 Nuclear Security Training Program Revision 0 81311 SY-TM-750-103 Firearms Maintenance, Testing and Accountability Revision 0 81311 SY-TM-1530 Testing Security Surveillance Systems Revision 3 81311 SY-TM-1704 OCA / Protected Area Searches Revision 0 81311 SY-TM-1707 Security Operational Duties Revision 0