U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 618 (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.

a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9405 0

71-9405 USA/9405/B(U)-96 1

OF 3

2.

PREAMBLE

a. This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
b. This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3.

THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION a.

ISSUED TO (Name and Address)

b. TITLE AND IDENTIFICATION OF REPORT OR APPLICATION QSA Global, Inc.

40 North Avenue Burlington, MA 01803 Safety Analysis Report for the Model No. 1100 Transport Packages, Revision No. 0, dated October 2024.

4. CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.

5.

(a) Packaging (1)

Model No. 1100 (2)

Description The Model No. 1100 package is designed for use as an industrial radiography exposure device and as a transport package for Type B quantities of radioactive material in special form. The 1100 has a maximum capacity of 150 Curies of Iridium-192 or 150 Curies of Selenium-75.

The 1100 package, without the jacket, is cylindrical in shape with a diameter of 5 inches (127 mm) and a length of 13 inches (330 mm). With the jacket, the shape of the package is an extruded triangle that is 8.5 inches (226 mm) tall, 6.5 inches (168 mm) wide, and 13 inches (330 mm) long.

The weight of the 1100 is 44 pounds (20 kg) without the jacket, and 48 pounds (22 kg) with the jacket.

The major components of the package consist of a welded stainless steel cylindrical body, a depleted uranium shield, a rear plate with locking assembly, a front plate assembly, a containment system (special form source), and optional jacket.

U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 618 (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.

a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9405 0

71-9405 USA/9405/B(U)-96 2

OF 3

5(a)(2)

Description (continued)

The depleted uranium shield is suspended inside the welded body between the endplate by brackets that are welded to the inside of each endplate. A copper spacer fills the gap between the shield and the bracket. An S-shaped titanium source tube is cast into the center of the shield to provide a cavity for the source wire assembly and shipping plug assembly to travel through during use.

The rear plate with locking assembly is attached to the welded body with four tamperproof screws through rivnuts assembled into the endplate. The front plate assembly is attached to the welded body with three tamperproof screws through rivnuts assembled into the endplate. The rear plate assembly consists of a source wire locking mechanism fastened to the rear plate. The front plate assembly consists of a shielded port mechanism contained within the front plate.

An optional polyurethane jacket covers the package cylinder, provides a handle and a stable base, and is attached to the shell cylinder by posts and screws located outside the shield cavity area.

(3)

Drawings The packaging is constructed in accordance with the QSA Global, Inc., drawing R1100 Descriptive Drawing, Rev. A, sheets 1-6.

(b) Contents (1)

Type and form of material Iridium-192 as a sealed source which meets the requirements of special form radioactive material.

Selenium-75 as a sealed source which meets the requirements of special form radioactive material.

(2)

Maximum quantity of material per package Ir-192: 150 Curies (5.55 TBq) (output).

Se-75: 150 Curies (5.55 TBq).

Output curies for Ir-192 are determined by measuring the source output at 1 meter and expressing its activity in curies derived from the following: 0.48 R/(hr-Ci)

(Ref: American National Standards Institute N432-1980, Radiological Safety for the Design and Construction of Apparatus for Gamma Radiography).

U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 618 (8-2000) 10 CFR 71 CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.

a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9405 0

71-9405 USA/9405/B(U)-96 3

OF 3

5.(b)

Contents (continued)

(3) Maximum weight: 18 grams.

(4) Maximum decay heat: 2.1 Watts.

6.

In addition to the requirements of Subpart G of 10 CFR Part 71:

(a)

The package shall be prepared for shipment and operated in accordance with the Operating Procedures in Chapter 7.0 of the application; and, (b)

The package must meet the Acceptance Tests and Maintenance Program of Chapter 8.0 of the application.

7.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.17.

8.

Expiration date: August 31, 2030.

REFERENCES QSA Global, Inc., application Model 1100 Type B(U) Transport Package, Revision No. 0, dated October 2024, as supplemented on February 11, 2025, and June 2, 2025.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Yoira Diaz-Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Date: September 8, 2025 Signed by Diaz-Sanabria, Yoira on 09/08/25