ML25216A289

From kanterella
Jump to navigation Jump to search
Attachment 5: Proposed HI-STORM Umax CoC Amendment 5- Changed Pages
ML25216A289
Person / Time
Site: HI-STORM 100
Issue date: 08/04/2025
From:
Holtec
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML25216A283 List:
References
5021081
Download: ML25216A289 (1)


Text

Approved Contents 2.0 Certificate of Compliance No.1040 Amendment No. 52 Appendix B 2-22 Table 2.3-5 HI-STORM UMAX Version B2 MPC-37 PERMISSIBLE HEAT LOADS MPC Type Fuel Type (See Table 2.1-4 for length data)

Fuel Assembly Array and Class Heat Load limit per Storage Cell (Note 1)

Permissible Aggregate Heat Load (Note 2),

kW MPC-37 Standard Fuel 16x16 A Figure 2.3-17 11.6510.87 Note 1: See Figure 2.3-17 for more details about per cell heat load.

Note 2: The aggregate heat load is defined as a sum of all stored fuel assemblies.

Table 2.3-6 HI-STORM UMAX Version B2 MPC-37 Type 1 PERMISSIBLE HEAT LOADS MPC Type Fuel Type (See Table 2.1-4 for length data)

Fuel A ssembly Array and Class Heat Load limit per Storage Cell (Note 1)

Permissible Aggregate Heat Load (Note 2),

kW MPC-37 Type 1 Standard Fuel 16x16 A Figure 2.3-18 9.50 Note 1: See Figure 2.3-18 for more details about per cell heat load.

Note 2: The aggregate heat load is defined as a sum of all stored fuel assemblies.

to Holtec Letter 5021081

Approved Contents 2.0 Certificate of Compliance No.1040 Amendment No. 52 Appendix B 2-39 1

0.33005 2

0.24023 3

0.3050.33 0

4 0.315291 5

0.36539 6

0.39567 7

0.3390.36 5

8 0.2910.31 5

9 0.3050.33 0

10 0.3390.36 5

11 0.26544 12 0.2440.26 5

13 0.2440.26 5

14 0.3390.36 5

15 0.3050.33 0

16 0.2230.24 0

17 0.3670.39 5

18 0.2440.26 5

19 0.2440.17 5

20 0.2440.26 5

21 0.3670.39 5

22 0.2230.24 0

23 0.3050.33 0

24 0.3390.36 5

25 0.2440.26 5

26 0.2440.26 5

27 0.2440.26 5

28 0.3390.36 5

29 0.3050.33 0

30 0.2910.31 5

31 0.3390.36 5

32 0.3670.39 5

33 0.3390.36 5

34 0.2910.31 5

35 0.3050.33 0

36 0.2230.24 0

37 0.3050.33 0

Figure 2.3-17 HI-STORM UMAX B2 MPC-37 Permissible Heat Load for Standard Fuel 16x16A Legend Cell ID Heat Load, kW to Holtec Letter 5021081