ML25134A300

From kanterella
Jump to navigation Jump to search

U.S. Nuclear Regulatory Commission Staff Review Re Reed College 2023 Financial Test for Self-Guarantee for Decommissioning Funding
ML25134A300
Person / Time
Site: Reed College
Issue date: 05/21/2025
From: Miller A
NRC/NRR/DANU/UNPL
To: Newhouse J
Reed College
Stamler B
References
EPID L-2024-NFO-0012
Download: ML25134A300 (1)


Text

Mr. Jerry Newhouse, Director Reed Research Reactor Reed College 3203 Southeast Woodstock Boulevard Portland, OR 97202-8199

SUBJECT:

U.S. NUCLEAR REGULATORY COMMISSION STAFF REVIEW RE: REED COLLEGE 2023 FINANCIAL TEST FOR SELF-GUARANTEE FOR DECOMMISSIONING FUNDING (EPID NO. L-2024-NFO-0012)

Dear Mr. Newhouse:

Pursuant to paragraph (e)(1)(iii)(C) of Title 10 of the Code of Federal Regulations (10 CFR)

Section 50.75, Reporting and recordkeeping for decommissioning planning, and Appendix E to 10 CFR Part 30, Criteria Relating to Use of Financial Tests and Self-Guarantee for Providing Reasonable Assurance of Funds for Decommissioning by Nonprofit Colleges, Universities, and Hospitals, Reed College submitted a self-guarantee letter to the U.S. Nuclear Regulatory Commission (NRC) to demonstrate financial assurance for decommissioning dated September 18, 2024 (Agencywide Documents Access and Management System Accession No. ML24282A783).

The NRC staff has completed its review and finds that the Reed College self-guarantee agreement meets the financial test criteria for a non-profit college that issues bonds, is sufficient for providing financial assurance, and meets the applicable requirements of Appendix E to 10 CFR Part 30 and 10 CFR 50.75. Enclosed is a summary of the NRC staffs financial review of the Reed College self-guarantee.

May 20, 2025

J. Newhouse If you have any questions regarding this matter, please contact Bradley Stamler at 301-415-1147, or via email at Bradley.Stamler@nrc.gov.

Sincerely, Andrew Miller, Project Manager Non-Power Production and Utilization Facility Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Docket No. 50-288 License No. R-112

Enclosure:

As stated cc: GovDelivery Subscribers Signed by Miller, Andrew on 05/20/25

ML25134A300 NRR-106 OFFICE NRR/DANU/UNPL/PM NRR/DANU/UNPL/LA NMSS/FAB/BC NRR/DANU/UNPL/BC NAME BStamler NParker FMiller JRady DATE 5/15/2025 5/15/2025 5/19/2025 5/20/2025 OFFICE NRR/DANU/UNPL/PM NAME AMiller DATE 5/20/2025

Enclosure SAFETY EVALUATION BY THE OFFICE OF NUCLEAR MATERIAL SAFETY AND SAFEGUARDS ANNUAL FINANCIAL TEST FOR A SELF-GUARANTEE REED COLLEGE (DOCKET NO. 50-288)

1.0 INTRODUCTION

By letter dated September 30, 2024 (Agencywide Documents Access and Management System Accession No. ML24282A783), Reed College provided documentation in support of its self-guarantee for demonstrating decommissioning funding assurance, in accordance with NUREG-1757, Financial Assurance, Recordkeeping, and Timeliness, Volume 3 and Title 10 of the Code of Federal Regulations (10 CFR), Appendix E to 10 CFR Part 30, Criteria Relating to Use of Financial Tests and Self Guarantees for Providing Reasonable Assurance of Funds for Decommissioning by Nonprofit Colleges, Universities and Hospitals. The purpose of this financial test is to demonstrate that Reed College can continue maintaining $6,851,190 (in 2024 dollars) in coverage for decommissioning funding assurance for the research reactor and related facilities located at Reed College in Portland, Oregon 2.0 ANALYSIS The requirements of paragraph (e)(1)(iii)(C) to 10 CFR Section 50.75, Reporting and recordkeeping for decommissioning planning, state, in part, that [f]or non-profit entities, such as colleges, a guarantee of funds by the applicant or licensee may be used if the guarantee and test are as contained in Appendix E to 10 CFR part 30. As a non-profit college, Reed College qualifies to use the self-guarantee as reflected in Appendix E to 10 CFR Part 30. The U.S.

Nuclear Regulatory Commission (NRC) staff evaluated Reed Colleges submittal to determine whether its proposed guarantee and test criteria meet those as contained in Appendix E to 10 CFR Part 30. The NRC staff reviewed Reed Colleges submittal pursuant to the elements specified in Appendix E to 10 CFR Part 30, including the financial test requirements, self-guarantee requirements, and additional requirements, as contained in Section II, Financial Test, and Section III, Self-Guarantee, of Appendix E to 10 CFR Part 30, and guidance contained in NUREG-1757.

3.0 SYNTHESIS Based on its review, the NRC staff finds that the licensee provided complete documentation, including a letter from Reed Colleges Vice President and Treasurer containing the self-guarantee financial test; an independent auditors report confirming the Vice President and Treasures letter and reconciling amounts with the licensees financial statements; and the licensees audited financial statements for the most recent fiscal year. In addition, the NRC staff finds that the licensee does not have a parent company holding a majority control of its voting stock and that the amount of the self-guarantee exceeds the required coverage level. In consideration of the exceptions noted above, the NRC staff finds that the self-guarantee agreement meets the financial test criteria for a non-profit university that issues bonds, is sufficient for providing financial assurance, conforms to the guidance in NUREG-1757, and meets the requirements of 10 CFR 50.75 and Appendix E of 10 CFR Part 30.

Regarding financial test requirements, Appendix E to 10 CFR Part 30 requires a bond issuing licensee to have a current [credit] rating for its most recent uninsured, uncollateralized, and unencumbered bond issuance of Aaa, Aa, or A (including adjustments of 1, 2, or 3) as issued by Moodys. As stated in the Reed College Self-Guarantee Agreement provided with its October 22, 2022, submittal, the Standard and Poors (S&P) Global bond rating for Reed Colleges most recent uninsured, uncollateralized, and unencumbered bond was rated AA-

/Stable. The S&P Global bond rating of AA-/Stable, meets the test criteria of Aaa, Aa, or A as provided in Appendix E to 10 CFR Part 30.

The NRC staff notes that the NRC is currently addressing, through rulemaking, changes to its surety requirements used by licensees. These changes are responsive to the 2010, Dodd-Frank Wall Street Reform and Consumer Protection Act legislation (Dodd-Frank), which, among other things, seeks to have agencies remove reference to or requirements for reliance on credit ratings, and impacts NRCs financial tests for colleges, universities, and hospitals who use self-guarantees for providing reasonable assurance of funds for decommissioning. As a result, the NRC staff would disallow reliance on use of credit ratings as a financial test for providing reasonable assurance of funds for decommissioning. In the case of a university or college currently relying on bond ratings to qualify for use of a self-guarantee, such as Reed College, licensees would instead rely on the financial test in Appendix E to 10 CFR Part 30, II.A.(2). This financial test requires that the applicant meet unrestricted endowment criteria consisting of assets located in the United States of at least $50 million, or at least 30 times the total current decommissioning cost estimate, whichever is greater.

As provided in the Reed College Self-Guarantee Agreement submittal, the licensees financial statements reflect total endowment funds of $6,841,307 (June 30, 2023), and a cost to decommission the reactor of $6,851,190 (2024 dollars). Accordingly, the licensees unrestricted endowment is greater than 30 times the total current decommissioning cost estimate and therefore meets the endowment criteria in Appendix E to 10 CFR Part 30, II.A.(2).

Based on the NRC staffs analyses, the licensee meets the financial test for use of a self-guarantee using either credit ratings or unrestricted endowment criteria. In consideration of the above, the NRC staff finds that Reed College has fulfilled the requirements for a university seeking to provide decommissioning funding assurance using a self-guarantee.

4.0 CONCLUSION

The NRC staff has reviewed the decommissioning financial assurance mechanism for the research reactor at Reed College. Based on its review, the NRC staff finds that the licensee provided complete documentation, including a letter from Reed Colleges Vice President/

Treasurer containing the self-guarantee financial test; an independent auditors report confirming the Vice President/Treasurer letter and reconciling amounts with the licensees financial statements; and the licensees audited financial statements for the most recent fiscal year. In addition, the NRC staff finds that the self-guarantee agreement meets the financial test criteria for a non-profit college that issues bonds, is sufficient for providing financial assurance

($6,851,190 in 2024 dollars) for decommissioning of the Reed College facility and conforms to NRC guidance. Therefore, the NRC staff concludes that Reed College meets the requirements of Appendix E to 10 CFR Part 30 and 10 CFR 50.75.

Principal Contributor: L. Pope, NMSS