ML25121A134

From kanterella
Jump to navigation Jump to search
Revision to Refueling Outage 26 Inservice Inspection Owner’S Activity Report
ML25121A134
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 05/01/2025
From: Joseph Turner
Wolf Creek
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
000928
Download: ML25121A134 (1)


Text

P.O. Box 411 l Burlington, KS 66839 l 620-364-8831 Joshua K. Turner Acting Director Regulatory Affairs May 1, 2025 000928 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Reference:

1) Letter 000592, from D. T. Hamman to U.S. NRC, dated September 4, 2024, Inservice Inspection Program Fourth Interval, Third Period, Refueling Outage 26 Owners Activity Report, NRC ADAMS ML24248A249.

Subject:

Docket No. 50-482: Revision to Refueling Outage 26 Inservice Inspection Owners Activity Report Commissioners and Staff:

Based on an operating experience (OE) review of Owners Activity Reports (OAR-1), Wolf Creek Nuclear Operating Corporation (WCNOC) is submitting a revision to the 10 CFR 50.55a OAR-1 from Refueling Outage 26 (RF26) listed in Reference 1.

WCNOC has traditionally not included mandatory ASME Code Cases in OAR-1 submittals based on the reasoning they are required code cases under 10 CFR 50.55a and thereby understood to be included in the program. However, based on a recent OE review of reports from other stations, the site determined these mandantory code cases should be listed in the report.

As a result, the RF26 OAR-1 report has been revised to include the mandatory code cases N-722-1, N-729-6, and N-770-5 in the line labeled Code Cases used for inspection and evaluation.

No other changes have been made to the report.

The revision has been reviewed by the Authorized Nuclear Inspector and is included in the Enclosure. The OE review leading to the revision is documented in the stations corrective action program as condition report 10038145.

This letter contains no commitments. If you have any questions concerning this matter, please contact me at (620) 364-8831 x8261, or Dustin Hamman at (620) 364-4204.

Sincerely, Joshua K. Turner

000928 Page 2 of 2

Enclosure:

WCNOC ISI Form OAR-1, Report Number WCRE-30, I4/P3-RF26, Rev 1 cc:

A. N. Agrawal (NRC), w/e S. S. Lee (NRC), w/e J. D. Monninger (NRC), w/e Senior Resident Inspector (NRC), w/e WCNOC Licensing Correspondence RA 25-000928, w/e

Enclosure to 000928 Wolf Creek Nuclear Operating Corporation Inservice Inspection Program Owners Activity Report (Form OAR-1, Report Number WCRE-30, I4/P3-RF26, Rev 1)

(3 pages)