Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID: 5021080 Page 1 of 2 January 31, 2025 Ms. Daneira Melendez-Colon, Project Manager Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 72-1040 Certificate of Compliance (CoC) No. 1040RA

Subject:

HI-STORM UMAX Amendment 5 Responses to Requests for Additional Information

Reference:

[1] NRC letter, Follow-Up to Request for Additional Information responses for review of the Holtec Model No. HI-STORM UMAX Storage System, Amendment 5

- Cost Activity Code/Enterprise Project Identification Numbers 001028/L-2023-LLA-0176 from D. Melendez-Colon (NRC) to A. Elzahri (Holtec), dated December 9, 2024 Docket No. 72-1040 Certificate of Compliance No. 1040 Amendment No. 5 Model No. HI-STORM UMAX

Dear Ms. Melendez-Colon:

Holtec is pleased to submit the Follow-Up responses to the HI-STORM UMAX Amendment 5 Requests for Additional Information (RAI) asked by staff in Ref [1].

This submittal includes a response to the RAIs as Attachment 1. As some of these responses contain proprietary information, a nonproprietary version is included as Attachment 2. The full set of impacted HI-STORM UMAX FSAR changed pages are included as Attachment 3. contains a proprietary structural calculation package. Since Attachments 1 and 4 contain proprietary information, Attachment 5 contains an affidavit requesting that these documents be withheld from public disclosure.

Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Document ID: 5021080 Page 2 of 2 If you have any questions or require any additional information, please contact me at 856-797-0900 ext. 3469.

Sincerely, Ali Elzahri Licensing Project Engineer Holtec International cc:(via email)

Kim Manzione (Holtec)

Yoira Diaz Sanabria (USNRC)

Attachments: : HI-STORM UMAX Amendment 5 RAI responses (proprietary) : HI-STORM UMAX Amendment 5 RAI responses (non-proprietary) : Proposed HI-STORM UMAX FSAR Amendment 5-Changed Pages (non-proprietary) : HI-2125228 Revision 18 Structural Calculation package for the HI-STORM UMAX System (proprietary) : Affidavit Pursuant to 10CFR2.390 (non-proprietary)