David P. Rhoades Senior Vice President Constellation Energy Generation, LLC President and Chief Nuclear Officer (CNO)
Constellation Nuclear 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
LASALLE COUNTY STATION - EMERGENCY PREPAREDNESS BIENNIAL EXERCISE INSPECTION REPORT 05000373/2024501 AND 05000374/2024501
Dear David Rhoades:
On November 22, 2024, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at LaSalle County Station and discussed the results of this inspection with J. Van Fleet, Site Vice President, and other members of your staff. The results of this inspection are documented in the enclosed report.
No findings or violations of more than minor significance were identified during this inspection.
December 26, 2024
D. Rhoades 2
This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely, Michael E. Ziolkowski, Chief Security, Emergency Preparedness, and Incident Response Branch Division of Radiological Safety and Security Docket Nos. 05000373 and 05000374 License Nos. NPF-11 and NPF-18
Enclosure:
As stated cc: R. Vanderhyden, Emergency Preparedness Manager cc w/ encl: Distribution via LISTSERV Signed by Ziolkowski, Michael on 12/26/24
D. Rhoades 3
Letter to D. Rhoades from M. Ziolkowski dated December 26, 2024.
SUBJECT:
LASALLE COUNTY STATION - EMERGENCY PREPAREDNESS BIENNIAL EXERCISE INSPECTION REPORT 05000373/2024501 AND 05000374/2024501 DISTRIBUTION:
Robert Ruiz RidsNrrDorlLpl3 RidsNrrPMLaSalle Resource RidsNrrDroIrib Resource Jack Giessner Mohammed Shuaibi Diana Betancourt-Roldan Allan Barker Harral Logaras David Curtis Jared Heck R3-DORS Jefferson Clark SOSBInspRptDistro@usnrc.onmicrosoft.com ADAMS ACCESSION NUMBER: ML24358A194
SUNSI Review
Non-Sensitive
Sensitive
Publicly Available
Non-Publicly Available OFFICE RIII/DRSS RIII/DRSS NAME JKutlesa MZiolkowski DATE 12/23/2024 12/26/2024 OFFICAL RECORD COPY
Enclosure U.S. NUCLEAR REGULATORY COMMISSION Inspection Report Docket Numbers:
05000373 and 05000374 License Numbers:
NPF-11 and NPF-18 Report Numbers:
05000373/2024501 and 05000374/2024501 Enterprise Identifier:
I-2024-501-0013 Licensee:
Constellation Nuclear Facility:
LaSalle County Station Location:
Marseilles, IL Inspection Dates:
November 18, 2024 to November 22, 2024 Inspectors:
B. Jose, Senior Reactor Inspector J. Kutlesa, Sr Emergency Preparedness Inspector K. Maloney, Sr Physical Security Inspector T. Ospino, Resident Inspector Approved By:
Michael E. Ziolkowski, Chief Security, Emergency Preparedness, and Incident Response Branch Division of Radiological Safety and Security
2
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an emergency preparedness biennial exercise inspection at LaSalle County Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.
List of Findings and Violations No findings or violations of more than minor significance were identified.
Additional Tracking Items None.
3 INSPECTION SCOPES Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html.
Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
REACTOR SAFETY 71114.01 - Exercise Evaluation Inspection Review (IP Section 02.01-02.11) (1 Sample)
(1)
The inspectors observed the biennial exercise and evaluated emergency plan performance on November 19, 2024. The exercise scenario simulated an event at the Lasalle Nuclear Generating Station that initiated with the declaration and notification of an Alert in response to an earthquake that caused significant damage to the standby liquid control tank and associated suction piping. The scenario conditions simulated the escalation of the significance of the event, requiring the declaration of a General Emergency which was communicated to the required state and local government agencies.
71114.08 - Exercise Evaluation - Scenario Review Inspection Review (IP Section 02.01 - 02.04) (1 Sample)
(1)
The inspectors reviewed and evaluated the proposed scenario for biennial emergency plan exercise on October 16, 2024.
4 OTHER ACTIVITIES - BASELINE 71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:
EP01: Drill/Exercise Performance (DEP) Sample (IP Section 02.12) (1 Sample)
(1)
July 1, 2023 through September 30, 2024.
EP02: Emergency Response Organization (ERO) Drill Participation (IP Section 02.13)
(1 Sample)
(1)
July 1, 2023 through September 30, 2024.
EP03: Alert And Notification System (ANS) Reliability Sample (IP Section 02.14) (1 Sample)
(1)
July 1, 2023 through September 30, 2024.
INSPECTION RESULTS No findings were identified.
EXIT MEETINGS AND DEBRIEFS The inspectors verified no proprietary information was retained or documented in this report.
On November 22, 2024, the inspectors presented the emergency preparedness biennial exercise inspection results to J. Van Fleet, Site Vice President, and other members of the licensee staff.
5 DOCUMENTS REVIEWED Inspection Procedure Type Designation Description or Title Revision or Date 71114.01 Procedures EP-AA-1005 Radiological Emergency Plan Annex for Lasalle Station 41 71114.08 Miscellaneous E240917t164800_RS-24-089 LaSalle County Station 2024 NRC Graded Exercise Manual 09/17/2024 LS-AA-2110 Monthly Data Elements for NRC ROP Indicator -
Emergency Response Organization (ERO) Drill Participation 07/01/2023 -
09/30/2024 LS-AA-2120 Monthly Data Elements for NRC ROP Indicator -
Drill/Exercise Performance 07/01/2023 -
09/30/2024 71151 Miscellaneous LS-AA-2130 Monthly Data Elements for NRC ROP Indicator - Alert and Notification System (ANS) Reliability 07/01/2023 -
09/30/2024