OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION December 23, 2024 James W. McIntyre Quality Assurance Director Sargent & Lundy, LLC 55 East Monroe Chicago, Illinois 60603-5780
SUBJECT:
DRAFT SAFETY EVALUATION FOR SARGENT & LUNDYS PROPOSED REVISION 27 TO SL-TR-1 NUCLEAR QUALITY ASSURANCE PROGRAM (EPID L-2024-TOP-0011)
Dear James McIntyre:
By letter dated April 1, 2024 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML24094A163), Sargent & Lundy, LLC (S&L), submitted proposed Revision 27 to SL-TR-1, Nuclear Quality Assurance Program, Topical Report (TR) for the U.S. Nuclear Regulatory Commission (NRC) staffs review and approval. Based on its review of the information submitted in the TR, the NRC staff finds the TR acceptable for referencing subject to the limitations specified in the TR, and in the NRC safety evaluation (SE).
A copy of the draft SE has been placed in the box.com folder. You have been given access to the folder. The draft SE is being provided for a proprietary information review.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), we have determined that the draft SE may contain proprietary information. If you believe that any information in the draft SE is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390. Please use bold brackets and yellow highlight to identify any ((proprietary information)).
Your response must be via a letter from an authorized individual. Please provide your response within 20 working days. The final SE will be issued after making any necessary changes.
Note that at this stage of the process, the NRC staff has completed its review of the submitted information and will not entertain technical arguments. The staffs conclusions and conditions will not change unless new information is provided on the docket that was not available during our review. If S&L would like to discuss the draft SE in detail, we can do that in a noticed meeting.
NOTICE: Enclosure to this letter contains Proprietary Information. Upon separation from Enclosure, this letter is DECONTROLLED.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION The draft SE has been placed in ADAMS. The draft SE was made an Official Agency Record and declared as nonpublic because it may contain proprietary information. This email will be placed into ADAMS, made an Official Agency Record, and declared public.
If you have any questions, please contact Jeffery Smith via phone at 301-415-4116 or via email at Jeffery.Smith@nrc.gov.
Sincerely,
/RA/
Gerond George, Chief Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 99900507
Enclosure:
Draft SE (Proprietary)
ML24352A273 (Package)
ML24352A255 (Letter)
ML24352A282 (Draft SE Proprietary)
OFFICE NRR/DORL/LLPB/PM* NRR/DORL/LLPB/LA NRR/DRO/IQVB/BC OGC NLO NAME JSmith DHarrison KKavanagh SGellen DATE 12/17/2024 12/19/2024 12/20/2024 12/11/2024 OFFICE NRR/DORL/LLPB/BC NRR/DORL/LLPB/PM NAME GGeorge JSmith DATE 12/23/2024 12/23/2024