1 CLOSED MEETING ANNOUNCEMENT
Title:
Table-Top Demonstration on Selection of a Seismic Scenario for an EPZ Boundary Determination Date(s) and Time(s): December 17, 2024, 01:00 PM to 04:30 PM ET Location:
NRC HQ-OWFN-01F24 Category:
This is a Closed meeting. Contains trade secrets and commercial or financial information (proprietary information).
Purpose:
The U.S. Nuclear Regulatory Commission (NRC) staff will meet with the Nuclear Energy Institute (NEI), TerraPower, LLC., and Southwest Research Institute (SwRI) on NEIs White paper on selection of a seismic scenario for an Emergency Planning Zone (EPZ) boundary determination (ML24187A096). At this meeting, NEI and TerraPower will discuss design features and detailed design information on the development, testing, licensing, and deployment of the Natrium reactor and its associated fuel, structures, systems, and components and will conduct a tabletop demonstration of the NEI white paper methodology.
Contact:
Belkys Sosa 301-415-3357 belkys.sosa@nrc.gov
Participants:
NRC Office of Nuclear Reactor Regulation Office of Nuclear Regulatory Research SwRI TerraPower NEI The NRC provides reasonable accommodations to individuals with disabilities where appropriate. If you need a reasonable accommodation to participate in a meeting or need a meeting notice or the transcript or other information from a meeting in another format (e.g. braille, large print), please contact Anne Silk, NRC Reasonable Accommodations Coordinator, at Anne.Silk@nrc.gov or call directly at 301-287-0745.
Determinations on requests for reasonable accommodation will be made on a case-by-case basis. Ten (10) days advance notice is requested to try to ensure availability; however, every effort will be made to address a request for reasonable accommodations with less notice.
2 CLOSED MEETING AGENDA Table-Top Demonstration on Selection of a Seismic Scenario for an EPZ Boundary Determination December 17, 2024 1:00 p.m. - 4:30 p.m.
Meeting called by US NRC - Division of Advanced Reactors and Non-Power Production and Utilization Facilities (DANU) Advanced Reactor Policy Branch to discuss proprietary information that could not be provided by NEI during the public stakeholder meeting on December 12, 2024.
1:00 p.m. - 1:05 p.m.
Introductions
All 1:05 p.m. - 1:10 p.m.
Overview & Agenda Topics/Scheduling B. Sosa 1:10 p.m. - 1:45 p.m.
Introduction NEI Brief recap of responses to NRC comments Additional discussion/responses on the following topics:
GMRS Fragility analysis Define the scenario Consequence analysis Cliff-edge sensitivity 1:45 p.m. - 3:45 p.m.
Tabletop demonstration NEI/TerraPower Examples that show how the C10% criterion is applied at a cutset level, how a plant damage state is determined, and how the doses were calculated. The examples should also include evaluation of cliff-edge effects. The examples should include sensitivity studies considering various design options under the non-LLWR RIPB based seismic design.
3:45 p.m. - 4:25 p.m.
Final questions, next steps, and wrap-up 4:30 p.m.
Closing Remarks 10 min Break @ 2:30pm
3 ADAMS Accession Number: ML24341A209 Distribution:
B. Sosa, NRR M. Wentzel, NRR A. Munis, NRR J. Segala, NRR M. Stutzke, NRR O. Dukes, NRR W. Wang, RES T. Weaver, RES J. Pires, RES L. Bauer, RES OFFICIAL RECORD COPY
4 NOTIFICATIONS john.stamatakos@swri.org kristin.ulmer@swri.org ravindramalathi@cox.net kra@nei.org
5 Commission's Policy Statement on "Enhancing Public Participation in NRC Meetings" 86 FR 14964, March 19, 2021 ADAMS No. ML21050A046 https://www.nrc.gov/reading-rm/doc-collections/commission/policy/index.html