December 17, 2024 MEMORANDUM TO:

Mahmoud Jardaneh, Chief New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation FROM:

River J. Rohrman, Project Manager /RA/

New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation

SUBJECT:

U.S. NUCLEAR REGULATORY COMMISSION

SUMMARY

OF THE OCTOBER 2, 2024, OBSERVATION PUBLIC MEETING ON THE STATUS OF NUSCALES US460 STANDARD DESIGN APPROVAL APPLICATION The U.S. Nuclear Regulatory Commission (NRC) held an observation public meeting on October 2, 2024, to discuss topics related to NuScale Power, LLCs (NuScale) US460 Standard Design Approval Application (SDAA) available in the NRCs Agencywide Documents Access and Management Systems (ADAMS) Package Accession No. ML23306A033. This meeting was part of a periodic NRC and NuScale management engagement to discuss the status of the application, technical topics of interest, project processes and workflows. The meeting consisted of open and closed portions.

During the open portion of the meeting, the NRC staff gave an overview of the status of the NuScale application review. The staff discussed the progress of the ongoing audit for Phase A of the safety review. The staff noted completion of the following SDAA review phases:

Phase A (Advanced Safety Evaluation Report (ASER) without open items) - Chapters 2, 3 (except 3.7, 3.8, and 3.9.2), 7, 8, 9, 10, 11, 12, 13, 14, 17 (except 17.4), 18 and 19 (19.4, 19.5).

Phase B (ASER review (technical editing), Legal and Management concurrence) -

Chapters 2, 7, 9, 10, 11, 12, 13, 17 (except 17.4), 18, and 19 (19.4, 19.5).

Phase C (ACRS Review of ASER) - Chapters 2, 7, 9, 10, 11, 12, 13, 17 (except 17.4),

and 18.

CONTACT:

River J. Rohrman, NRR/DNRL Getachew Tesfaye, NRR/DNRL River.Rohrman@nrc.gov 301-415-8013

M. Jardaneh The staff also discussed the status of the High Impact Technical Issues (HITIs). The staff noted that the main issues associated with the following HITI have been resolved and removed from the list:

HITI-6: Secondary side controller design for DWO events The staff also presented the statuses of the eight Licensing Topical Reports (LTRs) submitted in the pre-application phase and the four LTRs submitted with the SDAA. The review of all eight of the LTRs submitted in the pre-application phase are completed. The four LTRs that were submitted at same time as the SDAA are being reviewed concurrently with the SDAAs safety review. The presentation material for the open portion of the meeting can be found in ML24269A077 (nonproprietary).

The closed portion of the meeting was held to discuss proprietary items.

The public meeting notice dated October 2nd, 2024, was posted on the NRC public website, and can be found under ML24270A060. The enclosure to this summary provides a list of the meeting participants.

Docket Nos. 99902078 and 05200050

Enclosure:

List of Attendees cc w/encl.: NuScale Power, LLC Listserv

Pkg: ML24337A180 Memo: ML24337A189 Slides: ML24269A077 Slides: ML24269A078 (Proprietary)

Meeting Notice: ML24270A060

  • via email NRR-106 OFFICE NRR/DNRL/NRLB: PM NRR/DNRL/NLIB: LA NRR/DNRL/NRLB: PM NAME RRohrman SGreen GTesfaye DATE 11/15/24 12/02/24 11/29/24 OFFICE NRR/DNRL/NRLB: BC NAME MJardaneh DATE 12/17/24

Enclosure U.S. NUCLEAR REGULATORY COMMISSION

SUMMARY

OF THE OCTOBER 2, 2024, OBSERVATION PUBLIC MEETING ON THE STATUS OF NUSCALES US460 STANDARD DESIGN APPROVAL APPLICATION LIST OF ATTENDEES October 2, 2024 Name Organization Andrea Kock U.S. Nuclear Regulatory Commission (NRC)

Greg Bowman NRC Mahmoud Jardaneh NRC Michele Sampson NRC Getachew Tesfaye NRC Stewart Bailey NRC Tania Martinez Navedo NRC Samuel Lee NRC Meena Khanna NRC Theresa Clark NRC Ricky Vivanco NRC Tommy Hayden NRC Greg Cranston NRC Stacy Joseph NRC Dennis Galvin NRC Alina Schiller NRC River Rohrman NRC Prosanta Chowdhury NRC Rebecca Patton NRC Carrie Fosaaen NuScale Mark Shaver NuScale Tom Griffith NuScale Robert Gamble NuScale J. J. Arthur NuScale Tim Polich RoPower Spencer Toohill Breakthrough Institute