From:
Zozula, Camille T.
Cc:
Mackereth, Nathaniel J; Yagozinski, Joshua; Gerond George; Scott Krepel; Jeremy Dean; John Lehning; Patrick Raynaud (He/Him); Brandon Wise; Jack Vande Polder (He/Him)
Subject:
U. S. Nuclear Regulatory Commission Request for Additional Information Westinghouse Topical Report WCAP-18850-P/NP, "Adaptation of the FULL SPECTRUM' LOCA (FSLOCA') Evaluation Methodology to Perform Analysis of Cladding Rupture for High Burnup Fuel" Date:
Wednesday, November 27, 2024 1:33:00 PM Camille Zozula Manager, Infrastructure & Facilities Licensing Westinghouse Electric Company 1000 Westinghouse Drive, Building 1 Cranberry Township PA 16066
Dear Camille Zozula,
By \
letter dated February 29, 2024 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML24060A160), Westinghouse Electric Company (Westinghouse) submitted Topical Report (TR) WCAP-18850-P/NP, Revision 0, Adaptation of the FULL SPECTRUM' LOCA (FSLOCA') Evaluation Methodology to Perform Analysis of Cladding Rupture for High Burnup Fuel (Proprietary/Non-proprietary) for the U. S. Nuclear Regulatory Commission (NRC) review and approval. The NRC staff has reviewed the TR WCAP-18850-P/NP, Revision 0, conducted the regulatory audit on October 22-23, 2024, and determined that additional information is required to complete the review.
I have placed an electronic version of theproprietary version of the NRC RAIquestionsforWestinghouse TR WCAP-18850-P/NP, Revision 0,in the box.com folder and have given Nathaniel Mackereth, Westinghouse, access to it. The non-proprietary version of the RAIs can be accessed in ADAMS. This email serves as a formal transmittal of the RAIquestions. When responding to the RAIquestions, please provide proprietary and non-proprietary versions of the responses.
Nathaniel Mackereth, Westinghouse, indicated via email dated November 26, 2024, that the responses to the NRCRAIs will be submitted to the NRC within 60 days from the receipt of the RAIs. In order to support theNRCreview schedule, please provide RAI responses within that timeframe.
This email will also go in ADAMS and will be declared public.
If you have any questions, please feel free to contact me at 301-415-3151 or by email at Ekaterina.Lenning@nrc.gov.
Sincerely, Ekaterina Lenning Licensing Projects Branch Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission
Docket No.99902038
ML24332A025 (Pkg)
ML24332A026 (NON-PROPRIETARY WCAP-18850 RAI 10444-R1-FINAL-REDACTED)
ML24332A027 (PROPRIETARY WCAP-18850 RAI 10444-R1-FINAL)
ML24332A124 (E-mail)