ML24313A014
| ML24313A014 | |
| Person / Time | |
|---|---|
| Issue date: | 02/12/2025 |
| From: | NRC/NRR/DNRL/NLIB |
| To: | NRC/NRR/DNRL/NLIB |
| References | |
| Download: ML24313A014 (3) | |
Text
U.S. NUCLEAR REGULATORY COMMISSION
SUMMARY
OF THE MAY 23, 2024, OBSERVATION PUBLIC MEETING TO DISCUSS PUBLIC COMMENT RESPONSES AND PROPOSED CHANGES TO SUBSEQUENT LICENSE RENEWAL GUIDANCE Meeting Agenda Time Session Comment No.
Topic Speakers 0900-0915 Introduction/Opening Remarks NRC 0915-0945 Comments Overview NRC 0945-1000 BREAK 1000-1130 General 20 Reduction of NRC SLR Application Review Time NRC/Industry Representatives (IRs)
General 21,32-000 Reduction of NRC SLR Application Review Time NRC/IRs Mech. Session 1 3, 11, 12, 17 Eliminate One-Time Inspections: Multiple AMPs NRC/IRs Mech. Session 1 6, 7, 8, 9, 10, 15, Eliminate Prescriptive Corrective Actions/Inspections: Multiple AMPs NRC/IRs Mech. Session 1 9 XI.M27: Eliminate Prescriptive Corrective Actions/Inspections NRC/IRs Mech. Session 1 32-013,32-016, Eliminate Opportunistic Inspections: Multiple AMPs NRC/IRs Mech. Session 1 32-020 XI.M21A, Corrosion Inspection Guidance NRC/IRs Mech. Session 1 32-024 Testing and Inspection of Sprinkler System Piping NRC/IRs Mech. Session 1 32-025 XI.M27: Eliminate Prescriptive Corrective Actions/Inspections NRC/IRs Mech. Session 1 32-029,32-030 XI.M27: Fire Pump Suction Strainer and Intake Screen Inspections NRC/IRs Mech. Session 1 32-031 XI.M27: Flow Testing of Automatic Standpipe System NRC/IRs Mech. Session 1 32-032 XI.M27: Alternative Methods of Verifying Fire Water System Intended Functions NRC/IRs Mech. Session 1 32-040 XI.M32: Eliminate Prescriptive Corrective Actions/Inspections NRC/IRs Mech. Session 1 32-115 XI.M33: Substantial Changes To Guidance Due to Single OE NRC/IRs Mech. Session 1 32-041 XI.M33: Eliminate Opportunistic Inspections NRC/IRs Mech. Session 1 32-042 XI.M33: Hardness Testing to Detect Selective Leaching NRC/IRs Mech. Session 1 13 XI.M33 Eliminate Prescriptive Corrective Actions/Inspections NRC/IRs
Time Session Comment No.
Topic Speakers 1130-1230 LUNCH 1230-1330 Mech. Session 2 29-024 XI.M33: Additional Non-destructive Examination Techniques NRC/IRs Mech. Session 2 32-099 XI.M36 & XI.M38 Similar VT-1/VT-3 Inspections for non-ASME Code Components NRC/IRs Mech. Session 2 29-027 XI.M41: Sample Size Internal Volumetric Exams NRC/IRs Mech. Session 2 32-055 XI.M41: Coating Recommendation, Buried Cementitious Piping NRC/IRs Mech. Session 2 32-067 XI.M42: Eliminate Prescriptive Corrective Actions/Inspections NRC/IRs Mech. Session 2 25,32-068 XI.M43: Eliminate New AMP NRC/IRs Mech. Session 2 32-116 XI.M43: No Adequate Technical Basis for New AMP NRC/IRs Mech. Session 2 24 XI.M43:Eliminate Prescriptive Corrective Actions/Inspections NRC/IRs Mech. Session 2 29-006 XI.M43: Loss of Material, Exposure to Temp./Moisture in AMRs NRC/IRs Mech. Session 2 29-007 XI.M43: Delete Moisture From AMR Aging Mechanism NRC/IRs 1330-1430 Mech. Session 3 29-031 XI.M43: Loss of Material Due to Radiation, Temp. and Moisture NRC/IRs Mech. Session 3 32-113 XI.M43: CFRP Delamination, Disbonding, Flow Blockage NRC/IRs Mech. Session 3 29-030 XI.M43: AMP for Buried/Aboveground Non-safety HDPE Piping NRC/IRs Mech. Session 3 29-032 XI.M43: Accumulation of Particulate Fouling NRC/IRs Mech. Session 3 29-033 XI.M43: Accumulation of Particulate Fouling NRC/IRs Mech. Session 3 32-001 XI.M43: Remove Cracking as Applicable Aging Effect for CFRP NRC/IRs Mech. Session 3 32-078 XI.M43: Tests and Inspections for HDPE and CFRP NRC/IRs Mech. Session 3 32-089 XI.M43: Eliminate Prescriptive Corrective Actions/Inspections NRC/IRs Mech. Session 3 32-101 Long-term Loss of Material Due to General Corrosion NRC/IRs Mech. Session 3 32-102 Further Evaluation on Recurring Internal Corrosion NRC/IRs
Time Session Comment No.
Topic Speakers 1430-1445 BREAK 1445-1545 Structural/Electric al 19 XI.S6: Structures Monitoring, Change Insp.
Frequency NRC/IRs Structural/Electric al 31-002 Clarification on GALL Vol. 1, Item II.A1.CP-32 (leaching of calcium hydroxide and carbonation)
NRC/IRs Structural/Electric al 31-003 Clarification on GALL Vol. 1, Item II.A1.CP-32 (carbonation aging mechanism )
NRC/IRs Structural/Electric al 31-006 Clarification of GALL Vol. 1, Item III.A4.TP-305 (containment internal structures)
NRC/IRs Structural/Electric al 31-007 Clarification of GALL Vol. 1, Item III.A4.T-36 (Air - indoor uncontrolled env.)
NRC/IRs Structural/Electric al 32-018 XI.M18, XI.S1, XI.S3, XI.S6, Cracking of High-Strength Bolting NRC/IRs Structural/Electric al 29-010,32-095, Potentially, unknown Env. Exposure of Inaccessible Cables NRC/IRs Structural/Electric al 32-093 XI.E3A, XI.E3B, and XI.E3C Remove Requirement for Level Control Alarm at Central Location or Control Room NRC/IRs 1545-1600 Closing Remarks
/ Public Comments and Questions NRC/Public