SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved Natrium reactor is a TerraPower & GE Hitachi technology ACRS Full Committee Meeting November 2024 Plume Exposure Pathway Emergency Planning Zone Sizing Methodology TP-LIC-PRSNT-0031
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 2
- Overview of NAT-3056, TerraPower, LLC (TerraPower) Natrium Topical Report:
Plume Exposure Pathway Emergency Planning Zone Sizing Methodology
- Guidance Used
- Methodology
- Conclusion Table of Contents
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 3
- Regulatory Guide 1.242, Performance-Based Emergency Preparedness for Small Modular Reactors, Non Light-Water Reactors, and Non-Power Production or Utilization Facilities was utilized in developing the overall methodology.
- Supporting information from NUREG-0396, Planning Basis for the Development of State and Local Government Radiological Emergency Response Plans in Support of Light Water Nuclear Power Plants was used to assist in the development of the evaluation criteria.
NAT-3056 Guidance Used
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 4
- Assesses all modes and all hazards
- Incorporates site specific meteorological data
- Assesses radiological consequences
- Identifies prompt protective measures
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 5
- Includes DBAs
- Includes events with a 95th percentile release frequency greater than 1E-7
- Includes events for cliff-edge consideration if they have a release frequency greater than 1E-8 NAT-3056 Non-seismic Event Selection
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 6
- Mean: 8E-9, 95th percentile: 2E-8 screened out of EPZ evaluation NAT-3056 Non-Seismic Event Selection Example
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 7
- Developed a bounding seismic event for the CPA
- Will generate a list of seismic EPZ events using a limiting PGA as threshold NAT-3056 Seismic Event Selection
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 8
- Limiting PGA is LOWER of the two:
- Ensures that range of seismic hazard within credible range of ground motions
- Acknowledges limitations of the SPRA
- Acknowledges uncertainties in the emergency response infrastructure NAT-3056 Development of Limiting PGA
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 9
- Criterion A: Projected doses from the DBAs would not exceed 1 rem mean 4-day TEDE and 5 rem 95th percentile 4-day TEDE.
- Criterion B: Projected doses from most radiological release sequences would not exceed 1 rem mean 4-day TEDE and 5 rem 95th percentile 4-day TEDE.
- Criterion C: Immediate life-threatening doses from the worst-case radiological release sequences would not exceed 24-hour, 200 rem red marrow acute effective dose.
NAT-3056 Criteria for PEP EPZ Sizing
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 10 Supported by guidance
- NUREG-0396 - Planning Basis for the Development of State and Local Government Radiological Emergency Response Plans in Support of Light Water Nuclear Power Plants
- NUREG-7009 and NUREG-7161 - MACCS best practices and technical basis in the SOARCA
- NUREG-4214 - Health Effects Models for Nuclear Power Plant Accident Consequence Analysis Identified as most limiting and confirmed by sensitivity analysis Available for quantification within MACCS NAT-3056 Red Bone Marrow Use
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 11
- EPZ size is set based on smallest distance criteria are met.
- If the criteria are NOT met at the desired EPZ size, determination is made if design changes or refinements can be made to reduce EPZ size. Otherwise EPZ is expanded to meet the criteria.
NAT-3056 Conclusion
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 12
SUBJECT TO DOE COOPERATIVE AGREEMENT NO. DE-NE0009054 Copyright © 2024 TerraPower, LLC. All Rights Reserved 13 CPA - Construction Permit Application DBA - Design Basis Accident EPZ - Emergency Planning Zone GMRS - Ground Motion Response Spectra MACCS - MELCOR Accident Consequence Code System PEP - Plume Exposure Pathway PGA - Peak Ground Acceleration PRA - Probabilistic Risk Assessment SOARCA - State-of-the-Art Reactor Consequence Analysis SPRA - Seismic Probabilistic Risk Assessment TEDE - Total Effective Dose Equivalent Acronym List