ML24306A042
| ML24306A042 | |
| Person / Time | |
|---|---|
| Site: | 07103043 |
| Issue date: | 10/23/2024 |
| From: | Shaw D Orano TN Americas |
| To: | Boyle R Office of Nuclear Material Safety and Safeguards, US Dept of Transportation, Pipeline & Hazardous Materials Safety Admin |
| Shared Package | |
| ML24306A041 | List: |
| References | |
| E-63985 | |
| Download: ML24306A042 (1) | |
Text
Orano TN 7160 Riverwood Drive Suite 200 Columbia, MD 21046 USA Tel: 410-910-6900 Fax: 434-260-8480 Enclosures transmitted herein contain SUNSI. When separated from enclosures, this transmittal document is decontrolled.
October 23, 2024 E-63985 U.S. Department of Transportation Attn: Mr. Richard W. Boyle Pipeline & Hazardous Materials Safety Administration Radioactive Materials Branch 1200 New Jersey Avenue, S.E.
East Building, PHH-20 Washington, DC 20590
Subject:
Response to Request for Supplemental Information for Materials Package Design Certificate USA/0535/AF-96, Revalidation of Japanese Competent Authority Certificate J/105/AF 96
Reference:
[1] TN Americas letter E-62910 dated December 8, 2023,
Subject:
Materials Package Design Certificate USA/0535/AF-96, Revalidation of Japanese Competent Authority Certificate J/105/AF 96
[2] DOT Letter from Richard W. Boyle (DOT) to DFM Director (NRC) dated April 2, 2024, (ADAMS Accession Number: ML24248A221)
[3] NRC Letter from Tilda Liu (NRC) to Richard W. Boyle (DOT), dated October 9, 2024, Request for Revalidation of Japanese Certificate of Approval No. J/105/AF, dated September 13, 2023 - Request for Supplemental Information, Docket No. 71-3043, (EPID No.
L-2024-DOT-0000 and ADAMS Accession No: ML24263A139)
Dear Mr. Boyle:
TN Americas LLC, on behalf of behalf of Mitsubishi Nuclear Fuel Co., Ltd. (MNF),
applied in accordance with §173.473 for revalidation of the Japanese Competent Authority Certification [1]. In response to a U.S. Department of Transportation (DOT) request for recommendation [2], the U.S. Nuclear Regulatory Commission (NRC) requested supplemental information to start their review of the application [3]. provides MNF responses to the supplemental information requested. is a statement of proprietary information pursuant to 49 CFR 7.14, 49 CFR 105.30, and 10 CFR 2.390 for the supplemental information provided in.
E-63985 U.S. Department of Transportation Page 2 of 2 Lastly, we have included a non-proprietary version of the Model MFC-1 Package Safety Analysis Report (Enclosure 3), a non-proprietary version of the MNF Fundamental Policy of Quality Management (Enclosure 4), and a revision comparison table of the MNF Fundamental Policy of Quality Management (Enclosure 5).
Should you have any questions or require additional information to support review of this application, please contact Doug Yates by telephone at 434-832-3101, or by e-mail at douglas.yates@orano.group.
Sincerely, Don Shaw Licensing Manager TN Americas LLC cc:
Laurence Labbe, Senior Project Manager, TN Americas LLC Toshihiro Matsuoka, MNF Norihiko Kaneko, MNF Doug Yates, TN Americas LLC
Enclosures:
- 1. Response to Request for Supplemental Information for Revalidation of MFC-1 (Proprietary)
- 2. Statement of Proprietary Information
- 3. Model MFC-1 Package Safety Analysis Report (Non-Proprietary)
- 4. MNF Fundamental Policy of Quality Management (Non-Proprietary)
- 5. Revision Comparison Table of the MNF Fundamental Policy of Quality Management (Non-Proprietary)
SHAW Donis Digitally signed by SHAW Donis Date: 2024.10.23 09:13:50
-04'00'