ML24303A405
| ML24303A405 | |
| Person / Time | |
|---|---|
| Site: | 07003103 |
| Issue date: | 10/29/2024 |
| From: | Freels J URENCO USA |
| To: | Christine Pineda, Rowley J NRC/NMSS/DREFS/EPMB2 |
| References | |
| Download: ML24303A405 (1) | |
Text
From:
Freels, Jim To:
Jonathan Rowley; Christine Pineda (She/Her)
Subject:
[External_Sender] RE: [EXT] FW: request for clarification Date:
Tuesday, October 29, 2024 2:24:54 PM
Dear all,
The revised table below corrects the errors in the previously submitted table. The revised values are highlighted.
The table was checked for all years entries for verification.
Please let me know if you have any questions or need additional information.
Kind regards, Jim
UUSA Occupational TEDE 2015 - 2022 Revised: 29 October 2024
Year
Number of workers monitored
Collective TEDE (mrem / mSv)
Average TEDE (mrem / mSv)
Highest Individual TEDE Received (mrem / mSv) 2015 75 4774 / 47.74 63.7 / 0.637 336 / 3.36 2016 79 4802 / 48.02 60.8 / 0.608 292 / 2.92 2017 65 3862 / 38.62 59.4 / 0.594 258 / 2.58 2018 65 4648 / 46.48 71.5 / 0.715 337 / 3.37 2019 105 5841 / 58.41 55.6 / 0.556 345 / 3.45 2020 59 4943 / 49.43 83.8 / 0.838 310 / 3.10 2021 52 5082 / 50.82 97.7 / 0.977 375 / 3.75 2022 61 4245 / 42.45 69.6 / 0.696 399 / 3.99 Average TEDE to workers: 70.3 mrem (0.703 mSv)
Jim Freels Licensing Consultant
UUSA l PO Box 1789 l Eunice l New Mexico l 88231 l USA Tel:+1 575.394.6018 l Mob: +1 865.724.7636l Email:jim.freels@urenco.com l Web:www.uusa.urenco.com.
From: Jonathan Rowley <Jonathan.Rowley@nrc.gov>
Sent: Tuesday, October 29, 2024 11:25 AM
To: Freels, Jim <Jim.Freels@urenco.com>
Subject:
[EXT] FW: request for clarification Importance: High
External Email
Jim
Please reply to this email with the answer to the highlighted question (see below).
- Thanks, Jonathan
From: Christine Pineda (She/Her) <Christine.Pineda@nrc.gov>
Sent: Tuesday, October 29, 2024 12:19 PM To: Jonathan Rowley <Jonathan.Rowley@nrc.gov>
Subject:
request for clarification Importance: High
Hello Jonathan,
I have another request for clarification. Similar to the previous request, if UUSA could respond via email I can add that to ADAMS and reference it in the EA. In the environmental section of the application, they have a table titled UUSA Occupational TEDE 2015 - 2022. In that table, the 2019 and 2017 collective TEDE numbers dont seem to add up correctly, or else the average TEDEs are incorrect. Could UUSA please explain this or provide a corrected table, also verifying that all other years are correctly totaled? If we could have this information in the next day, that would be very helpful.
Thank you, Christine
This email transmission is confidential Louisiana Energy Services, LLC and intended solely for the person or organization to which it is addressed. If you are not the intended recipient, you must not copy, distribute or disseminate the information or take any action in reliance of it. Any views expressed in this message are those of the individual sender, except where the sender specifically states them to be the views of any organization or employer. If you have received this message in error, do not open any attachment but please notify the sender (above) and delete this message from your system. Please rely on your own virus check, as no responsibility is taken by the sender for any damage arising out of any bug or virus.