OFFICIAL USE ONLY - PROPRIETARY INFORMATION EXPORT CONTROLLED INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION EXPORT CONTROLLED INFORMATION October 24, 2024 Mr. John Bolin Senior Staff Engineer, Nuclear Technologies and Materials Division General Atomics - Electromagnetic Systems 16530 Via Esprillo San Diego, CA 92127
SUBJECT:
U.S. NUCLEAR REGULATORY COMMISSION STAFF FEEDBACK REGARDING GENERAL ATOMICS ELECTROMAGNETIC SYSTEMS WHITE PAPER: FAST MODULAR REACTOR SOURCE TERM METHODOLOGY (EPID L-2023-LRO-0086)
Dear Mr. Bolin:
By letter dated November 9, 2023 (Agencywide Documents Access and Management System (ADAMS) Accession No.: ML23317A091) General Atomics Electromagnetic Systems (GA-EMS) submitted a white paper (WP) titled, Fast Modular Reactor Source Term Methodology, (ML23317A093) for the U.S. Nuclear Regulatory Commission (NRC) staffs review. The WP describes the methodology used for radiation source term calculation and analysis results of GA-EMSs helium-cooled fast modular rector design.
The enclosure to this letter provides the NRC staffs feedback on the November 9, 2023, WP for GA-EMS to consider as part of any future submittal that may address this topic.
OFFICIAL USE ONLY - PROPRIETARY INFORMATION EXPORT CONTROLLED INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION EXPORT CONTROLLED INFORMATION If you have questions regarding this matter, please contact me via email at Samuel.CuadradoDeJesus@nrc.gov.
Sincerely, Samuel Cuadrado, Project Manager Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Project No.: 99902098
Enclosure:
As stated The enclosure to this letter contains proprietary and export-controlled information. When separated from the enclosure, this document is DECONTROLLED.
SAMUEL CUADRADO DE JESUS Digitally signed by SAMUEL CUADRADO DE JESUS Date: 2024.10.24 21:27:13 -04'00'
Package: ML24277A183 Letter: ML24277A278
Enclosure:
ML24277A277 NRR-106 OFFICE NRR/DANU/UAL1:PM NRR/DANU/UAL1:LA NRR/DANU/UTB2:BC NAME SCuadradoDeJesus DGreene ASiwy DATE 9/16/2024 9/19/2024 9/26/2024 OFFICE NRR/DANU/UAL1:BC NAME JBorromeo DATE 10/24/2024