PREDECISIONAL ENFORCEMENT CONFERENCE
SUMMARY
Licensee:
BWXT Nuclear Operations Group, Inc.
Facility:
BWXT Nuclear Operations Group, Inc. - Lynchburg License No.:
SNM-42 Docket No.:
07000027 EA Case No.:
EA-24-039 On August 28, 2024, representatives of BWXT met with NRC personnel in the NRC Region 2 office located in Atlanta, GA, to discuss an apparent violation in NRC Inspection Report No.
07000027/2024-006; (NRCs Agencywide Documents Access and Management System (ADAMS) Accession No. ML24151A460). The conference was held at the request of the licensee and was conducted in-person with some participants and members of the public attending virtually via Microsoft Teams.
The licensee presented a summary of the causes for the apparent violation and their corrective actions. A copy of the presentation is publicly available in ADAMS Accession No. ML24248A229.
The attendance list is attached to this summary (Enclosure 1).
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the NRCs Agencywide Documents Access and Management System (ADAMS),
accessible from the NRC Web site at https://www.nrc.gov/reading-rm/adams.html
Enclosure:
- 1. Attendance List
2 LIST OF MEETING ATTENDEES NAME ORGANIZATION M. Doyle NRC RII N. Pitoniak NRC RII E. Michel NRC RII L. Dudes NRC RII O. Lopez Santiago NRC RII J. Rivera Ortiz NRC RII D. Gasperson NRC RII S. Price NRC RII C. Riveria Diaz NRC HQ M. Kowal NRC RII N. Peterka NRC RII J. Grice NRC RII C. Ubben NRC RII N. Woodward NRC RII M. Day NRC RII M. Checkle NRC RII M. Greenleaf NRC RII K. Sullivan NRC RII M. Magyar NRC RII R. Penmetsa NRC RII D. Parent NRC RII K. Morgan Butler NRC HQ J. Downs NRC HQ J. Downs NRC HQ J. Zimmerman NRC HQ R. Carpenter NRC HQ S. Lav NRC HQ B. Karmiol NRC HQ H. Rodriguez NRC HQ J. Chai NRC HQ J. Bittner BWXT NOG R. Freudenberger BWXT NOG D. Ashworth BWXT NOG D. William Gerding BWXT NOG A. Coleman Member of public G. Core Member of public W. Doane Member of public K. R. Geber Member of public J. Rosenleaf Member of public Y. Inokuchi Member of public 8 additional unidentified attendees Members of public