ML24241A159
| ML24241A159 | |
| Person / Time | |
|---|---|
| Issue date: | 08/22/2024 |
| From: | Savara A Office of Nuclear Regulatory Research |
| To: | |
| References | |
| Download: ML24241A159 (1) | |
Text
1 of 3 SAVE THE DATE!
December 3-5, 2024 l Live Virtual Event The U.S. Nuclear Regulatory Commission (NRC) is organizing a Workshop on Storage and Transportation of TRISO and Metal Spent Nuclear Fuels. The workshop is being held in coordination with the U.S. Department of Energy Office of Nuclear Energy as well as the Electric Power Research Institute, with assistance from the Center for Nuclear Regulatory Waste Analyses.
Subject matter experts will give presentations and discuss current technical and regulatory considerations on storage and transportation of advanced reactor TRISO and metal spent fuels. The expert panels may include vendors, NRC staff, and researchers. The workshop attendance is open to the public. An expanded list of workshop topics is available on the following pages. A workshop website and call for submissions will be forthcoming.
Contacts: Aditya Savara (Aditya.Savara@nrc.gov)
- Patrick LaPlante (patrick.laplante@swri.org)
Jorge Narvaez (Jorge.Narvaez@nuclear.energy.gov)
- Daniel Moneghan (Moneghan@epri.com)
2 of 3 Expanded Topics for TRISO Spent Nuclear Fuels Storage and Transportation Physical Behavior of Fuel and Containers
- Structural Integrity o Matrix Fracture o Non-fuel Block Fracture o TRISO Particle Layer Fracture
- Materials Performance o PyC Creep and SiC fracture o Abrasive Wear o SiC Corrosion o Particle, Block, and Matrix Oxidation o Gas Pressurization (Including from Alpha Decay) o Fission Products Leaching o Fission Products Diffusion Nuclear Physics
- Considerations for Spent Fuel Safety o Decay Heat o Neutron multiplication and Criticality o Shielding and Radiation Protection Breakout Sessions: Current Regulations, Guidance Needs, and Crosscuts
- Provide Information on Current Regulations and Guides
- Assess Needs for New Guidance Development
- Discuss Crosscutting and Related Topics
[Expanded Topics for Metal Spent Nuclear Fuels Storage and Transportation on next page]
3 of 3 Expanded Topics for Metal Spent Nuclear Fuels Storage and Transportation Physical Behavior of Fuel and Containers
- Structural Integrity o Cladding Rupture Due to Pressurization o Fuel Swelling o Deformation
- Materials Performance o Corrosion o Reactions with Water (For Case with Na still in Spent Fuel) o Fission Products Leaching o Fission Products Diffusion o Fission Gas Generation and Release Nuclear Physics
- Considerations for Spent Fuel Safety o Decay Heat o Neutron Multiplication and Criticality o Shielding and Radiation Protection Breakout Sessions: Current Regulations, Guidance Needs, and Crosscuts
- Provide Information on Current Regulations and Guides
- Assess Needs for New Guidance Development
- Discuss Crosscutting and Related Topics