ML24222A861

From kanterella
Jump to navigation Jump to search
Attachment 2: HI-STORM 100 Amendment 19 Certificate of Compliance, Appendix D (Non-Proprietary)
ML24222A861
Person / Time
Site: Holtec
Issue date: 08/09/2024
From:
Holtec
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML24222A858 List:
References
5014982
Download: ML24222A861 (1)


Text

Approved Contents 2.0 Table 2.1-1 (page 2 of 4)

Fuel Assembly Limits Certificate of Compliance No. 1014 Appendix D Amendment No. 19 2-3 V. MPC MODEL: MPC-32M stored in HI-STORM 100S Version E SFSC (contd)

A. Allowable Contents (contd)

d. Decay Heat Per Fuel Storage Location:
i. Array/Classes 14x14D and 15x15G 500 Watts.

ii. All Other Array/Classes As specified in Section 2.4.

e. Fuel Assembly Length 176.8 inches (nominal design)
f. Fuel Assembly Width 8.54 inches (nominal design)
g. Fuel Assembly Weight 2,0501,520 lbs (including NON-FUEL HARDWARE)

ATTACHMENT 2 TO HOLTEC LETTER 5014982 Page 1 of 2

Certificate of Compliance No. 1014 Appendix D Proposed Amendment No. 19 2-5 Approved Contents 2.0 Table 2.1-1 (page 4 of 4)

Fuel Assembly Limits V. MPC MODEL: MPC-32M stored in HI-STORM 100S Version E SFSC (contd)

A. Allowable Contents (contd)

d. Decay Heat Per Fuel Storage Location:
i. Array/Classes 14x14D and 15x15G 500 Watts.

ii. All Other Array/Classes As specified in Section 2.4.

e. Fuel Assembly Length 176.8 inches (nominal design)
f. Fuel Assembly Width 8.54 inches (nominal design)
g. Fuel Assembly Weight 2,0501,520 lbs (including NON-FUEL HARDWARE and DFC)

B.

Quantity per MPC: Up to sixteen (16) DAMAGED FUEL ASSEMBLIES stored using DAMAGED FUEL ISOLATORS or DAMAGED FUEL CONTAINERS and/or FUEL DEBRIS in DAMAGED FUEL CONTAINERS, stored in fuel storage locations in Table 2.4-1. The remaining fuel storage locations may be filled with PWR UNDAMAGED FUEL ASSEMBLIES meeting the applicable specifications.

C.

One NSA is permitted for loading.

Note 1: Fuel assemblies containing BPRAs, TPDs, WABAs, water displacement guide tube plugs, orifice rod assemblies, or vibration suppressor inserts, with or without ITTRs, may be stored in any fuel storage location.

ATTACHMENT 2 TO HOLTEC LETTER 5014982 Page 2 of 2