EXPORT LICENSE NRC FORM 25 0 United States of America Nuclear Regulatory Commission Washington, D.C. 20555 NRC LICENSE NO.: PXB244.00 Page 1 of 3 NRC DOCKET NO.: 11006570 LICENSE EXPIRES: August 2, 2025 Pursuant to the Atomic Energy Act of 1954, as amended, and the regulations issued by the Nuclear Regulatory Commission (NRC) pursuant thereto, and in reliance on statements and representations heretofore made by the applicant/licensee, this license is hereby issued authorizing the licensee to export of the byproduct materials listed below, subject to the terms and conditions herein. This license is only valid if the licensee or 'Other Party (ies) to Export' maintain the requisite NRC or Agreement State domestic license(s).
LICENSEE Halliburton Energy Services 3000 N. Sam Houston Parkway E.
Houston, TX 77032 Attn: Kateri Noel INTERMEDIATE CONSIGNEE(S) IN FOREIGN COUNTRY(IES)
Special Cargo Services BV Breguetlaan 9 1438 BA Oude Meer Netherlands (freight forwarder)
APPLICANT'S
REFERENCE:
HES3459 ULTIMATE CONSIGNEE(S) IN FOREIGN COUNTRY(IES)
See following page(s)
OTHER U.S. PARTY(IES) TO EXPORT Halliburton Energy Services Inc.
14851 Milner Rd.
Gate 5 A Dock SR-1/SR-2 Houston, TX 77032 (exporter)
ULTIMATE DESTINATION: Iraq DESCRIPTIONS OF 10 CFR 110, APPENDIX P, BYPRODUCT MATERIALS TO BE EXPORTED, INCLUDING CONDITIONS AND NOTES (NOTE: SEE PAGE 2 FOR DEFINITIONS OF CATEGORY 1 AND CATEGORY 2)
Export to Iraq of specified quantities of Americium-241, Americium-241 /Beryllium, and Cesium-137, contained in sealed sources for use in oil and gas well logging operations is authorized. When combined for shipping, individual shipments may aggregate to a Category 2 quantity. See Page 2 for total number of sources and maximum activity levels for each source.
The sealed sources must remain in the custody of the authorized ultimate consignee at all times, and when not in use must be stored in a secure facility of the authorized ultimate consignee listed. Licensee is responsible for compliance with all applicable export, and other domestic regulatory requirements, including all terms and conditions of domestic material possession licenses.
Licensee must submit pertinent documentation required by 10 CFR 110.32(g) at least 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> prior to shipment. See Page 3 for Mandatory Advanced Notifications. Licensee shall submit by February 1 of each year one copy of a report of all americium shipments (under this license or under a general license) during the previous calendar year required by 10 CFR 110.54(b). The report must include: (1) a description of the material, including quantity; (2) approximate shipment dates; and (3) a list of recipient countries, end users, and intended use keyed to the items shipped.
License expiration date is based upon established time limits for a period of 1 year from license issuance.
Neither this license nor any right under this license shall be assigned or otherwise transferred in violation of the provisions of the Atomic Energy Act of 1954, as amended.
This license is subject to the right of recapture or control by Section 108 of the Atomic Energy Act of 1954, as amended, and to all the other provisions of said Acts, now or hereafter in effect and to all valid rules and regulations of the Nuclear Regulatory Commission.
THIS LICENSE IS INVALID UNLESS SIGNED BELOW BY AUTHORIZED NRC REPRESENTATIVE NAME AND TITLE:
Sabrina D. Atack, Deputy Director Office of International Programs DATE OF ISSUANCE: _A_ u_ g _u _st _2_, _20_2_4 _________ _
EXPORT LICENSE
ISOTOPE ACTIVITY PER SOURCE, TBq Quantity TOTAL ACTIVITY FOR ALL SOURCES, TBq END USE Am-241/Be
.6 12 7.2 Well Logging Am-241/Be
.888 12 Well Logging Cs-137
.555 15 8.33 Well Logging Cs-137 5.55 E-7 15 8.33 E-6 Well Logging Cs-137 9.3 E-8 15 1.40 E-Well Logging Am-241/Be 2.22 E-2 12 2.67 E-1 Well Logging Am-241/Be 1.48 E-2 12 1.78 E-1 Well Logging Am-241 0.00555 10 5.55 E-2 Well Logging Am-241 1.85 E-6 1.11 E-6 Well Logging