August 21, 2024 MEMORANDUM TO:

Josh Borromeo, Chief Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:

Cayetano Santos Jr., Senior Project Manager Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF JULY 22, 2024, MEETING WITH KAIROS ON THE LIMITATIONS AND CONDITIONS ASSOCIATED WITH KP-TR-013-P-A, METALLIC MATERIAL QUALIFICATION FOR THE KAIROS POWER FLOURIDE SALT-COOLED HIGH-TEMPERATURE REACTOR Meeting Information:

Applicant: Kairos Power LLC (Kairos)

Project No.: 99902069 Meeting Type: Partially Closed Observation Meeting Public Meeting Notice: Agencywide Documents Access and Management System (ADAMS)

Accession No.: ML24172A173 Applicant Presentation Slides: ML24183A408

Contact:

Cayetano Santos, NRR/DANU (301) 415-7270 CAYETA NO SANTOS Digitally signed by CAYETANO SANTOS Date: 2024.08.21 15:24:00 -04'00'

J. Borromeo 2

Meeting Summary:

On July 22, 2024, a virtual partially closed observation meeting was held between the U.S.

Nuclear Regulatory Commission (NRC) staff and representatives of Kairos. The purpose of the meeting was to discuss three of the limitations and conditions contained in KP-TR-013-P-A, Metallic Material Qualification for the Kairos Power Fluoride Salt-Cooled High-Temperature Reactor. Kairos representatives identified the 11 approved topical reports that directly support a future Hermes 1 operating license application and stated that closure plans for each of the limitations and conditions in these reports have been developed and will be summarized in the Hermes operating license application (ML24183A408).

Members of the public voiced no comments or questions.

Discussions between the NRC staff and Kairos representatives continued during a closed meeting to discuss detailed technical closure plans containing proprietary information.

Enclosure:

List of Attendees cc: Kairos Power Hermes via GovDelivery

J. Borromeo 3

SUBJECT:

SUMMARY

OF JULY 22, 2024, MEETING WITH KAIROS ON THE LIMITATIONS AND CONDITIONS ASSOCIATED WITH KP-TR-013-P-A, METALLIC MATERIAL QUALIFICATION FOR THE KAIROS POWER FLOURIDE SALT-COOLED HIGH-TEMPERATURE REACTOR DATED: AUGUST 21, 2024 DISTRIBUTION:

PUBLIC RidsACRS_MailCTR Resource RidsNrrDanuUal1 Resource RidsNrrDanu Resource JBorromeo, NRR CSantos, NRR DGreene, NRR MOrenak, NRR MHiser, NRR RBass, NRR JHoncharik, NRR AChereskin, NRR CdeMessieres, NRR PSawant, NRR ADAMS Accession Number: ML24204A132 NRR-109 OFFICE NRR/DANU/UAL1:PM NRR/DANU/UAL1:LA NRR/DANU/UAL1:BC NRR/DANU/UAL1:PM NAME CSantos DGreene JBorromeo CSantos DATE 7/22/2024 7/22/2024 8/21/2024 8/21/2024 OFFICIAL RECORD COPY

Enclosure List Of Attendees Summary Of Meeting with Kairos on the Limitations and Conditions Associated with KP-TR-013-P-A, Metallic Material Qualification for the Kairos Power Flouride Salt-Cooled High-Temperature Reactor July 22, 2024 Name Organization Cayetano Santos U.S. Nuclear Regulatory Commission (NRC)

Michael Orenak NRC Matthew Hiser NRC Alexander Chereskin NRC Ryann Bass NRC John Honcharik NRC Josh Borromeo NRC Candace de Messieres NRC Pravin Sawant NRC Jim Tomkins Kairos Power, LLC (Kairos)

Drew Peebles Kairos Darrell Gardner Kairos Brandon Haugh Kairos George Young Kairos John Price Kairos Gabriel Meric Kairos Mark Petkov Kairos Juan Pierre-Alexandre Kairos Micah Hackett Kairos Andrew Barbel Member of the Public Bridgette Hannifin Member of the Public Calen Kaneko Member of the Public David Farache Member of the Public Drew Fraser Member of the Public Jeff Koza-Reinders Member of the Public Marc Hotchkiss Member of the Public Greg Vetterick Member of the Public Robert Davis Member of the Public Spencer Toohill Member of the Public