Cimarron Environmental Response Trust, Updated Information Regarding Potential for Seepage in Burial Area 1
ML24191A451
Person / Time
Site: 07000925
Issue date: 07/09/2024
From: Lux J
Environmental Properties Management
To: James Smith
Office of Nuclear Material Safety and Safeguards, Document Control Desk
References
Download: ML24191A451 (1)


Text

Page 1 July 9, 2024 Mr. James Smith U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2738 Re: Docket No. 07000925; License No. SNM-928 Cimarron Environmental Response Trust Updated Information Regarding Potential for Seepage in Burial Area #1

Dear Recipients:

In a letter dated February 21, 2024, Environmental Properties Management LLC (EPM), solely as Trustee for the Cimarron Environmental Response Trust (CERT), submitted a response to a US Nuclear Regulatory Commission (NRC) concern. The issue raised was the potential for the injection of treated water in Injection Trench GWI-BA1-01 to generate sufficient groundwater mounding to cause groundwater to either 1) emerge from the surface between the injection trench and a drainage channel located approximately 150 feet east of the trench, or 2) discharge into the drainage channel (referred to in the February 21 submittal as an ephemeral stream).

After submitting that response, EPM discovered that the Comprehensive Analytical Data spreadsheet used to present uranium concentration data in the subject area did not contain all the analytical data that was in EPMs EQuIS database. In addition, when the Trustee Project Manager (Trustee PM) and a Radiation Protection technician (RP Tech) attempted to conduct a visual survey of the subject area, two problems were encountered:

1. Much of the area between the injection trench and the drainage channel was so heavily overgrown with underbrush that visual identification of emerging surface water is virtually impossible.
2. The drainage channel was discovered to be dammed in such a way that it is now essentially a pond that is at least a foot deep and 12-15 feet wide.

This submittal provides updated information on the concentration of uranium in groundwater in the southeastern portion of Burial Area #1 (BA1), work being performed that may clear the subject area, and the wetland survey performed in the area of the drainage channel. tabulates all the uranium concentration data for groundwater samples collected from those monitor wells in the southeastern portion of BA1. Attachment 2 is an image of the subject area. This figure was extracted from Figure GWRM 3-2 of the December 8, 2023, Response to October 2, 2023, Request for Additional Information (accession number ML23346A262). Attachment 2 categorizes recent uranium concentrations relative to the NRC Criterion (the Derived Concentration Guideline Level, or DCGL) of 180 picocuries per liter (pCi/L) and the State Criterion (the Maximum Contaminant Level, or MCL) of 30 micrograms

July 9, 2024 Response to NRC Concern Regarding Potential Seepage in Burial Area #1 Page 2 per liter (µg/L). In BA1 the mass concentration equivalent to 180 pCi/L is approximately 200

µg/L.

Review of the concentration trends for groundwater in the subject area indicates that as impacted groundwater migrates to the north, uranium concentrations have been declining in the subject area, and uranium concentrations in much of the area are not only well below the DCGL, but they may also now be below the State Criterion.

There are three monitor wells bordering the subject area (north of GWI-BA1-01) for which groundwater concentrations are near or slightly below the DCGL: Monitor Wells 02W40, 02W41, and 02W47. Unfortunately, the most recent uranium concentration data for these locations are for samples collected in 2018, 2017, and 2017, respectively. Based on the trend in uranium concentrations shown in Attachment 1, the concentration of uranium at all three locations may now be below the DCGL.

Safety-Related Impact from Injection of Treated Water shows the location of Injection Trench GWI-BA1-01 as a green dashed line. The area of concern is east of the injection trench, where blue dashed arrows indicate potential flow paths for groundwater (and treated water) during remediation activities. The locations of monitor wells north and east of the eastern end of GWI-BA1-01 are shown, along with the groundwater elevation, the approximate boundary of the flooded channel observed during the April 2024 wetland delineation activities, and the uranium concentration category for groundwater in each monitor well. Uranium concentration categories presented on this figure are:

Less than the MCL (< MCL)

Between the MCL and the DCGL (> MCL, < DCGL)

Greater than the DCGL (< DCGL)

As stated above, the uranium concentration categories shown in red font in Attachment 2 confirm that uranium concentrations in groundwater in much of the area now not only comply with the DCGL but are below the State Criterion.

Treated water containing uranium concentrations below the State Criterion will be injected into GWI-BA1-01. Because the injected water that will be flushing groundwater to the east, and the existing groundwater will both comply with NRC and State criteria, the injection of treated water presents no adverse impact from a radiological safety perspective.

Environmental Impact from Injection of Treated Water As discussed in the February 21 submittal, the injection of treated water into GWI-BA1-01 may result in either surface water seepage between the injection trench and the drainage channel, or in continuous discharge of water to the drainage channel.

July 9, 2024 Response to NRC Concern Regarding Potential Seepage in Burial Area #1 Page 3 EPM does not believe that either the creation of a surface water seep or the subsurface discharge of clean water to the impounded drainage channel represents an adverse environmental impact; however, NRC concerns regarding seepage or discharge to the drainage channel are recognized.

The February 21, 2024, letter proposed to have an Environmental/RP Tech conduct a visual survey of the subject area on a monthly basis, during routine radiological surveys conducted each month. However, the extremely thick undergrowth in the wooded area east of GWI-BA1-01 makes it impractical to visually observe seepage of groundwater to the surface in this area.

The ground surface slopes toward the east throughout this area, and any seepage of water to the surface would only flow to the impounded drainage channel. As a result, the continuous discharge of water into the channel would be unlikely to create a new wetland as it is already a surface water body. Consequently, EPM does not consider the seepage of groundwater to the surface in this area to create any adverse environmental impact.

EPM will request a cost estimate from Mills Construction, the company that provides mowing and brush clearing services for the site, for clearing the underbrush from the subject area. EPM will inform the NRC and the Oklahoma Department of Environmental Quality (DEQ) what it would cost to remove the underbrush and maintain the area. However, the removal of the undergrowth may present a more adverse environmental impact than the seepage of groundwater to the surface in this area.

If both the NRC and the DEQ believe that identifying seepage of groundwater to the surface is preferable to maintaining the existing undergrowth in this area, EPM will authorize Mills Construction to perform this brush clearing work.

Should the NRC or the DEQ desire additional clarification or information, EPM will be pleased to respond as soon as practical.

Sincerely, Jeff Lux Project Manager cc: (electronic copies only)

Stephanie Anderson and Linda Gersey, NRC Region IV Rachel Miller, Paul Davis, Keisha Cornelius, Pam Dizikes, David Cates, and Jon Reid, DEQ NRC Public Document Room vcpsubmittals@deq.ok.gov Jeff Lux

July 9, 2024 Response to NRC Concern Regarding Potential Seepage in Burial Area #1 ATTACHMENT 1 URANIUM CONCENTRATION DATA

Table 1a - Uranium Data Southeastern Portio of Burial Area #1 02W Series Monitor Wells Location Date Analyte Result Unit Qual Total U Uranium-234 1.45 pci/L Uranium-235 pci/L U

Uranium-238 0.649 pci/L Uranium-234 1.19 pci/L Uranium-235 pci/L U

Uranium-238 0.579 pci/L Uranium-234 3.35 pci/L Uranium-235 0.22 pci/L Uranium-238 2.01 pci/L Uranium-234 1.12 pci/L Uranium-235 0.0755 pci/L Uranium-238 0.638 pci/L Uranium-233/234 0.903 pci/L Uranium-235/236 0.109 pci/L Uranium-238 0.443 pci/L Uranium-234 0.436 pci/L U

Uranium-235

-0.0702 pci/L U

Uranium-238 0.702 pci/L Uranium-233/234 4.52 pci/L Uranium-235/236 0.812 pci/L Uranium-238 2.69 pci/L Uranium-233/234 0.989 pci/L Uranium-235/236 0.268 pci/L U

Uranium-238 1.16 pci/L Uranium-233/234 0.871 pci/L Uranium-235/236

-0.0251 pci/L U

Uranium-238 0.403 pci/L U

Uranium-233/234 1.65 pci/L Uranium-235/236 0.559 pci/L Uranium-238 1.08 pci/L Uranium-233/234 4.56 pci/L Uranium-235/236 0.218 pci/L U

Uranium-238 3.21 pci/L Uranium-235 0.0669 ug/L J

Uranium-238 6.63 ug/L J

Uranium-233/234 3.24 pci/L Uranium-235/236 0.432 pci/L Uranium-238 2.77 pci/L Uranium-235 0.0444 ug/L J

Uranium-238 4.09 ug/L U

02W09 6

2 2

6 1

2 8

1 1

2 3

7 8

2012-08-03 2011-08-17 2010-10-18 2009-05-28 2004-09-02 2002-08-26 2017-05-02 2018-06-13 2016-05-10 2015-03-25 2014-05-28 2013-05-14 4

Prepared by: Jeff Lux Date: 5/24/2024 Reviewed by : Matt Crawford Date: 6/28/2024 Page 1 of 9

Table 1a - Uranium Data Southeastern Portio of Burial Area #1 02W Series Monitor Wells Location Date Analyte Result Unit Qual Total U Uranium-235 0.0139 ug/L J

Uranium-238 1.59 ug/L Uranium-233/234 5.12 pci/L Uranium-235/236 0.635 pci/L U

Uranium-238 1.89 pci/L Uranium-235 0.0301 ug/L J

Uranium-238 3.07 ug/L Uranium-233/234 0.994 pci/L Uranium-235/236 0.18 pci/L U

Uranium-238 0.941 pci/L Uranium-235 0.0259 ug/L J

Uranium-238 2.31 ug/L Uranium-233/234 3.55 pci/L Uranium-235/236 0.093 pci/L U

Uranium-238 2.49 pci/L Uranium-235 0.0854 ug/L Uranium-238 7.71 ug/L Uranium-233/234 1.03 pci/L Uranium-235/236 0.137 pci/L U

Uranium-238 0.839 pci/L Uranium-235 0.0208 ug/L J

Uranium-238 2.2 ug/L Uranium-233/234 1.23 pci/L Uranium-235/236 0.0469 pci/L U

Uranium-238 0.75 pci/L Uranium-235 0.033 ug/L J

Uranium-238 3.23 ug/L Uranium-235 0.0268 ug/L J

Uranium-238 2.91 ug/L Uranium-234 1.29 pci/L Uranium-235 pci/L U

Uranium-238 0.835 pci/L Uranium-234 0.778 pci/L Uranium-235 0.168 pci/L J

Uranium-238 0.602 pci/L J

Uranium-233/234 0.156 pci/L U

Uranium-235/236

-0.0257 pci/L U

Uranium-238 0.153 pci/L U

Uranium-233/234 0.683 pci/L Uranium-235/236 0.186 pci/L U

Uranium-238 0.411 pci/L U

02W20 2

3 2

2 2

8 1

0 2

2 2

3 8

2 2023-07-13 2022-07-14 2021-07-06 2020-07-22 2019-08-27 2015-03-25 2013-05-21 2004-09-07 2002-08-26 6

2018-09-17 3

2024-04-17 02W09 (continued)

Prepared by: Jeff Lux Date: 5/24/2024 Reviewed by : Matt Crawford Date: 6/28/2024 Page 2 of 9

Table 1a - Uranium Data Southeastern Portio of Burial Area #1 02W Series Monitor Wells Location Date Analyte Result Unit Qual Total U Uranium-235 0.0155 ug/L J

Uranium-238 1.53 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.547 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.981 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.674 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.494 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.746 ug/L Uranium-235 0.0113 ug/L J

Uranium-238 1.31 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.817 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.435 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.647 ug/L Uranium-235 0.01 ug/L J

Uranium-238 1.36 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.83 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.355 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.493 ug/L Uranium-235 0.01 ug/L U

Uranium-238 0.551 ug/L Uranium-234 8.24 pci/L Uranium-235 pci/L U

Uranium-238 4.2 pci/L Uranium-234 1.36 pci/L Uranium-235 pci/L U

Uranium-238 0.71 pci/L Uranium-233/234 3.49 pci/L Uranium-235/236 0.153 pci/L U

Uranium-238 1.93 pci/L 02W20 (continued) 02W26 6

2 12 1

1 1

1 1

2 0

1 1

1 0

1 1

1 1

2020-07-16 2020-04-16 2019-01-31 2018-09-17 2017-04-25 2020-10-12 2021-10-14 2021-07-15 2021-04-15 2021-01-22 2013-05-21 2004-09-07 2002-08-26 2023-07-21 2022-10-20 2022-07-08 2022-04-20 2022-01-19 Prepared by: Jeff Lux Date: 5/24/2024 Reviewed by : Matt Crawford Date: 6/28/2024 Page 3 of 9

Table 1a - Uranium Data Southeastern Portio of Burial Area #1 02W Series Monitor Wells Location Date Analyte Result Unit Qual Total U Uranium-233/234 0.966 pci/L Uranium-235/236 0.0771 pci/L U

Uranium-238 0.385 pci/L Uranium-235 0.0263 ug/L J

Uranium-238 2.74 ug/L Uranium-234 921 pci/L Uranium-235 120 pci/L X

Uranium-238 525 pci/L Uranium-234 1050 pci/L Uranium-235 114 pci/L Uranium-238 681 pci/L Uranium-233/234 869 pci/L Uranium-235/236 48.7 pci/L Uranium-238 617 pci/L Uranium-233/234 392 pci/L Uranium-235/236 25.2 pci/L Uranium-238 246 pci/L Uranium-235 8.16 ug/L Uranium-238 727 ug/L Uranium-235 6.31 ug/L Uranium-238 534 ug/L Uranium-235 5.49 ug/L Uranium-238 454 ug/L Uranium-235 5.93 ug/L Uranium-238 471 ug/L Uranium-235 5.35 ug/L Uranium-238 434 ug/L Uranium-235 6.9 ug/L Uranium-238 596 ug/L Uranium-235 4.78 ug/L Uranium-238 373 ug/L Uranium-235 4.73 ug/L Uranium-238 345 ug/L Uranium-235 4.81 ug/L Uranium-238 361 ug/L Uranium-235 3.44 ug/L Uranium-238 259 ug/L Uranium-235 4.95 ug/L Uranium-238 367 ug/L 02W26 (continued) 02W29 / TR-10 3

2021-04-15 2021-01-21 1

735 663 1,535 1,845 365.81 1,566 349.73 377.78 602.9 439.35 476.93 459.49 540.31 371.95 262.44 2019-08-29 2015-03-25 2013-05-28 2004-09-07 2019-01-31 2018-09-17 2018-08-24 2017-12-04 2017-04-25 2002-08-27 2017-04-25 2015-03-25 2020-10-12 2020-07-16 2020-04-16 Prepared by: Jeff Lux Date: 5/24/2024 Reviewed by : Matt Crawford Date: 6/28/2024 Page 4 of 9

Table 1a - Uranium Data Southeastern Portio of Burial Area #1 02W Series Monitor Wells Location Date Analyte Result Unit Qual Total U Uranium-235 4.42 ug/L Uranium-238 341 ug/L Uranium-235 3.79 ug/L Uranium-238 283 ug/L Uranium-235 3.38 ug/L Uranium-238 264 ug/L Uranium-235 3.08 ug/L Uranium-238 222 ug/L Uranium-235 3.56 ug/L Uranium-238 255 ug/L Uranium-235 2.3 ug/L Uranium-238 179 ug/L Uranium-235 3.54 ug/L Uranium-238 255 ug/L Uranium-234 559 pci/L Uranium-235 46.2 pci/L X

Uranium-238 329 pci/L Uranium-234 741 pci/L J

Uranium-235 39.7 pci/L J

Uranium-238 429 pci/L J

Uranium-233/234 436 pci/L Uranium-235/236 26.8 pci/L Uranium-238 228 pci/L Uranium-233/234 353 pci/L Uranium-235/236 17.7 pci/L Uranium-238 197 pci/L Uranium-235 4.34 ug/L Uranium-238 340 ug/L Uranium-235 4.74 ug/L Uranium-238 378 ug/L Uranium-235 4.81 ug/L Uranium-238 387 ug/L Uranium-235 3.76 ug/L Uranium-238 305 ug/L Uranium-235 2.94 ug/L Uranium-238 231 ug/L Uranium-235 5.83 ug/L Uranium-238 429 ug/L Uranium-235 2.99 ug/L Uranium-238 229 ug/L 02W29 / TR-10 (continued) 02W39 232 435 234 309 392 383 344 2022-01-19 2021-10-14 2021-07-15 2018-02-07 2017-11-08 568 691 1,210 934 258.54 181.3 258.56 225.08 267.38 286.79 345.42 2023-07-21 2022-10-20 2022-07-08 2022-04-20 2017-08-03 2017-04-25 2017-02-08 2015-03-25 2013-05-28 2004-09-08 2002-08-26 2018-08-24 2018-05-08 Prepared by: Jeff Lux Date: 5/24/2024 Reviewed by : Matt Crawford Date: 6/28/2024 Page 5 of 9

Table 1a - Uranium Data Southeastern Portio of Burial Area #1 02W Series Monitor Wells Location Date Analyte Result Unit Qual Total U Uranium-235 1.75 ug/L Uranium-238 136 ug/L Uranium-235 1.81 ug/L Uranium-238 134 ug/L Uranium-235 2.9 ug/L Uranium-238 220 ug/L Uranium-235 2.63 ug/L Uranium-238 198 ug/L Uranium-235 2.81 ug/L Uranium-238 211 ug/L Uranium-235 2.35 ug/L Uranium-238 176 ug/L Uranium-235 2.21 ug/L Uranium-238 170 ug/L Uranium-235 2.14 ug/L Uranium-238 157 ug/L Uranium-235 2.06 ug/L Uranium-238 158 ug/L Uranium-235 2.25 ug/L Uranium-238 170 ug/L Uranium-235 2.24 ug/L Uranium-238 174 ug/L Uranium-235 4

ug/L Uranium-238 294 ug/L Uranium-235 4.21 ug/L Uranium-238 297 ug/L Uranium-235 5.07 ug/L Uranium-238 365 ug/L Uranium-235 5.25 ug/L Uranium-238 373 ug/L Uranium-235 1.91 ug/L Uranium-238 141 ug/L Uranium-235 1.9 ug/L Uranium-238 144 ug/L Uranium-235 2.17 ug/L Uranium-238 174 ug/L Uranium-235 2.16 ug/L Uranium-238 172 ug/L 02W39 (continued) 160 159 378 370 301 298 176 172 174 176 146 143 2021-01-22 2020-10-19 214 201 223 136 138 172 178 2021-04-15 2020-04-16 2018-11-07 2018-09-17 2022-01-19 2021-10-14 2021-07-15 2020-07-16 Prepared by: Jeff Lux Date: 5/24/2024 Reviewed by : Matt Crawford Date: 6/28/2024 Page 6 of 9

Table 1a - Uranium Data Southeastern Portio of Burial Area #1 02W Series Monitor Wells Location Date Analyte Result Unit Qual Total U Uranium-235 2.13 ug/L Uranium-238 164 ug/L Uranium-235 2.1 ug/L Uranium-238 159 ug/L Uranium-235 2.05 ug/L Uranium-238 163 ug/L Uranium-235 2.01 ug/L Uranium-238 155 ug/L Uranium-235 1.47 ug/L 112 Uranium-238 111 ug/L Uranium-235 3.56 ug/L 260 Uranium-238 256 ug/L Uranium-234 825.00 pci/L Uranium-235 51.60 pci/L X

Uranium-238 456.00 pci/L Uranium-234 917.00 pci/L Uranium-235 77.00 pci/L Uranium-238 716.00 pci/L Uranium-234 1240.00 pci/L Uranium-235 98.10 pci/L Uranium-238 583.00 pci/L Uranium-233/234 962.00 pci/L Uranium-235/236 51.90 pci/L Uranium-238 577.00 pci/L Uranium-233/234 556.00 pci/L Uranium-235/236 37.30 pci/L Uranium-238 309.00 pci/L Uranium-235 10.60 ug/L Uranium-238 831.00 ug/L Uranium-235 12.40 ug/L Uranium-238 1000.00 ug/L Uranium-235 9.06 ug/L Uranium-238 743.00 ug/L Uranium-235 6.44 ug/L Uranium-238 480.00 ug/L Uranium-235 2.35 ug/L Uranium-238 158.00 ug/L Uranium-235 2.29 ug/L Uranium-238 152.00 ug/L 02W39 (continued) 02W40 1,591 1,921 1,710 154 160 486 752 1,012 842 902 157 165 1,333 161 166 2023-07-21 2022-10-20 2022-07-08 2022-04-20 2018-05-08 2018-02-07 2017-11-08 2017-08-03 2017-04-25 2017-02-08 2015-03-25 2013-05-21 2004-09-08 2002-08-26 Prepared by: Jeff Lux Date: 5/24/2024 Reviewed by : Matt Crawford Date: 6/28/2024 Page 7 of 9

Table 1a - Uranium Data Southeastern Portio of Burial Area #1 02W Series Monitor Wells Location Date Analyte Result Unit Qual Total U Uranium-235 3.06 ug/L Uranium-238 197.00 ug/L Uranium-235 3.61 ug/L Uranium-238 231.00 ug/L Uranium-234 593.00 pci/L Uranium-235 33.00 pci/L Uranium-238 342.00 pci/L Uranium-234 616.00 pci/L Uranium-235 58.10 pci/L X

Uranium-238 313.00 pci/L Uranium-234 601.00 pci/L J

Uranium-235 32.90 pci/L J

Uranium-238 332.00 pci/L J

Uranium-233/234 306.00 pci/L Uranium-235/236 16.40 pci/L Uranium-238 167.00 pci/L Uranium-233/234 223.00 pci/L Uranium-235/236 12.30 pci/L Uranium-238 112.00 pci/L Uranium-235 4.82 ug/L Uranium-238 349.00 ug/L Uranium-234 139.00 pci/L Uranium-235 14.80 pci/L Uranium-238 81.30 pci/L Uranium-234 164.00 pci/L Uranium-235 9.92 pci/L Uranium-238 92.40 pci/L Uranium-234 245.00 pci/L Uranium-235 15.80 pci/L Uranium-238 115.00 pci/L Uranium-234 667.00 pci/L Uranium-235 38.70 pci/L J

Uranium-238 296.00 pci/L Uranium-234 920.00 pci/L Uranium-235 51.40 pci/L J

Uranium-238 316.00 pci/L J

Uranium-233/234 368.00 pci/L Uranium-235/236 21.00 pci/L Uranium-238 119.00 pci/L 02W40 (continued) 02W47 02W41 987 508 1,287 1,002 376 266 235 354 347 489 966 235 200 968 2008-06-18 2007-08-15 2013-05-21 2004-08-25 2002-08-26 2017-04-25 2015-03-25 2013-05-21 2004-09-08 2002-08-26 2018-11-07 2018-08-24 Prepared by: Jeff Lux Date: 5/24/2024 Reviewed by : Matt Crawford Date: 6/28/2024 Page 8 of 9

Table 1a - Uranium Data Southeastern Portio of Burial Area #1 02W Series Monitor Wells Location Date Analyte Result Unit Qual Total U Uranium-233/234 167.00 pci/L Uranium-235/236 7.42 pci/L Uranium-238 77.80 pci/L Uranium-235 3.74 ug/L Uranium-238 162.00 ug/L Uranium-234 2.80 pci/L Uranium-235 0.19 pci/L Uranium-238 2.03 pci/L Uranium-234 2.12 pci/L Uranium-235 0.12 pci/L Uranium-238 1.26 pci/L Uranium-233/234 2.38 pci/L Uranium-235/236 0.10 pci/L U

Uranium-238 1.01 pci/L Uranium-233/234 1.99 pci/L Uranium-235/236

-0.02 pci/L U

Uranium-238 0.76 pci/L Uranium-234 2.24 pci/L Uranium-235 pci/L U

Uranium-238 1.58 pci/L Uranium-234 1.13 pci/L Uranium-235 0.15 pci/L Uranium-238 0.67 pci/L Uranium-233/234 1.51 pci/L Uranium-235/236 0.07 pci/L U

Uranium-238 0.46 pci/L Uranium-233/234 1.37 pci/L Uranium-235/236 0.06 pci/L U

Uranium-238 0.62 pci/L Notes: pci/L - picocuries per liter ug/L - migrograms per liter U - Undetected J - Estimated Value X - Questionable Value Based on Reasonableness Review 2

2 2

4 3

3 166 252 4

5 02W47 (continued) 02W50 02W52 2015-03-25 2013-05-21 2004-09-08 2002-08-26 2015-03-25 2013-05-21 2004-09-08 2002-08-26 2017-04-25 2015-03-25 Prepared by: Jeff Lux Date: 5/24/2024 Reviewed by : Matt Crawford Date: 6/28/2024 Page 9 of 9

July 9, 2024 Response to NRC Concern Regarding Potential Seepage in Burial Area #1 ATTACHMENT 2 SOUTHEASTERN AREA OF BA1