PMNS20240863, Pre-submittal Meeting with Virginia Electric and Power Company (VEPCO) to Discuss Its Proposed License Amendment for Surry Power Station, Units 1 and 2

From kanterella
(Redirected from ML24179A289)
Jump to navigation Jump to search

Pre-submittal Meeting with Virginia Electric and Power Company (VEPCO) to Discuss Its Proposed License Amendment for Surry Power Station, Units 1 and 2
ML24179A289
Person / Time
Site: Surry  
Issue date: 06/27/2024
From:
Office of Nuclear Reactor Regulation
To:
References
PMNS20240863
Download: ML24179A289 (2)


Text

June 27, 2024

Title:

Pre-submittal meeting with Virginia Electric and Power Company (VEPCO) to discuss its proposed license amendment for Surry Power Station, Units 1 and 2.

July 17, 2024, 01:00 PM to 03:00 PM ET Date(s) and Time(s):

Location:

Teleconference Category:

This is an Observation Meeting. This is a meeting in which attendees will have an opportunity to observe the NRC performing its regulatory function or discussing regulatory issues. Attendees will have an opportunity to ask questions of the NRC staff or make comments about the issues discussed following the business portion of the meeting; however, the NRC is not actively soliciting comments towards regulatory decisions at this meeting.

Purpose:

The purpose of this meeting is for VEPCO to discuss its proposed amendments to Technical Specifications (TS) 3.7, Instrumentation Systems, and TS 3.14, Circulating and Service Water Systems, at Surry Power Station, Unit 1 and 2. The licensee proposes to extend the allowed outage times and use temporary equipment to complete maintenance and apply carbon fiber-reinforced polymer on the inside surface of service water system piping.

Contact:

John Klos 301-415-5136 John.Klos@nrc.gov Ed Miller 301-415-2481 Ed.Miller@nrc.gov NRC Office of Nuclear Reactor Regulation

Participants:

External Gary Miller, Virginia Electric and Power Company Teleconference:

Webinar:

URL Meeting Number Password https://teams.microsoft.

com/meetingOptions/?

organizerId=342e2c29-8327-4f1b-862d-2163e908ac35&tenantId=e8d01475-c3b5-436a-a065-5def4c64f52e&threadId=19_meeting_NmI5 NmZhZDgtMDM3ZC00ZjE2LWJjOTYtMTFk MTFjY2FjZDk1@thread.

v2&messageId=0&language=en-US 301-576-2978 577 970 119#

Docket No:

05000280 05000281 The NRC provides reasonable accommodations to individuals with disabilities where appropriate. If you need a reasonable accommodation due to a disability to participate in a meeting or need a meeting notice or the transcript or other information from a meeting in another format (e.g. braille, large print), please email Reasonable_Accommodations.Resource@nrc.gov. Determinations on requests for reasonable accommodation will be made on a case-by-case basis and the agency may choose between effective accommodations to provide. At least ten (10) days advance notice is recommended in order for a request for accommodation to be processed and implemented if approved. However, every effort will be made to address any reasonable accommodations requests received with less notice.

PUBLIC MEETING AGENDA

Pre-submittal meeting with Virginia Electric and Power Company (VEPCO) to discuss its proposed license amendment for Surry Power Station, Units 1 and 2.

July 17, 2024, 01:00 PM to 03:00 PM ET Teleconference

ADAMS Accession Number: ML24179A289 Distribution:

Office NRR/DORL/LPL2-1/PM NRR/DORL/LPL2-1/BC NRR/DORL/LPL2-1/LA NRR/DORL/LPL2-1/PM Name John Klos Kay Goldstein Mike Markley John Klos Date 06/26/2024 06/26/2024 06/27/2024 06/27/2024 OFFICIAL RECORD COPY https://www.nrc.gov/pmns/mtg?do=details&Code=20240863 Link to meeting details:

Commission's Policy Statement on "Enhancing Public Participation in NRC Meetings" 86 FR 14964, March 19, 2021 ADAMS No. ML21050A046 https://www.nrc.gov/reading-rm/doc-collections/commission/policy/index.html