June 5, 2024 MEMORANDUM TO:

Josh Borromeo, Chief Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:

Matthew A. Hiser, Senior Project Manager /RA/

Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF THE APRIL 23, 2024, OPEN OBSERVATION PUBLIC MEETING TO DISCUSS ASME CODE RECORD 23-15:

ALTERNATE RULES FOR NON-DESTRUCTIVE EXAMINATION AND TESTING OF ASME SECTION III NUCLEAR ITEMS Meeting Information:

Industry Organization: Nuclear Energy Institute Project No.: 99902028 Meeting Type: Open Observation Public Meeting Notice: Agencywide Documents Access and Management System (ADAMS)

Accession No.: ML24114A002 Industry Presentation Slides and Information: ML24113A217 (package)

Meeting Attendees: See Enclosure for list of meeting attendees.

J. Borromeo 2

Meeting Summary The U.S. Nuclear Regulatory Commission (NRC) staff conducted the meeting in accordance with NRC Management Directive 3.5, Attendance at NRC Staff-Sponsored Meetings (ML21180A271).

On April 23, 2024, the NRC staff held a public meeting with the Nuclear Energy Institute (NEI) to discuss American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC) Record 23-15, which addresses proposed alternate rules for non-destructive examination and testing of ASME BPVC Section III nuclear items commensurate with an items contribution to safety or risk. Participants included representatives from NEI, MPR Associates, Westinghouse, Curtiss Wright, and Holtec. The NRC staff began the public meeting with introductions and an explanation of logistical information.

During the meeting, representatives from NEI and MPR Associates provided a presentation covering the basis and motivation for ASME Code Record 23-15. Their presentation also covered the current status of ASME Code Record 23-15 and facilitated a discussion with NRC staff on various topics associated with prior NRC comments on Record 23-15. During the discussion, NRC staff indicated that they intend to capture a position on Record 23-15 in the next revision to Regulatory Guide 1.87, Acceptability of ASME Code Section III, Division 5, High Temperature Reactors', Revision 2 (ML22101A233). The Code Case authors indicated that they would consider the feedback provided by NRC staff during the meeting and potentially revise the Code Case leading up to the May ASME BPVC Code Week.

Topics discussed in more detail during the meeting include:

the scope of systems, structures, and components (SSCs) to be covered by Record 23-15, the definition of moderate energy piping for different reactor technologies, how the rules in Record 23-15 interface with other ASME BPVC rules associated with piping containing hazardous substances, the trade-offs between inspection and quality assurance and design allowables in Section III, Division 5 and Section VIII, consideration of augmented rules around the use of ultrasonic testing (UT) within Record 23-15, such as encoded UT and flaw acceptance criteria, clarification that Record 23-15 was revised earlier in 2024 to have ultrasonic inspection as an alternative to radiography only be applicable to piping and supports, but not

vessels, the appropriate level of inspection sampling for this class of SSCs based on risk and safety significance, and topics of potential conditions if NRC staff endorses this Code Case in the future.

The public had an opportunity to ask questions of the NRC staff at the end of the meeting.

A representative from Curtiss Wright inquired about a report from the Electric Power Research Institute (EPRI) supporting Record 23-15. A response was provided that this was referring to EPRI report number 3002023907, titled Alternate Requirements for Construction of ASME Section III Division 5 Components Commensurate with their Contribution to Safety and Risk.

A representative from SMR, LLC inquired about the scope of these rules and whether they would be applicable to light water reactors (LWRs). A response was provided that this action is within ASME BPVC Section III, Division 5, which is only applicable to non-LWRs.

J. Borromeo 3

CONTACT: Matthew A. Hiser, NRR/DANU (301) 415-2454

Enclosure:

List of Meeting Attendees

J. Borromeo 4

SUBJECT:

SUMMARY

OF THE APRIL 23, 2024, OPEN OBSERVATION PUBLIC MEETING TO DISCUSS ASME CODE RECORD 23-15: ALTERNATE RULES FOR NON-DESTRUCTIVE EXAMINATION AND TESTING OF ASME SECTION III NUCLEAR ITEMS DATED: JUNE 5, 2024 DISTRIBUTION:

PUBLIC MHiser, NRR JBorromeo, NRR DGreene, NRR KManoly, NRR MAudrain, NRR AChereskin, NRR DRudland, NRR BLin, NRR JHoncharik, NRR NHansing, NRR RBass, NRR JBass, RES CdeMessieries, NRR GOberson, NRR RIyengar, RES TSham, RES SCumblidge, NRR ADAMS Accession Number:

ML24156A173 NRR-109 OFFICE NRR/DANU/UAL1/PM NRR/DANU/UAL1/BC NRR/DANU/UAL1/PM NAME MHiser JBorromeo (SDevlin-Gill for)

MHiser DATE 5/ 30 /2024 06/03/2024 6/ 05 /2024 OFFICIAL RECORD COPY

Enclosure List of Attendees Open Observation Meeting to Discuss ASME Code Record 23-15: Alternate Rules for Non-Destructive Examination and Testing of ASME Section III Nuclear Items April 23, 2024 Name Organization Matthew Hiser U.S. Nuclear Regulatory Commission (NRC)

Ting-Leung Sham NRC Kamal Manoly NRC Meg Audrain NRC Alexander Chereskin NRC David Rudland NRC Joe Bass NRC Ryann Bass NRC Bruce Lin NRC John Honcharik NRC Candace de Messieres NRC Michael Fitzgerald NRC Nicholas Hansing NRC Raj Iyengar NRC Matthew Mitchell NRC Greg Oberson NRC Chakrapani Basavaraju NRC Stephen Cumblidge NRC Tom Basso Nuclear Energy Institute Suzanne McKillop MPR Associates Rachel Romano MPR Associates Robert Keating MPR Associates Zefeng Yu Westinghouse Clark Shurtleff SMR, LLC (Holtec)

Jana Bergman Curtiss Wright