Case #0 Expande d region created on Mon Sep 28 16:21:27 2020 OD
[inches]
t [inches]
Weld Width
[inches]
Inlay 1 =
Yes Inlay Thicknes s [inches]
a_0inche s]
2c_0inch es]
Temp Pressure Axial Bending 100 0
0.3575 0
0 a/t WRS 0
Results Time Units:
Month Flaw Size Units:
inches Time @
a/t = 0.75 Time at Leakage Leakage Size (ID length)
Time at Rupture Rupture Size (ID Length) 75 Months 89 Months 0.9 inches N/A Calculatio n
Stopped at 2c_OD
= 7.4 inches Time
[Month]
a [mm]
c(ID)
[mm]
c(OD)
[mm]
Ka Kc(ID)
Kc(OD) a/t 2c(ID)/a 2c(OD)/C rownWidt h
0 0
16.397 8.531 0
0.1 0
1 0
16.397 8.531 0
0.104 0
2 0
16.65 8.846 0
0.107 0
3 0
16.903 9.172 0
0.111 0
4 0
17.157 9.508 0
0.116 0
5 0
17.411 9.853 0
0.12 0
6 0
17.664 10.207 0
0.124 0
7 0
17.916 10.568 0
0.129 0
8 0
18.167 10.937 0
0.133 0
9 0
18.415 11.312 0
0.138 0
10 0
18.661 11.693 0
0.143 0
11 0
18.904 12.08 0
0.148 0
12 0
19.143 12.471 0
0.154 0
13 0
19.379 12.866 0
0.159 0
14 0
19.611 13.264 0
0.165 0
15 0
19.84 13.666 0
0.17 0
16 0
20.063 14.069 0
0.176 0
17 0
20.283 14.473 0
0.182 0
18 0
20.499 14.879 0
0.188 0
19 0
20.71 15.284 0
0.195 0
20 0
20.918 15.69 0
0.201 0
21 0
21.121 16.095 0
0.207 0
22 0
21.321 16.499 0
0.214 0
23 0
21.518 16.902 0
0.221 0
Proprietary info is highlighted
24 0
21.712 17.303 0
0.228 0
25 0
21.903 17.703 0
0.235 0
26 0
22.091 18.101 0
0.242 0
27 0
22.277 18.496 0
0.249 0
28 0
22.461 18.889 0
0.256 0
29 0
22.644 19.28 0
0.264 0
30 0
22.826 19.668 0
0.271 0
31 0
23.006 20.054 0
0.279 0
32 0
23.186 20.438 0
0.287 0
33 0
23.366 20.819 0
0.295 0
34 0
23.546 21.198 0
0.303 0
35 0
23.726 21.574 0
0.311 0
36 0
23.906 21.948 0
0.319 0
37 0
24.087 22.32 0
0.327 0
38 0
24.269 22.69 0
0.336 0
39 0
24.451 23.058 0
0.344 0
40 0
24.635 23.424 0
0.353 0
41 0
24.821 23.789 0
0.362 0
42 0
25.008 24.151 0
0.371 0
43 0
25.196 24.512 0
0.38 0
44 0
25.387 24.871 0
0.389 0
45 0
25.579 25.229 0
0.399 0
46 0
25.773 25.585 0
0.408 0
47 0
25.97 25.939 0
0.418 0
48 0
26.175 26.292 0
0.427 0
49 0
26.384 26.644 0
0.437 0
50 0
26.598 26.994 0
0.447 0
51 0
26.816 27.342 0
0.457 0
52 0
27.038 27.689 0
0.468 0
53 0
27.264 28.034 0
0.478 0
54 0
27.494 28.376 0
0.489 0
55 0
27.728 28.717 0
0.5 0
56 0
27.965 29.054 0
0.51 0
57 0
28.207 29.388 0
0.522 0
58 0
28.452 29.719 0
0.533 0
59 0
28.702 30.045 0
0.544 0
60 0
28.955 30.366 0
0.556 0
61 0
29.212 30.682 0
0.568 0
62 0
29.472 30.99 0
0.579 0
63 0
29.737 31.291 0
0.592 0
64 0
30.005 31.582 0
0.604 0
65 0
30.276 31.863 0
0.616 0
66 0
30.551 32.131 0
0.629 0
67 0
30.829 32.385 0
0.642 0
68 0
31.11 32.623 0
0.655 0
69 0
31.395 32.843 0
0.668 0
70 0
31.681 33.041 0
0.682 0
71 0
31.971 33.214 0
0.695 0
72 0
32.262 33.36 0
0.709 0
73 0
32.554 33.474 0
0.723 0
74 0
32.848 33.552 0
0.737 0
75 0
33.143 33.589 0
0.752 0
76 0
33.437 33.58 0
0.766 0
77 0
33.73 33.517 0
0.781 0
78 0
34.021 33.395 0
0.796 0
79 0
34.309 33.205 0
0.811 0
80 0
34.593 32.939 0
0.827 0
81 0
34.871 32.588 0
0.843 0
82 0
35.142 32.14 0
0.858 0
83 0
35.403 31.584 0
0.874 0
84 0
35.652 30.908 0
0.891 0
85 0
35.887 30.099 0
0.907 0
86 0
36.105 29.144 0
0.923 0
87 0
36.303 28.028 0
0.94 0
88 0
36.476 26.741 0
0.957 0
89 2.793 0
0 0
1 0.002 90 3.272 0
49.737 82.822 1
0.003 91 3.796 0
50.916 88.707 1
0.003 92 4.362 0
52.027 94.172 1
0.003 93 4.968 0
53.077 99.322 1
0.004 94 5.613 0
54.124 104.339 1
0.004 95 6.297 0
55.181 109.298 1
0.005 96 7.021 0
56.251 114.253 1
0.006 97 7.762 0
57.428 116.548 1
0.006 98 8.523 0
58.627 118.874 1
0.007 99 9.305 0
59.842 121.571 1
0.007 100 10.109 0
61.16 124.247 1
0.008 101 10.868 0
64.386 118.792 1
0.009 102 11.598 0
67.328 115.057 1
0.009 103 12.308 0
70.115 112.498 1
0.01 104 13.004 0
72.824 110.795 1
0.01 105 13.691 0
75.506 109.748 1
0.011 106 14.375 0
78.196 109.227 1
0.011 107 15.058 0
80.923 109.144 1
0.012 108 15.743 0
83.708 109.439 1
0.012 109 16.433 0
86.569 110.069 1
0.013 110 17.131 0
89.524 111.006 1
0.013 111 17.838 0
92.587 112.23 1
0.014 112 18.557 0
95.781 113.704 1
0.015 113 19.289 0
99.14 115.368 1
0.015 114 20.037 0
102.643 117.336 1
0.016 115 21.647 0
108.659 108.659 1
0.017 116 22.356 0
112.359 112.359 1
0.018 117 23.095 0
116.276 116.276 1
0.018 118 23.868 0
120.428 120.428 1
0.019 119 24.677 0
124.832 124.832 1
0.019 120 25.523 0
129.511 129.511 1
0.02 121 26.41 0
134.487 134.487 1
0.021 122 27.341 0
139.786 139.786 1
0.021 123 28.318 0
145.435 145.435 1
0.022 124 29.346 0
151.466 151.466 1
0.023 125 30.428 0
157.913 157.913 1
0.024 126 31.569 0
164.812 164.812 1
0.025 127 32.772 0
172.204 172.204 1
0.026 128 34.043 0
180.135 180.135 1
0.027 129 35.388 0
188.654 188.654 1
0.028 130 36.813 0
197.816 197.816 1
0.029 131 38.325 0
207.68 207.68 1
0.03 132 39.931 0
218.313 218.313 1
0.031 133 41.64 0
229.786 229.786 1
0.033 134 43.46 0
242.177 242.177 1
0.034 135 45.402 0
255.573 255.573 1
0.036 136 47.477 0
270.066 270.066 1
0.037 137 49.697 0
285.755 285.755 1
0.039
138 52.077 0
302.749 302.749 1
0.041 139 54.63 0
321.163 321.163 1
0.043 140 57.374 0
341.119 341.119 1
0.045 141 60.325 0
362.748 362.748 1
0.047 142 63.505 0
386.187 386.187 1
0.05 143 66.935 0
411.581 411.581 1
0.052 144 70.638 0
439.086 439.086 1
0.055 145 74.64 0
468.873 468.873 1
0.059 146 78.969 0
501.129 501.129 1
0.062 147 83.657 0
536.078 536.078 1
0.066 148 88.738 0
573.994 573.994 1
0.07 149 94.252 0
615.234 615.234 1
0.074