Case #1 Palisades CEDM created on Thu Sep 24 11:40:01 2020 OD

[inches]

t [inches]

Weld Width

[inches]

Inlay 1 =

Yes Inlay Thicknes s [inches]

a_0inche s]

2c_0inch es]

Temp Pressure Axial Bending 200 0

0.3575 0

0 a/t WRS 0

Results Time Units:

Week Flaw Size Units:

inches Time @

a/t = 0.75 Time at Leakage Leakage Size (ID length)

Time at Rupture Rupture Size (ID Length) 105 Weeks 127 Weeks 0.9 inches N/A Calculatio n

Stopped at 2c_OD

= 7.2 inches Time

[Week]

a [mm]

c(ID) [mm]

c(OD)

[mm]

Ka Kc(ID)

Kc(OD) a/t 2c(ID)/a 2c(OD)/C rownWidt h

0 0

32.977 17.156 0

0.1 0

1 0

32.977 17.156 0

0.103 0

2 0

33.441 17.71 0

0.107 0

3 0

33.901 18.272 0

0.11 0

4 0

34.359 18.842 0

0.114 0

5 0

34.812 19.419 0

0.117 0

6 0

35.262 20.002 0

0.121 0

7 0

35.707 20.592 0

0.125 0

8 0

36.147 21.186 0

0.128 0

9 0

36.582 21.786 0

0.132 0

10 0

37.011 22.39 0

0.136 0

11 0

37.435 22.999 0

0.14 0

12 0

37.853 23.61 0

0.144 0

13 0

38.265 24.225 0

0.149 0

14 0

38.67 24.842 0

0.153 0

15 0

39.069 25.461 0

0.157 0

16 0

39.462 26.082 0

0.161 0

17 0

39.848 26.704 0

0.166 0

18 0

40.228 27.327 0

0.17 0

19 0

40.601 27.951 0

0.175 0

20 0

40.968 28.574 0

0.179 0

21 0

41.329 29.197 0

0.184 0

22 0

41.683 29.819 0

0.189 0

23 0

42.031 30.44 0

0.194 0

24 0

42.373 31.061 0

0.198 0

25 0

42.71 31.679 0

0.203 0

26 0

43.041 32.296 0

0.208 0

Proprietary info is highlighted

27 0

43.366 32.912 0

0.213 0

28 0

43.687 33.525 0

0.218 0

29 0

44.002 34.135 0

0.223 0

30 0

44.313 34.744 0

0.229 0

31 0

44.62 35.349 0

0.234 0

32 0

44.923 35.953 0

0.239 0

33 0

45.221 36.553 0

0.244 0

34 0

45.516 37.15 0

0.25 0

35 0

45.808 37.745 0

0.255 0

36 0

46.097 38.337 0

0.261 0

37 0

46.383 38.925 0

0.266 0

38 0

46.666 39.511 0

0.272 0

39 0

46.947 40.093 0

0.277 0

40 0

47.226 40.673 0

0.283 0

41 0

47.503 41.249 0

0.289 0

42 0

47.778 41.823 0

0.294 0

43 0

48.052 42.393 0

0.3 0

44 0

48.325 42.961 0

0.306 0

45 0

48.597 43.525 0

0.312 0

46 0

48.868 44.087 0

0.318 0

47 0

49.138 44.645 0

0.324 0

48 0

49.408 45.201 0

0.33 0

49 0

49.678 45.754 0

0.336 0

50 0

49.947 46.304 0

0.342 0

51 0

50.217 46.852 0

0.348 0

52 0

50.487 47.397 0

0.355 0

53 0

50.757 47.939 0

0.361 0

54 0

51.027 48.479 0

0.367 0

55 0

51.298 49.016 0

0.374 0

56 0

51.569 49.55 0

0.38 0

57 0

51.842 50.082 0

0.386 0

58 0

52.115 50.612 0

0.393 0

59 0

52.389 51.139 0

0.4 0

60 0

52.663 51.663 0

0.406 0

61 0

52.939 52.185 0

0.413 0

62 0

53.216 52.705 0

0.42 0

63 0

53.495 53.222 0

0.426 0

64 0

53.774 53.737 0

0.433 0

65 0

54.055 54.248 0

0.44 0

66 0

54.337 54.758 0

0.447 0

67 0

54.62 55.264 0

0.454 0

68 0

54.905 55.767 0

0.461 0

69 0

55.191 56.268 0

0.468 0

70 0

55.479 56.765 0

0.475 0

71 0

55.768 57.26 0

0.482 0

72 0

56.058 57.75 0

0.489 0

73 0

56.351 58.238 0

0.497 0

74 0

56.644 58.721 0

0.504 0

75 0

56.939 59.2 0

0.511 0

76 0

57.236 59.675 0

0.519 0

77 0

57.534 60.145 0

0.526 0

78 0

57.833 60.61 0

0.534 0

79 0

58.134 61.07 0

0.541 0

80 0

58.437 61.524 0

0.549 0

81 0

58.74 61.972 0

0.557 0

82 0

59.045 62.413 0

0.564 0

83 0

59.352 62.847 0

0.572 0

84 0

59.66 63.273 0

0.58 0

85 0

59.969 63.69 0

0.588 0

86 0

60.279 64.099 0

0.596 0

87 0

60.591 64.498 0

0.604 0

88 0

60.903 64.886 0

0.612 0

89 0

61.216 65.263 0

0.62 0

90 0

61.531 65.627 0

0.628 0

91 0

61.846 65.978 0

0.636 0

92 0

62.161 66.314 0

0.645 0

93 0

62.478 66.635 0

0.653 0

94 0

62.795 66.939 0

0.662 0

95 0

63.112 67.225 0

0.67 0

96 0

63.429 67.491 0

0.679 0

97 0

63.746 67.736 0

0.687 0

98 0

64.063 67.958 0

0.696 0

99 0

64.379 68.156 0

0.704 0

100 0

64.695 68.326 0

0.713 0

101 0

65.01 68.469 0

0.722 0

102 0

65.324 68.58 0

0.731 0

103 0

65.636 68.658 0

0.74 0

104 0

65.946 68.701 0

0.749 0

105 0

66.255 68.704 0

0.758 0

106 0

66.561 68.667 0

0.767 0

107 0

66.864 68.584 0

0.776 0

108 0

67.163 68.454 0

0.785 0

109 0

67.459 68.272 0

0.795 0

110 0

67.75 68.034 0

0.804 0

111 0

68.037 67.736 0

0.813 0

112 0

68.318 67.374 0

0.823 0

113 0

68.592 66.943 0

0.832 0

114 0

68.86 66.438 0

0.842 0

115 0

69.12 65.853 0

0.851 0

116 0

69.371 65.183 0

0.861 0

117 0

69.613 64.421 0

0.871 0

118 0

69.845 63.562 0

0.88 0

119 0

70.065 62.597 0

0.89 0

120 0

70.272 61.52 0

0.9 0

121 0

70.466 60.324 0

0.91 0

122 0

70.644 58.999 0

0.92 0

123 0

70.806 57.539 0

0.929 0

124 0

70.95 55.935 0

0.939 0

125 0

71.074 54.178 0

0.949 0

126 0

71.177 52.261 0

0.959 0

127 2.885 0

0 0

1 0.001 128 3.143 0

95.94 162.167 1

0.001 129 3.413 0

97.199 168.574 1

0.001 130 3.694 0

98.413 174.701 1

0.001 131 3.988 0

99.586 180.587 1

0.002 132 4.293 0

100.726 186.27 1

0.002 133 4.609 0

101.849 191.834 1

0.002 134 4.936 0

102.971 197.316 1

0.002 135 5.273 0

104.095 202.735 1

0.002 136 5.622 0

105.22 208.11 1

0.002 137 5.982 0

106.35 213.458 1

0.002 138 6.352 0

107.484 218.796 1

0.002 139 6.734 0

108.626 224.139 1

0.003 140 7.125 0

109.809 228.505 1

0.003 141 7.52 0

111.076 230.761 1

0.003 142 7.92 0

112.346 233.246 1

0.003

143 8.326 0

113.621 235.942 1

0.003 144 8.738 0

114.904 238.837 1

0.003 145 9.156 0

116.197 241.921 1

0.004 146 9.582 0

117.501 245.186 1

0.004 147 10.014 0

118.82 248.626 1

0.004 148 10.437 0

121.954 243.983 1

0.004 149 10.849 0

125.224 238.919 1

0.004 150 11.252 0

128.355 234.722 1

0.004 151 11.648 0

131.383 231.239 1

0.005 152 12.038 0

134.334 228.354 1

0.005 153 12.424 0

137.23 225.98 1

0.005 154 12.805 0

140.089 224.045 1

0.005 155 13.183 0

142.926 222.495 1

0.005 156 13.559 0

145.751 221.283 1

0.005 157 13.933 0

148.575 220.375 1

0.005 158 14.305 0

151.407 219.739 1

0.006 159 14.677 0

154.254 219.353 1

0.006 160 15.048 0

157.123 219.194 1

0.006 161 15.42 0

160.02 219.248 1

0.006 162 15.792 0

162.95 219.499 1

0.006 163 16.165 0

165.919 219.937 1

0.006 164 16.539 0

168.932 220.551 1

0.006 165 16.915 0

171.992 221.333 1

0.007 166 17.293 0

175.105 222.278 1

0.007 167 17.673 0

178.275 223.38 1

0.007 168 18.055 0

181.549 224.501 1

0.007 169 18.44 0

184.887 225.78 1

0.007 170 18.828 0

188.288 227.228 1

0.007 171 19.219 0

191.758 228.843 1

0.008 172 19.614 0

195.301 230.621 1

0.008 173 20.013 0

198.92 232.559 1

0.008 174 20.416 0

202.621 234.657 1

0.008 175 20.824 0

206.409 236.914 1

0.008 176 22.219 0

215.366 215.366 1

0.009 177 22.59 0

219.184 219.184 1

0.009 178 22.97 0

223.113 223.113 1

0.009 179 23.358 0

227.158 227.158 1

0.009 180 23.754 0

231.325 231.325 1

0.009 181 24.159 0

235.617 235.617 1

0.009 182 24.574 0

240.04 240.04 1

0.01 183 24.998 0

244.599 244.599 1

0.01 184 25.431 0

249.3 249.3 1

0.01 185 25.875 0

254.149 254.149 1

0.01 186 26.33 0

259.152 259.152 1

0.01 187 26.795 0

264.316 264.316 1

0.011 188 27.272 0

269.647 269.647 1

0.011 189 27.76 0

275.152 275.152 1

0.011 190 28.261 0

280.839 280.839 1

0.011 191 28.774 0

286.716 286.716 1

0.011 192 29.3 0

292.791 292.791 1

0.012 193 29.84 0

299.073 299.073 1

0.012 194 30.393 0

305.57 305.57 1

0.012 195 30.961 0

312.292 312.292 1

0.012 196 31.545 0

319.249 319.249 1

0.012 197 32.144 0

326.452 326.452 1

0.013 198 32.76 0

333.911 333.911 1

0.013 199 33.392 0

341.639 341.639 1

0.013 200 34.042 0

349.646 349.646 1

0.013

201 34.711 0

357.946 357.946 1

0.014 202 35.399 0

366.552 366.552 1

0.014 203 36.107 0

375.478 375.478 1

0.014 204 36.835 0

384.738 384.738 1

0.014 205 37.585 0

394.347 394.347 1

0.015 206 38.358 0

404.321 404.321 1

0.015 207 39.154 0

414.678 414.678 1

0.015 208 39.975 0

425.434 425.434 1

0.016 209 40.822 0

436.607 436.607 1

0.016 210 41.695 0

448.217 448.217 1

0.016 211 42.596 0

460.283 460.283 1

0.017 212 43.526 0

472.826 472.826 1

0.017 213 44.487 0

485.867 485.867 1

0.017 214 45.479 0

499.428 499.428 1

0.018 215 46.505 0

513.533 513.533 1

0.018 216 47.565 0

528.205 528.205 1

0.019 217 48.661 0

543.47 543.47 1

0.019 218 49.796 0

559.353 559.353 1

0.02 219 50.97 0

575.881 575.881 1

0.02 220 52.185 0

593.081 593.081 1

0.021 221 53.444 0

610.981 610.981 1

0.021 222 54.748 0

629.612 629.612 1

0.022 223 56.099 0

649.002 649.002 1

0.022 224 57.5 0

669.182 669.182 1

0.023 225 58.953 0

690.185 690.185 1

0.023 226 60.459 0

712.042 712.042 1

0.024 227 62.023 0

734.788 734.788 1

0.024 228 63.646 0

758.456 758.456 1

0.025 229 65.331 0

783.083 783.083 1

0.026 230 67.081 0

808.705 808.705 1

0.026 231 68.899 0

835.36 835.36 1

0.027 232 70.787 0

863.089 863.089 1

0.028 233 72.75 0

891.935 891.935 1

0.029 234 74.79 0

921.943 921.943 1

0.029 235 76.912 0

953.162 953.162 1

0.03 236 79.118 0

985.647 985.647 1

0.031 237 81.414 0 1019.458 1019.458 1

0.032 238 83.802 0 1054.663 1054.663 1

0.033 239 86.288 0

1091.34 1091.34 1

0.034 240 88.875 0 1129.577 1129.577 1

0.035 241 91.571 0 1169.481 1169.481 1

0.036