Case #1 Palisades CEDM 0.5 weld width created on Thu Sep 24 12:03:08 2020 OD

[inches]

t [inches]

Weld Width

[inches]

Inlay 1 =

Yes Inlay Thicknes s [inches]

a_0inche s]

2c_0inch es]

Temp Pressure Axial Bending 0.5 0

0.3575 0

0 a/t WRS 0

Results Time Units:

Month Flaw Size Units:

inches Time @

a/t = 0.75 Time at Leakage Leakage Size (ID length)

Time at Rupture Rupture Size (ID Length) 27 Months 36 Months 0.5 inches N/A Calculatio n

Stopped at 2c_OD

= 0.9 inches Time

[Month]

a [mm]

c(ID) [mm]

c(OD)

[mm]

Ka Kc(ID)

Kc(OD) a/t 2c(ID)/a 2c(OD)/C rownWidt h

0 0

32.977 17.156 0

0.1 0

1 0

32.977 17.156 0

0.114 0

2 0

34.898 19.539 0

0.13 0

3 0

36.749 22.045 0

0.147 0

4 0

38.507 24.635 0

0.165 0

5 0

40.155 27.273 0

0.185 0

6 0

41.689 29.925 0

0.205 0

7 0

43.116 32.564 0

0.227 0

8 0

44.449 35.17 0

0.249 0

9 0

45.706 37.728 0

0.273 0

10 0

46.908 40.232 0

0.297 0

11 0

48.075 42.679 0

0.322 0

12 0

49.222 45.07 0

0.348 0

13 0

50.364 47.406 0

0.375 0

14 0

51.512 49.691 0

0.403 0

15 0

52.343 51.866 0

0.432 0

16 0

52.658 53.679 0

0.46 0

17 0

52.882 55.087 0

0.489 0

18 0

53.008 56.087 0

0.518 0

19 0

53.015 56.719 0

0.547 0

20 0

52.872 57.094 0

0.576 0

21 0

52.546 57.425 0

0.605 0

22 0

52.003 58.078 0

0.633 0

23 0

51.215 59.617 0

0.661 0

24 0

50.17 62.844 0

0.687 0

25 0

48.871 68.804 0

0.713 0

Proprietary info is highlighted

26 0

48.075 73.101 0

0.738 0

27 0

47.848 73.663 0

0.763 0

28 0

47.619 74.209 0

0.788 0

29 0

47.391 74.74 0

0.813 0

30 0

47.165 75.254 0

0.838 0

31 0

46.944 75.754 0

0.862 0

32 0

46.728 76.238 0

0.886 0

33 0

46.52 76.707 0

0.91 0

34 0

46.321 77.159 0

0.934 0

35 0

46.131 77.596 0

0.958 0

36 1.588 0

0 0

1 0.137 37 2.218 0

65.722 102.45 1

0.192 38 2.946 0

69.452 114.799 1

0.255 39 3.744 0

72.435 123.661 1

0.324 40 4.607 0

75.444 131.437 1

0.399 41 5.476 0

78.624 132.319 1

0.474 42 6.364 0

81.907 134.58 1

0.551 43 7.214 0

87.882 130 1

0.624 44 8.044 0

93.883 127.392 1

0.696 45 8.881 0

99.515 128.348 1

0.768 46 9.738 0

105.218 130.91 1

0.843 47 10.623 0

111.212 134.229 1

0.919 48 11.541 0

117.575 138.245 1

0.999 49 11.558 0

124.383 142.946 1

1