Case #1 Palisades created on Thu Sep 24 11:57:56 2020 OD

[inches]

t [inches]

Weld Width

[inches]

Inlay 1 =

Yes Inlay Thicknes s [inches]

a_0inche s]

2c_0inch es]

Temp Pressure Axial Bending 0.1 0

0.3575 0

0 a/t WRS 0

Results Time Units:

Month Flaw Size Units: inches Time @

a/t = 0.75 Time at Leakage Leakage Size (ID length)

Time at Rupture Rupture Size (ID Length) 65 Months 79 Months 0.1 inches N/A Calculatio n

Stopped at 2c_OD

= 0.5 inches Time

[Month]

a [mm]

c(ID) [mm]

c(OD)

[mm]

Ka Kc(ID)

Kc(OD) a/t 2c(ID)/a 2c(OD)/C rownWidt h

0 0

32.977 17.156 0

0.1 0

1 0

32.977 17.156 0

0.114 0

2 0

24.953 26.747 0

0.123 0

3 0

24.998 27.797 0

0.132 0

4 0

25.045 28.892 0

0.141 0

5 0

25.088 29.922 0

0.15 0

6 0

25.01 29.905 0

0.159 0

7 0

24.905 29.857 0

0.168 0

8 0

24.78 29.785 0

0.177 0

9 0

24.64 29.695 0

0.186 0

10 0

24.488 29.59 0

0.194 0

11 0

24.328 29.476 0

0.203 0

12 0

24.162 29.354 0

0.211 0

13 0

23.993 29.227 0

0.22 0

14 0

23.822 29.098 0

0.228 0

15 0

23.651 28.967 0

0.236 0

16 0

23.48 28.835 0

0.244 0

17 0

23.31 28.704 0

0.252 0

18 0

23.142 28.575 0

0.259 0

19 0

22.975 28.447 0

0.267 0

20 0

22.812 28.321 0

0.275 0

21 0

22.651 28.198 0

0.282 0

22 0

22.622 28.238 0

0.29 0

23 0

22.866 28.622 0

0.297 0

24 0

23.111 29.011 0

0.305 0

25 0

23.356 29.404 0

0.313 0

26 0

23.601 29.802 0

0.321 0

27 0

23.846 30.205 0

0.329 0

28 0

24.091 30.614 0

0.337 0

29 0

24.335 31.027 0

0.346 0

30 0

24.579 31.446 0

0.355 0

31 0

24.823 31.87 0

0.363 0

32 0

25.066 32.299 0

0.372 0

Proprietary info is highlighted

33 0

25.309 32.734 0

0.382 0

34 0

25.551 33.174 0

0.391 0

35 0

25.792 33.621 0

0.4 0

36 0

26.033 34.073 0

0.41 0

37 0

26.273 34.531 0

0.42 0

38 0

26.512 34.996 0

0.43 0

39 0

26.75 35.466 0

0.44 0

40 0

26.988 35.943 0

0.45 0

41 0

27.224 36.427 0

0.461 0

42 0

27.46 36.918 0

0.471 0

43 0

27.695 37.415 0

0.482 0

44 0

27.929 37.92 0

0.493 0

45 0

28.162 38.432 0

0.504 0

46 0

28.394 38.951 0

0.515 0

47 0

28.625 39.478 0

0.526 0

48 0

28.856 40.012 0

0.538 0

49 0

29.085 40.555 0

0.55 0

50 0

29.314 41.106 0

0.561 0

51 0

29.542 41.665 0

0.573 0

52 0

29.769 42.232 0

0.585 0

53 0

29.996 42.809 0

0.598 0

54 0

30.222 43.394 0

0.61 0

55 0

30.448 43.988 0

0.623 0

56 0

30.673 44.591 0

0.635 0

57 0

30.898 45.204 0

0.648 0

58 0

31.123 45.826 0

0.661 0

59 0

31.348 46.458 0

0.675 0

60 0

31.573 47.099 0

0.688 0

61 0

31.798 47.751 0

0.702 0

62 0

32.023 48.412 0

0.715 0

63 0

32.249 49.084 0

0.729 0

64 0

32.475 49.766 0

0.743 0

65 0

32.703 50.459 0

0.757 0

66 0

32.931 51.162 0

0.771 0

67 0

33.161 51.875 0

0.786 0

68 0

33.392 52.599 0

0.8 0

69 0

33.625 53.333 0

0.815 0

70 0

33.86 54.078 0

0.83 0

71 0

34.097 54.834 0

0.845 0

72 0

34.336 55.6 0

0.861 0

73 0

34.578 56.377 0

0.876 0

74 0

34.823 57.164 0

0.892 0

75 0

35.072 57.961 0

0.907 0

76 0

35.324 58.768 0

0.923 0

77 0

35.58 59.585 0

0.939 0

78 0

35.841 60.412 0

0.956 0

79 0.318 0

0 0

1 0.049 80 0.501 0

26.49 41.293 1

0.077 81 0.724 0

28.084 47.187 1

0.112 82 0.974 0

29.314 51.036 1

0.15 83 1.221 0

30.571 50.76 1

0.189 84 1.451 0

32.857 48.15 1

0.224 85 1.665 0

35.356 45.828 1

0.257 86 1.875 0

37.54 45.234 1

0.289 87 2.087 0

39.615 45.5 1

0.322 88 2.304 0

41.66 46.282 1

0.356 89 2.529 0

43.716 47.416 1

0.39 90 2.763 0

45.804 48.81 1

0.426 91 3.121 0

48.478 48.478 1

0.482 92 3.367 0

50.615 50.615 1

0.52 93 3.629 0

52.835 52.835 1

0.56

94 3.907 0

55.143 55.143 1

0.603 95 4.202 0

57.544 57.544 1

0.649 96 4.514 0

60.046 60.046 1

0.697 97 4.845 0

62.655 62.655 1

0.748 98 5.196 0

65.381 65.381 1

0.802 99 5.567 0

68.233 68.233 1

0.859 100 5.961 0

71.222 71.222 1

0.92 101 6.377 0

74.361 74.361 1

0.984 102 6.478 0

77.664 77.664 1

1