ML24113A157
| ML24113A157 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 04/18/2024 |
| From: | NRC/OCIO |
| To: | |
| References | |
| NRC-2020-000324, FOIA | |
| Download: ML24113A157 (1) | |
Text
Case #2 Palisades created on Thu Sep 24 14:39:07 2020 OD
[inches]
t [inches]
Weld Width
[inches]
Inlay 1 =
Yes Inlay Thicknes s [inches]
a_0inche s]
2c_0inch es]
Temp Pressure Axial Bending 200 0
0.3575 0
0 a/t WRS 0
Results Time Units:
Month Flaw Size Units: inches Time @
a/t = 0.75 Time at Leakage Leakage Size (ID length)
Time at Rupture Rupture Size (ID Length) 25 Months 31 Months 0.9 inches N/A Calculatio n
Stopped at 2c_OD
= 8.0 inches Time
[Month]
a [mm]
c(ID) [mm]
c(OD)
[mm]
Ka Kc(ID)
Kc(OD) a/t 2c(ID)/a 2c(OD)/C rownWidt h
0 0
32.977 17.156 0
0.1 0
1 0
32.977 17.156 0
0.114 0
2 0
34.898 19.539 0
0.13 0
3 0
36.749 22.045 0
0.147 0
4 0
38.507 24.635 0
0.165 0
5 0
40.155 27.273 0
0.185 0
6 0
41.689 29.925 0
0.205 0
7 0
43.116 32.564 0
0.227 0
8 0
44.449 35.17 0
0.249 0
9 0
45.706 37.728 0
0.273 0
10 0
46.908 40.232 0
0.297 0
11 0
48.075 42.679 0
0.322 0
12 0
49.222 45.07 0
0.348 0
13 0
50.364 47.406 0
0.375 0
14 0
51.512 49.691 0
0.403 0
15 0
52.674 51.928 0
0.432 0
16 0
53.857 54.116 0
0.462 0
17 0
55.064 56.251 0
0.492 0
18 0
56.298 58.327 0
0.524 0
19 0
57.56 60.326 0
0.556 0
20 0
58.849 62.225 0
0.59 0
21 0
60.162 63.988 0
0.624 0
22 0
61.496 65.564 0
0.66 0
23 0
62.845 66.881 0
0.696 0
24 0
64.198 67.84 0
0.734 0
25 0
65.541 68.309 0
0.773 0
26 0
66.854 68.107 0
0.812 0
27 0
68.107 66.991 0
0.853 0
28 0
69.258 64.636 0
0.895 0
29 0
70.249 60.614 0
0.937 0
30 0
70.999 54.381 0
0.981 0
31 2.917 0
0 0
1 0.001 32 4.05 0
96.472 163.908 1
0.002 33 5.399 0
101.465 189.073 1
0.002 34 6.953 0
106.282 212.463 1
0.003 Proprietary info is highlighted
35 8.696 0
111.269 233.69 1
0.003 36 10.546 0
116.836 245.451 1
0.004 37 12.379 0
126.242 243.607 1
0.005 38 14.052 0
139.859 225.745 1
0.006 39 15.662 0
152.244 218.839 1
0.006 40 17.263 0
164.655 217.694 1
0.007 41 18.887 0
177.674 220.397 1
0.007 42 20.559 0
191.826 225.714 1
0.008 43 23.076 0
211.941 211.941 1
0.009 44 24.771 0
228.299 228.299 1
0.01 45 26.633 0
246.787 246.787 1
0.01 46 28.688 0
267.789 267.789 1
0.011 47 30.964 0
291.767 291.767 1
0.012 48 33.499 0
319.281 319.281 1
0.013 49 36.338 0
351.012 351.012 1
0.014 50 39.534 0
387.782 387.782 1
0.016 51 43.152 0
430.583 430.583 1
0.017 52 47.272 0
480.603 480.603 1
0.019 53 51.993 0
539.246 539.246 1
0.02 54 57.432 0
608.146 608.146 1
0.023 55 63.734 0
689.169 689.169 1
0.025 56 71.07 0
784.414 784.414 1
0.028 57 79.647 0
896.256 896.256 1
0.031 58 89.714 0 1027.566 1027.566 1
0.035 59 101.576 0 1182.428 1182.428 1
0.04