Case #1 Near weld created on Mon Sep 28 17:46:14 2020 OD
[inches]
t [inches]
Weld Width
[inches]
Inlay 1 =
Yes Inlay Thicknes s [inches]
a_0inche s]
2c_0inch es]
Temp Pressure Axial Bending 100 0
0.3575 0
0 a/t WRS 0
Results Time Units:
Month Flaw Size Units:
inches Time @
a/t = 0.75 Time at Leakage Leakage Size (ID length)
Time at Rupture Rupture Size (ID Length) 26 Months 32 Months 0.9 inches N/A Calculatio n
Stopped at 2c_OD
= 7.6 inches Time
[Month]
a [mm]
c(ID)
[mm]
c(OD)
[mm]
Ka Kc(ID)
Kc(OD) a/t 2c(ID)/a 2c(OD)/C rownWidt h
0 0
33.112 17.185 0
0.1 0
1 0
33.112 17.185 0
0.114 0
2 0
35.067 19.591 0
0.13 0
3 0
36.955 22.122 0
0.147 0
4 0
38.73 24.742 0
0.166 0
5 0
40.377 27.409 0
0.185 0
6 0
41.896 30.089 0
0.206 0
7 0
43.293 32.752 0
0.228 0
8 0
44.584 35.376 0
0.25 0
9 0
45.787 37.948 0
0.274 0
10 0
46.915 40.458 0
0.298 0
11 0
47.992 42.903 0
0.323 0
12 0
49.036 45.282 0
0.349 0
13 0
50.06 47.598 0
0.376 0
14 0
51.073 49.853 0
0.404 0
15 0
52.052 52.048 0
0.432 0
16 0
53.016 54.181 0
0.461 0
17 0
53.972 56.246 0
0.491 0
Proprietary info is highlighted
18 0
54.922 58.234 0
0.521 0
19 0
55.799 60.129 0
0.552 0
20 0
56.546 61.903 0
0.584 0
21 0
57.21 63.517 0
0.616 0
22 0
57.797 64.925 0
0.649 0
23 0
58.379 66.066 0
0.682 0
24 0
58.95 66.867 0
0.715 0
25 0
59.468 67.228 0
0.749 0
26 0
59.907 67.022 0
0.784 0
27 0
60.127 66.084 0
0.818 0
28 0
60.132 64.211 0
0.853 0
29 0
59.913 61.143 0
0.887 0
30 0
59.486 56.551 0
0.921 0
31 0
58.963 50.01 0
0.954 0
32 2.974 0
0 0
1 0.002 33 3.954 0
84.972 145.7 1
0.003 34 5.097 0
88.781 165.238 1
0.004 35 6.397 0
92.448 183.372 1
0.005 36 7.851 0
96.157 201.115 1
0.006 37 9.401 0
100.217 212.061 1
0.007 38 11.041 0
104.466 222.09 1
0.009 39 12.59 0
113.568 211.909 1
0.01 40 14.032 0
123.62 199.811 1
0.011 41 15.427 0
132.984 194.321 1
0.012 42 16.807 0
142.325 192.715 1
0.013 43 18.197 0
151.989 193.812 1
0.014 44 19.613 0
162.295 196.785 1
0.015 45 21.072 0
173.352 201.662 1
0.017 46 23.367 0
189.337 189.337 1
0.018 47 24.827 0
201.88 201.88 1
0.019 48 26.411 0
215.824 215.824 1
0.021 49 28.134 0
231.384 231.384 1
0.022 50 30.014 0
248.812 248.812 1
0.024 51 32.074 0
268.408 268.408 1
0.025 52 34.339 0
290.524 290.524 1
0.027 53 36.839 0
315.576 315.576 1
0.029 54 39.611 0
344.055 344.055 1
0.031 55 42.697 0
376.538 376.538 1
0.033 56 46.147 0
413.696 413.696 1
0.036 57 50.023 0
456.307 456.307 1
0.039 58 54.394 0
505.261 505.261 1
0.043 59 59.346 0
561.561 561.561 1
0.047 60 64.977 0
626.321 626.321 1
0.051 61 71.404 0
700.773 700.773 1
0.056 62 78.761 0
786.294 786.294 1
0.062 63 87.206 0
884.534 884.534 1
0.068 64 96.932 0
997.727 997.727 1
0.076