Case #0 Expanded created on Mon Sep 28 17:46:13 2020 OD

[inches]

t [inches]

Weld Width

[inches]

Inlay 1 =

Yes Inlay Thicknes s [inches]

a_0inche s]

2c_0inch es]

Temp Pressure Axial Bending 100 0

0.3575 0

0 a/t WRS 0

Results Time Units:

Month Flaw Size Units:

inches Time @

a/t = 0.75 Time at Leakage Leakage Size (ID length)

Time at Rupture Rupture Size (ID Length) 75 Months 89 Months 0.9 inches N/A Calculatio n

Stopped at 2c_OD

= 7.4 inches Time

[Month]

a [mm]

c(ID)

[mm]

c(OD)

[mm]

Ka Kc(ID)

Kc(OD) a/t 2c(ID)/a 2c(OD)/C rownWidt h

0 0

16.397 8.531 0

0.1 0

1 0

16.397 8.531 0

0.104 0

2 0

16.65 8.846 0

0.107 0

3 0

16.903 9.172 0

0.111 0

4 0

17.157 9.508 0

0.116 0

5 0

17.411 9.853 0

0.12 0

6 0

17.664 10.207 0

0.124 0

7 0

17.916 10.568 0

0.129 0

8 0

18.167 10.937 0

0.133 0

9 0

18.415 11.312 0

0.138 0

10 0

18.661 11.693 0

0.143 0

11 0

18.904 12.08 0

0.148 0

12 0

19.143 12.471 0

0.154 0

13 0

19.379 12.866 0

0.159 0

14 0

19.611 13.264 0

0.165 0

15 0

19.84 13.666 0

0.17 0

16 0

20.063 14.069 0

0.176 0

17 0

20.283 14.473 0

0.182 0

18 0

20.499 14.879 0

0.188 0

19 0

20.71 15.284 0

0.195 0

20 0

20.918 15.69 0

0.201 0

21 0

21.121 16.095 0

0.207 0

22 0

21.321 16.499 0

0.214 0

23 0

21.518 16.902 0

0.221 0

24 0

21.712 17.303 0

0.228 0

25 0

21.903 17.703 0

0.235 0

26 0

22.091 18.101 0

0.242 0

Proprietary info is highlighted

27 0

22.277 18.496 0

0.249 0

28 0

22.461 18.889 0

0.256 0

29 0

22.644 19.28 0

0.264 0

30 0

22.826 19.668 0

0.271 0

31 0

23.006 20.054 0

0.279 0

32 0

23.186 20.438 0

0.287 0

33 0

23.366 20.819 0

0.295 0

34 0

23.546 21.198 0

0.303 0

35 0

23.726 21.574 0

0.311 0

36 0

23.906 21.948 0

0.319 0

37 0

24.087 22.32 0

0.327 0

38 0

24.269 22.69 0

0.336 0

39 0

24.451 23.058 0

0.344 0

40 0

24.635 23.424 0

0.353 0

41 0

24.821 23.789 0

0.362 0

42 0

25.008 24.151 0

0.371 0

43 0

25.196 24.512 0

0.38 0

44 0

25.387 24.871 0

0.389 0

45 0

25.579 25.229 0

0.399 0

46 0

25.773 25.585 0

0.408 0

47 0

25.97 25.939 0

0.418 0

48 0

26.175 26.292 0

0.427 0

49 0

26.384 26.644 0

0.437 0

50 0

26.598 26.994 0

0.447 0

51 0

26.816 27.342 0

0.457 0

52 0

27.038 27.689 0

0.468 0

53 0

27.264 28.034 0

0.478 0

54 0

27.494 28.376 0

0.489 0

55 0

27.728 28.717 0

0.5 0

56 0

27.965 29.054 0

0.51 0

57 0

28.207 29.388 0

0.522 0

58 0

28.452 29.719 0

0.533 0

59 0

28.702 30.045 0

0.544 0

60 0

28.955 30.366 0

0.556 0

61 0

29.212 30.682 0

0.568 0

62 0

29.472 30.99 0

0.579 0

63 0

29.737 31.291 0

0.592 0

64 0

30.005 31.582 0

0.604 0

65 0

30.276 31.863 0

0.616 0

66 0

30.551 32.131 0

0.629 0

67 0

30.829 32.385 0

0.642 0

68 0

31.11 32.623 0

0.655 0

69 0

31.395 32.843 0

0.668 0

70 0

31.681 33.041 0

0.682 0

71 0

31.971 33.214 0

0.695 0

72 0

32.262 33.36 0

0.709 0

73 0

32.554 33.474 0

0.723 0

74 0

32.848 33.552 0

0.737 0

75 0

33.143 33.589 0

0.752 0

76 0

33.437 33.58 0

0.766 0

77 0

33.73 33.517 0

0.781 0

78 0

34.021 33.395 0

0.796 0

79 0

34.309 33.205 0

0.811 0

80 0

34.593 32.939 0

0.827 0

81 0

34.871 32.588 0

0.843 0

82 0

35.142 32.14 0

0.858 0

83 0

35.403 31.584 0

0.874 0

84 0

35.652 30.908 0

0.891 0

85 0

35.887 30.099 0

0.907 0

86 0

36.105 29.144 0

0.923 0

87 0

36.303 28.028 0

0.94 0

88 0

36.476 26.741 0

0.957 0

89 2.793 0

0 0

1 0.002 90 3.272 0

49.737 82.822 1

0.003 91 3.796 0

50.916 88.707 1

0.003 92 4.362 0

52.027 94.172 1

0.003 93 4.968 0

53.077 99.322 1

0.004 94 5.613 0

54.124 104.339 1

0.004 95 6.297 0

55.181 109.298 1

0.005 96 7.021 0

56.251 114.253 1

0.006 97 7.762 0

57.428 116.548 1

0.006 98 8.523 0

58.627 118.874 1

0.007 99 9.305 0

59.842 121.571 1

0.007 100 10.109 0

61.16 124.247 1

0.008 101 10.868 0

64.386 118.792 1

0.009 102 11.598 0

67.328 115.057 1

0.009 103 12.308 0

70.115 112.498 1

0.01 104 13.004 0

72.824 110.795 1

0.01 105 13.691 0

75.506 109.748 1

0.011 106 14.375 0

78.196 109.227 1

0.011 107 15.058 0

80.923 109.144 1

0.012 108 15.743 0

83.708 109.439 1

0.012 109 16.433 0

86.569 110.069 1

0.013 110 17.131 0

89.524 111.006 1

0.013 111 17.838 0

92.587 112.23 1

0.014 112 18.557 0

95.781 113.704 1

0.015 113 19.289 0

99.14 115.368 1

0.015 114 20.037 0

102.643 117.336 1

0.016 115 21.647 0

108.659 108.659 1

0.017 116 22.356 0

112.359 112.359 1

0.018 117 23.095 0

116.276 116.276 1

0.018 118 23.868 0

120.428 120.428 1

0.019 119 24.677 0

124.832 124.832 1

0.019 120 25.523 0

129.511 129.511 1

0.02 121 26.41 0

134.487 134.487 1

0.021 122 27.341 0

139.786 139.786 1

0.021 123 28.318 0

145.435 145.435 1

0.022 124 29.346 0

151.466 151.466 1

0.023 125 30.428 0

157.913 157.913 1

0.024 126 31.569 0

164.812 164.812 1

0.025 127 32.772 0

172.204 172.204 1

0.026 128 34.043 0

180.135 180.135 1

0.027 129 35.388 0

188.654 188.654 1

0.028 130 36.813 0

197.816 197.816 1

0.029 131 38.325 0

207.68 207.68 1

0.03 132 39.931 0

218.313 218.313 1

0.031 133 41.64 0

229.786 229.786 1

0.033 134 43.46 0

242.177 242.177 1

0.034 135 45.402 0

255.573 255.573 1

0.036 136 47.477 0

270.066 270.066 1

0.037 137 49.697 0

285.755 285.755 1

0.039 138 52.077 0

302.749 302.749 1

0.041 139 54.63 0

321.163 321.163 1

0.043 140 57.374 0

341.119 341.119 1

0.045

141 60.325 0

362.748 362.748 1

0.047 142 63.505 0

386.187 386.187 1

0.05 143 66.935 0

411.581 411.581 1

0.052 144 70.638 0

439.086 439.086 1

0.055 145 74.64 0

468.873 468.873 1

0.059 146 78.969 0

501.129 501.129 1

0.062 147 83.657 0

536.078 536.078 1

0.066 148 88.738 0

573.994 573.994 1

0.07 149 94.252 0

615.234 615.234 1

0.074