The U.S. Nuclear Regulatory Commission Sponsored Projects on Chloride-Induced Stress Corrosion Cracking
ML24107B036
Person / Time
Issue date: 05/31/2024
From: Darrell Dunn
NRC/NMSS/DFM/MSB
To:
References
Download: ML24107B036 (1)


Text

NRC Sponsored Projects on Chloride-Induced Stress Corrosion Cracking Darrell Dunn NRC/NMSS/DFM/MSB

Outline

  • Completed projects - inspection and mitigation
  • Current projects - Chloride-induced stress corrosion cracking (CISCC) risk assessment o CISCC growth rate testing o Probabilistic assessment of CISCC
  • Guidance development o New Regulatory Guide for ASME Section XI code cases applicable to 10 CFR Part 72 licensees and certificate of compliance holders
  • Public outreach o CISCC consequence analysis NEI UFMC May 2024 2

CISCC Testing Observations

  • CISCC growth rates dependent on
  • temperature
  • stress intensity
  • relative humidity
  • nitrate to chloride ratio Nitrate is an effective inhibitor for CISCC PNNL-32455 PNNL-Recommended CISCC Growth Rate Evaluation Test Plan for the NRC Update #1, January 2022 NEI UFMC May 2024 3

Probabilistic Assessment of CISCC SAND2024-01093, Assessing Uncertainty in Modeling Stress Corrosion Cracking January 2024

  • Compared crack growth rate (CGR) models typically used in CISCC
  • Evaluated 3 parameters o Limiting relative humidity for corrosion initiation (RHL) o Salt deposition rate (DD),

o threshold crack tip stress intensity factor (Kth)

DD > Kth > RHL NEI UFMC May 2024 4

ASME N-860

  • Applies only to welded austenitic stainless steel canisters
  • Uses EPRI-3002005371, Susceptibility Assessment Criteria for CISCC of Welded Stainless Steel Canisters for Dry Cask Storage Systems, to set initial inspection population
  • CISCC ranking: ZISFSI = Clstarting + Cladj + AHadj
  • High rank site: ZISFSI 8
  • Low rank site: ZISFSI 7
  • Inspection interval can be increased from 10 to 20 years for low rank sites with no indications CISCC NEI UFMC May 2024 5

Locations and ZISFSI Values 71 operating ISFSI sites with 3755 welded austenitic stainless steel DSS in use as of December 2023 ZISFSI = Clstarting + Cladj + AHadj EPRI-3002005371 ZISFSI ISFSI sites (estimated)

DSSs (estimated) 1-3 60 3,148 4-7 6

295 8-10 5

312 NEI UFMC May 2024 6

Risk Assessment for ZISFSI 3 Sites

  • Atmospheric CISCC has occurred at locations that are less than 1 km from a marine shoreline (NRC Information Notice 201220, ML12319A440)
  • ZISFSI 7
  • Composition of salt deposits at ISFSI sites with ZISFSI 3 are not expected promote CISCC
  • Assuming CISCC could occur, CISCC propagation ZISFSI 3 sites would proceed slowly SAND202306366J, Considerations for Realistic Atmospheric Environments: An Application to Corrosion Testing, R. M.

Katona, A. W. Knight, M. Maguire, C. R. Bryan, and R. F. Schaller.

NEI UFMC May 2024 7

New Regulatory Guide 3.78 Regulatory Guide (RG) 3.78, Acceptable ASME Section XI Inservice Inspection Code Cases for 10 CFR Part 72

  • RG 3.78 will be published for public comment as Draft Guide (DG) 3058
  • Will include ASME Code Case N860, Inspection Requirements and Evaluation Standards for Spent Nuclear Fuel Storage and Transportation Containment SystemsSection XI, Div. 1;Section XI, Div. 2.
  • DG3058 includes alternative inspection intervals of up to 40 years for ZISFSI 3 sites NEI UFMC May 2024 8

Consequence Analysis for CISCC Initial assessment

  • Risk assessment for accidents are bounding for CISCC consequences
  • Site boundary doses are below regulatory limits Current effort
  • GoldSim Monte Carlo simulation software model under development
  • Conduct simulations to understand the importance of input parameters GoldSim CISCC consequence analysis model user interface NEI UFMC May 2024 9

Reports

  • PNNL28643: Dry Storage System Test Facility for Evaluating Canister Inspection Technologies, September 2019, ML19269B757
  • PNNL29774: PNNL-Recommended CISCC Measurement Test Plan for the NRC, April 2020, ML20084K352
  • PNNL30001: Inspection Technology Demonstration on Dry Storage System Test Facility Flaw Sizing Demonstration, September 2020, ML20275A004
  • PNNL28643: Assessment of Cold Spray Technology for Nuclear Power Applications, March 2021, ML21263A107
  • PNNL32455: PNNL-Recommended CISCC Growth Rate Evaluation Test Plan for the NRC Update #1, January 2022
  • PNNL35667: CISCC Testing of 300 Series Stainless Steels Test Results From Concentrated Salts, October 2023 NEI UFMC May 2024 10

NRC Sponsored Projects on Chloride-Induced Stress Corrosion Cracking Darrell Dunn NRC/NMSS/DFM/MSB