Dominion Energy Nuclear Connecticut, Inc.
Millstone Power Station 314 Rope Ferry Road, Waterford, CT 06385 Dominion Energy.com U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 APR 15 2024 DOMINION ENERGY NUCLEAR CONNECTICUT, INC.
MILLSTONE POWER STATION UNIT 3 2023 ANNUAL ENVIRONMENTAL OPERATING REPORT
~
Dominion
~
Energy Serial No.
MPS Lie/LO Docket No.
License No.24-090 RO 50-423 NPF-49 In accordance with Section 5.4.1 of the Environmental Protection Plan (EPP), Appendix B to the Millstone Power Station Unit 3 Operating License, Dominion Energy Nuclear Connecticut, Inc.
hereby submits the Annual Environmental Operating Report (AEOR), describing implementation of the EPP for the previous year. Enclosure 1 transmits information for the period of January 1, 2023, to December 31, 2023.
Should you have any questions regarding this report, please contact Mr. Dean E. Rowe at (860) 444-5292.
Sincerely, L. J. Armstrong Director, Nuclear Station Safety and Licensing
Enclosures:
1 Commitments made in this letter: None.
cc:
U.S. Nuclear Regulatory Commission Region I 475 Allendale Rd., Suite 102 King of Prussia, PA 19406-1415 R. V. Guzman NRC Project Manager Millstone Units 2 and 3 U.S. Nuclear Regulatory Commission One White Flint North, Mail Stop 08 C2 11555 Rockville Pike Rockville, MD 20852-2738 NRC Senior Resident Inspector Millstone Power Station Serial No.24-090 2023 Annual Environmental Operating Report Page 2 of 2
Serial No.24-090 2023 Annual Environmental Operating Report MILLSTONE POWER STATION UNIT 3 2023 ANNUAL ENVIRONMENTAL OPERATING REPORT JANUARY 1, 2023 - DECEMBER 31, 2023 MILLSTONE POWER STATION UNIT 3 DOMINION ENERGY NUCLEAR CONNECTICUT, INC. (DENC)
2023 AEOR Page 1 of 3 2023 Annual Environmental Operating Report (AEOR) 1.
Introduction:
This report covers the period January 1, 2023 through December 31, 2023. During 2023, Millstone Power Station Unit 3 (MPS3) concluded fuel cycle 22 in October 2023: MPS3 underwent a refueling outage from October 20, 2023 to November 30, 2023. Fuel cycle 23 began in November 2023 and is expected to continue until Spring 2025. MPS3 had a forced outage from June 1 to July 3.
As required by the MPS3 Environmental Protection Plan (EPP), Appendix B to the MPS3 Operating License, this AEOR includes:
- summaries and analyses of the results of environmental protection activities,
- a list of EPP non-compliances and the corrective actions taken to remedy them,
- a list of all changes in station design or operation, tests, and experiments which involved a potentially significant unreviewed environmental question, and
- a list of non-routine reports submitted in accordance with subsection 5.4.2.
- 2. Environmental Monitoring Activities:
2.1 Annual National Pollutant Discharge Elimination System (NPDES) Report of Ecological Monitoring (EPP Section 4.2).
Section 10(A) of Millstone Power Stations (MPS) NPDES permit (the Permit), as issued to Dominion Nuclear Connecticut, Inc. (DNC; now Dominion Energy Nuclear Connecticut, DENC) by the Connecticut Department of Environmental Protection (DEP; now the Department of Energy and Environmental Protection, or DEEP) on September 1, 2010, requires, among other things, continuation of biological studies of supplying and receiving waters. These studies include analyses of intertidal and subtidal benthic communities, finfish communities, entrained plankton, lobster populations, and winter flounder populations. Section 10(A)(2) of the Permit requires an annual report of these studies to be sent to the DEEP Commissioner on or before July 31 of each year. The latest report that fulfills these requirements, Annual Report 2022 - Monitoring the Marine Environment of Long Island Sound at Millstone Power Station, Waterford, Connecticut (Annual Report), dated July 2023, presents results from long-term studies, emphasizing those of the latest sampling year. Characteristics of and changes to the biological communities noted in these studies are summarized in the Executive Summary section of the Annual Report, which is attached as part of this report.
2.2 Effluent Water Quality Monitoring:
Several sections of the Permit require monitoring and recording of various water quality parameters at MPS intakes and at multiple monitoring points within the plant, including outfalls of each unit to the effluent quarry, and outfall of the quarry to Long Island Sound. Section 8 of the Permit requires that a monthly report of this monitoring be submitted to the DEEP. The report that fulfills these requirements, the Monthly Discharge Monitoring Report (DMR), includes discharge data from all MPS units. Consistent with prior annual AEOR
2023 AEOR Page 2 of 3 submissions, water flow, temperature, pH, and chlorine data pertaining to MPS3 are summarized in Table 1.
Each monthly DMR identifies NPDES permit exceedances (i.e., events where a parameter value was beyond permitted limits) or exceptions (i.e., events where Permit conditions were not met) for the month. During 2023, there were no exceedances or exceptions at a discharge associated with MPS3.
2.3 NPDES Permit Renewal By way of background, in 2014 MPS established a team, and scheduled milestones, to ensure that a completed permit renewal application was submitted to the DEEP, in accordance with general requirements, prior to the permits expiration in August 2015. The permit renewal application was submitted on February 6, 2015, and the DEEP issued a Notice of Sufficiency on March 6, 2015; therefore, the permit is administratively continued and in effect until its reissuance.
- 3. Environmental Protection Plan (EPP) Non-compliances:
No EPP non-compliances were identified for MPS3 in 2023.
- 4. Environmentally Significant Changes to Station Design or Operation, Tests, and Experiments:
No MPS3 design change records or system operating procedure changes initiated during 2023 included a determination that a significant unreviewed environmental question existed.
- 5. Non-Routine Reports of Environmentally Significant Events:
No non-routine reports were submitted in accordance with subsection 5.4.2 of the EPP.
2023 AEOR Page 3 of 3 Table 1. MPS3 NPDES data summary, Jan 1-Dec 31, 2023. Selected water quality parameters for MPS3(1).
2023 Maximum Discharge Flow (106 gpd)
Discharge pH Range (SU)
Discharge Temp.
Range (oF)
Average Discharge Temp. (oF)
Average Temp.
(oF)
Maximum FAC (ppm)
Maximum TRC (ppm)
Min Max Min Max January 1361.2 7.9 8.1 47.3 68.5 62.1 17.6 0.08 0.03 0.19 February 1231.8 7.9 8.3 57.3 67.5 63.7 18.9 0.06 0.04 0.17 March 1287.6 7.8 8.2 60.1 75.1 66.0 22.3 0.06 0.03 0.16 April 1199.8 7.9 8.1 62.3 83.3 74.8 26.4 0.07 0.04 0.18 May 1349.8 7.9 8.1 56.5 82.3 74.5 19.2 0.06 0.05 0.14 June 909.7 6.9 8.1 56.4 82.7 61.2 0.0 0.10 0.03 0.16 July 1343.6 7.5 8.1 78.2 91.9 86.3 15.3 0.06 0.07 0.15 August 1361.1 7.7 8.1 84.3 92.9 87.2 16.8 0.07 0.06 0.17 September 1361.3 7.9 8.1 82.1 93.6 85.8 15.6 0.06 0.07 0.18 October 219.0 7.3 8.1 61.8 87.1 75.2 11.8 0.05 0.07 0.20 November 1064.5 7.5 8.2 48.4 65.9 58.3 4.3 NA (2) 0.03 NA (2)
December 1360.7 7.9 8.1 47.7 75.0 62.6 14.9 0.05 0.03 0.17 Notes:
(1)
Parameters are measured at MPS3 discharge (DSN 001C), except for TRC (total residual chlorine), which is measured at MPS discharge (quarry cuts; DSN 001-1), and SWS FAC (service water system free available chlorine; DSN 001C-5).
(2)
Sodium hypochlorite injection secured the entire month for MPS3 refueling outage 3R22. No sampling performed.
Attachment to the 2023 Annual Environmental Operating Report January 1 - December 31, 2023 Executive Summary Section of Annual Report 2022 - Monitoring the Marine Environment of Long Island Sound at Millstone Power Station, Waterford, Connecticut dated July 2023
Executive Summary i Executive Summary This report summarizes results of ongoing environmental monitoring programs conducted in relation to the operation of Millstone Power Station (MPS). MPS can affect local marine biota in the following ways: large organisms may be impinged on the traveling screens that protect the condenser cooling and service water systems; smaller ones may be entrained through the condenser cooling-water system, which subjects them to various mechanical, thermal, and chemical effects; and marine communities in the discharge area may also be subjected to mechanical, thermal, and chemical effects resulting from the outflow of the cooling water.
This report contains a separate section for each major biological monitoring program, some of which have been conducted without interruption since 1976. These long-term studies have provided the representative data and scientific bases necessary to assess potential biological impacts as a result of MPS construction and operation.
In addition to sections related to the biological monitoring program, this report includes a section providing a complete and thorough description of all National Pollutant Discharge Elimination System (NPDES) permit compliance work undertaken for the implementation of flow reduction and/or entrainment mitigation technologies, operational methods or other measures undertaken in 2022, and a section which provides a comprehensive summary of activities and accomplishments of Dominion Energy Nuclear Connecticut (DENC) in the Niantic River Nitrogen Work Group effort.
Rocky Intertidal Studies Rocky intertidal habitats are extensive in the Millstone area, and support rich and diverse communities of attached algae and animals. Rocky intertidal studies at MPS are designed and implemented to characterize these communities.
Analyses of rocky shore data to date indicate that changes attributed to MPS operation are minor, transient, and restricted to a small area along 150 meters of shoreline in the immediate vicinity of the discharge.
As in previous years, seasonal shifts in occurrence of annual algal species were noted at Fox Island (FI) during 2022. These shifts included absence or abbreviated season for cold-water species (e.g.,
Protomonostroma undulatum, Spongomorpha arcta) and extended season for warm-water species (e.g., Hypnea musciformis).
Similar shifts have been observed in most years included in this time-series. However, some species with cold-water affinity (e.g.,
Protomonospora, Dumontia) occurred less regularly at Millstone Point (MP) and White Point (WP) as well, reflecting regional temperature increases compared to earlier study years.
Thermal effects on dominant species abundance and distribution patterns were also evident at FI in 2022, and most apparent in the low intertidal zone. Seasonally high abundance of Hypnea musciformis, a species observed for the first time in 2001, and expanded populations of Corallina officinalis now characterize the lower shore community at FI.
Melanothamnus (previously Neosiphonia) harveyi maintained a perennial population at all three sites in 2022.
Ascophyllum nodosum growth, represented as the most recent internodal length, was greatest at MP in 2022, followed by FI then WP. With all sites combined, growth in 2022 was lower than 2022, and was the lowest mean growth since this methodology began in 2011. This continues to demonstrate no clear relationships among monitoring sites, or correlation with station operating conditions, indicating that the thermal plume from MPS has had little effect on local populations. Natural influences of other factors, such as ambient temperature conditions, storms and wave action, nutrients and light, play the dominant role in determining Ascophyllum growing conditions in the Millstone area.
The rocky intertidal monitoring program has also documented regional patterns and modifications to shore communities unrelated to MPS operation.
These include the introduction to the region of three exotic red algae (Antithamnion pectinatum in
- 1986, Grateloupia turuturu in
- 2004, and Dasysiphonia japonica in 2010), decreases in barnacle abundance in more recent years, and long-term increases in abundance of the common seaweeds Fucus vesiculosus and Chondrus crispus.
Eelgrass Eelgrass (Zostera marina L.) was monitored at three locations in the vicinity of MPS. Data from 2022 surveys indicated that the two study sites nearest to the MPS thermal plume (Jordan Cove (JC) and White Point (WP)) supported healthy and
Executive Summary ii expansive eelgrass populations, consistent with results since the study began in 1985. While there has been moderate variability in abundance and distribution over the entire study period at these two sites, this variability was not related to MPS operation. Both predicted and measured thermal input to these sites from the cooling water discharge is at most minimal (< 1oC above ambient conditions) and well below levels considered stressful to eelgrass.
By comparison, high eelgrass population variability has been observed in the Niantic River, where complete and often sudden eelgrass bed losses were documented on six separate occasions prior to 2022. Data from the 2022 survey show continued recovery of some eelgrass beds in the Niantic River. Because the Niantic River is located well away from any influence of the MPS thermal plume, eelgrass population fluctuations there must be related to environmental factors such as increasing ambient seawater temperatures,
- disease, increased turbidity, and waterfowl grazing. Results from this monitoring therefore suggest that fluctuations in eelgrass populations observed at sites in the Niantic River are due to changes in local and regional environmental conditions and not to MPS operation.
Benthic Infauna Benthic infaunal monitoring during 2022 documented continuation of long-term trends in sediment characteristics at subtidal sites in the vicinity of MPS. The effluent sampling site (EF) sedimentary environment remained coarse, with low silt/clay which is related to discharge of cooling water into Long Island Sound (LIS) at the quarry cuts. Sediments at the intake site (IN) have been generally consistent with sediment characteristics prior to dredging during MPS Unit 3 (MPS3) construction, although the presence of pebbles and shell fragments resulted in higher mean grain sizes in the last three years. Sediments at Jordan Cove (JC) typically have the smallest mean grain size and highest silt/clay content of all four stations, attributed to the discharge area scouring and fine sediment deposition in the vicinity of the JC site. Sedimentary characteristics at the reference site at Giants Neck (GN) were similar to previous years observations and continued to reflect natural variability unrelated to MPS.
Dominant taxa at all sites were reflective of climax communities that have undergone long-term successional development in response to their sedimentary environments. Multidimensional scaling has shown distinct separation of communities affected by construction and initial operation of MPS3, but also illustrated regional temporal community shifts unrelated to MPS operation. Changes in community structure and functional group dominance at EF, JC, and IN reflect not only effects related to construction and initial operation of MPS3, but other regional and/or local biotic and abiotic factors. Community changes at GN were attributed solely to these latter factors, and not to MPS operation.
Lobster Studies Impacts associated with recent MPS operations on the local lobster population were assessed by comparing results of the 2022 study year to data collected from 1978 through 2021. Emphasis has been placed on assessing long-term trends in the relative abundance and population characteristics of lobsters collected in the Millstone Point area.
Throughout LIS, the lobster population was stable or increasing from 1978 through 1999. Commercial lobster catches in LIS precipitously declined from 2000 to 2013 and experienced a record low in 2021. In this study, lobsters in the MPS area have shown a similar trend, with relative abundance indices (catch per unit effort (CPUE)) approximately 75% lower in research pots and 99.7% lower in trawls during the past ten years (2013-2022),
compared to highest levels in the 1990s. Declines in pot and in trawl catches were unrelated to MPS operations and attributed to an increase in mortality associated with ambient seawater temperature rise and temperature mediated stressors that include a shell disease affecting lobster populations from eastern LIS to the Gulf of Maine. Egg-bearing females have been disproportionately and negatively impacted by shell disease in comparison to other lobsters. In addition, predation by the high number of Tautog caught in traps contributed to record high lobster mortality during 2015-2022.
Declines in the relative abundance of legal-size lobsters were attributed in part to the outbreak of shell disease and to a nearly 5 mm increase in the minimum legal-size since 1978. Long term reductions in landings of legal-size lobsters harvested by commercial lobster fishers in eastern LIS coincided with declines observed in this study, and lobster catches have remained severely depressed in other areas of LIS since the lobster die-off observed in 1999.
Long-term trends observed in lobster population characteristics during the past four decades
Executive Summary iii (molting, female size at
- maturity, relative abundance, and size characteristics of egg-bearing females) appear related to warmer ambient seawater temperatures and/or the recent outbreak of shell disease, and not MPS operations. Increased ambient water temperature may be responsible for the increased susceptibility and transmission of diseases affecting lobsters in LIS, which is at the southern boundary of their range of distribution in nearshore waters.
The number of lobster larvae entrained through the MPS cooling water systems was highly variable and very low in recent years, due to low adult lobster abundance (especially with adult females) and low larval densities throughout LIS. Impacts associated with impingement of lobsters at MPS have been greatly reduced by the use of aquatic organism return systems at both units, which return impinged lobsters to Niantic Bay with documented very high survival rates.
Fish Ecology Studies Results from the Fish Ecology monitoring program during suggest MPS operation has not had a discernible effect on local fish assemblages based on analysis of changes in community composition and long-term abundance trends.
Annual variations in ichthyoplankton entrainment likely reflected differences in spawning and transport of eggs and larvae within LIS. Other factors, such as extremes in seasonal water temperature, may also affect larval growth and development. A number of temporal and spatial changes were identified in the community of fishes and macroinvertebrates collected in the MPS trawl monitoring program. These changes were unrelated to the operations of MPS, but rather were associated with shifts in the dominance of individual taxa from changes in habitat, range extensions or contractions related to a warming trend in ambient seawater temperature, and changes in fishing rates and fishing regulations.
The magnitude of entrainment is dependent upon egg and larval densities and condenser cooling water flows during their periods of occurrence. Reductions in cooling-water flows have been implemented at MPS with the use of variable frequency drives and timed refueling outages during the peak period of Winter Flounder annual spawning. In addition to the Unit 3 fish return, which was in operation at unit start-up in 1986, impingement was further reduced at MPS with the installation of a fish return at Unit 2 in early 2000.
Implementation of these mitigation measures serves to minimize entrainment and impingement at MPS.
Winter Flounder Studies Various life history stages of Winter Flounder have been monitored since 1976 to determine what effect, if any, MPS may have on the local Niantic River population, particularly through the entrainment of larvae. Over the past two decades, low Winter Flounder abundance levels have been found throughout LIS by the Connecticut Department of Energy and Environmental Protection (CTDEEP). During the same time period, adult Winter Flounder abundance in the Niantic River has remained low. Reflecting the continued trend of low abundance, the -mean Catch Per Unit Effort (CPUE) for both adult
(>15cm) and juvenile (<15cm) fish captured in the year-round Trawl Monitoring Program (TMP) in 2022 were low (1.8 and 0.7, respectively). 2022 densities of settled young in the Niantic River, sampled by the Age-0 beam trawl survey, were the highest values since 2007, but were low for the overall time-series.
The number of larvae entrained at MPS is a measure of potential impact to Winter Flounder.
Annual estimates of entrainment are related to both larval densities in Niantic Bay and MPS cooling-water volume. The 2022 entrainment estimate was 98.7 million larvae. Reduced entrainment in spring 2022 can be attributed to reduced cooling water volumes from the use of the variable frequency drives (VFD) during the Interval from April 4 - May 14 in addition to the Unit 3 refueling outage, which lasted from April 7 to June 4 (see NPDES Permit Compliance section). As a result of VFD use during the Interval, Winter Flounder larval entrainment was reduced 67.5% when compared to that expected under baseline total permitted flow.
Processes that are unrelated to MPS operation and which occur after juvenile Winter Flounder leave shallow nursery waters during the fall of their first year of life seem to be operating to account for fewer adults. A bottleneck in recruitment may occur during the late juvenile life stage (ages-1 and 2), probably from predation. Environmental effects, including changes to the Niantic River habitat (e.g.,
widely fluctuating eelgrass abundance), a warming trend in regional seawater temperature, and interactions with other species (e.g., predation), especially during early life
Executive Summary iv history, are also important processes affecting Winter Flounder population dynamics.
Results from Winter Flounder studies through 2022 suggest that MPS operations have had minimal effects on Winter Flounder biomass in the Niantic River. Declines in stock size have been greatly evident on a regional basis, including LIS, Rhode Island and all other Southern New England waters. Entrainment during the larval life stages of Winter Flounder occurs, however there has been large variation in the amount of larval mortality and recruitment in recent years, both occurring independently of MPS operations.