Text
Mr. Ross Moore Director of Regulatory Affairs Oklo Inc.
3190 Coronado Dr.
Santa Clara, CA 95054
SUBJECT:
OKLO INC. - U.S. NUCLEAR REGULATORY COMMISSION STAFF FEEDBACK AND OBSERVATIONS ON THE OKLO WHITE PAPER FOR PRE-APPLICATION ENGAGEMENT, CONSIDERATIONS FOR INCLUDING PRINCIPAL DESIGN CRITERIA IN THE LICENSING BASIS IN 10 CFR PART 52
Dear Mr. Moore:
By letter dated October 31, 2023 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML23304A212), Oklo Inc. (Oklo) submitted a white paper, Considerations for Including Principal Design Criteria in the Licensing Basis in 10 CFR Part 52, for the U.S. Nuclear Regulatory Commission (NRC) staffs feedback and observations.
The white paper describes, from historical perspective, the principal design criteria (PDC) and the General Design Criteria to which the PDC of the current fleet conform and compares the relationship of the PDC to the licensing bases of both construction permits and operating licenses issued under Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic licensing of production and utilization facilities and combined licenses issued under 10 CFR Part 52, Licenses, certifications, and approvals for nuclear power plants. Oklo also provided specific questions that it wanted the NRC staff to address in its feedback.
The enclosure to this letter provides the NRC staffs feedback and observations on the October 31, 2023, white paper for Oklo to consider as part of any future submittal that may address this topic.
May 28, 2024
R. Moore If you have questions regarding this matter, please contact Donna Williams at (301) 415-1322 or via email at Donna.Williams@nrc.gov.
Sincerely, Joshua Borromeo, Chief Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Project No.: 99902095
Enclosure:
As stated cc: Ross@Oklo.com w/o encl: via GovDelivery for Oklo Signed by Borromeo, Joshua on 05/28/24
Package: ML24071A061 Letter: ML24071A064
Enclosure:
ML24071A066 NRR-106 OFFICE NRR/DANU/UAL1:PM NRR/DANU/UAL1:LA NRR/DANU/UARPBC NAME DWilliams DGreene SLynch DATE 03/11/2024 03/14/2024 04/09/2024 OFFICE NRR/DANU/UTB2:BC OGC NRR/DANU/UAL1:BC NAME CdeMessieres MASpencer JBorromeo DATE 05/10/2024 03/07/2024 05/28/2024