LES-24-028-NRC Urenco USA Inc.
UUI l P.O. Box 1789 l 275 Hwy. 176 l Eunice l New Mexico l 88231 l USA T: +1 (575) 394-4646 l W: www.urencousa.com
© 2024 Urenco USA Inc.
1 2/29/2024 ATTN: Document Control Desk Director Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Louisiana Energy Services, LLC NRC Docket No. 70-3103
Subject:
Semi-Annual Radiological Effluent Release Report for July 1, 2023 through December 31, 2023 Pursuant to 10 CFR 70.59, Louisiana Energy Services, LLC, also dba Urenco USA, herewith submits the subject report. Enclosure 1 specifies the quantities released of licensed principal radionuclides in liquid or gaseous form, to uncontrolled areas.
Should there be any questions regarding this submittal, please contact John Pfabe, Senior Licensing Specialist at 575.394.6061.
Respectfully, Chris Schwarz Licensing and ECP Manager
Enclosure:
- 1. Semi-Annual Radiological Effluent Release Report for July 1, 2023 through December 31, 2023 CC:
USNRC Region II RidsRgn2MailCenter@nrc.gov Jonathan Rowley, Senior Project Manager - UUSA U.S. Nuclear Regulatory Commission Jonathan.Rowley@NRC.gov
LES-24-028-NRC Urenco USA Inc.
UUI l P.O. Box 1789 l 275 Hwy. 176 l Eunice l New Mexico l 88231 l USA T: +1 (575) 394-4646 l W: www.urencousa.com
© 2024 Urenco USA Inc.
3 ENCLOSURE 1 Semi-Annual Radiological Effluent Release Report for July 1, 2023 through December 31, 2023
URENCO USA: Report of Radioactivity in Effluents: Liquid & Air: July 2023 - December 2023 There were no releases to the public during the reporting period that exceeded regulatory requirements, and detected isotopic uranium activities were comparable to pre-operational activities. No dose assessment was performed because the maximum potential dose directly at the point of gaseous and liquid effluent discharge points were acceptable. The potential maximum doses directly at the discharge points for both liquid and gaseous effluent were shown to be less than 10% of the radionuclide concentration dose.
In liquid effluent, the concentrations of isotopic uranium were below the Minimum Detectable Concentration (MDC) and therefore below the values listed in 10 CFR 20, Appendix B, Table 3, Releases to Sewers (Table 1-1).
In gaseous effluent, the gross uranium activity was either below the Minimum Detectable Activity (MDA) or less than 10% of values listed in 10 CFR 20, Appendix B, Table 2, Effluent Concentrations - Class D Air for U234, U235, and U238.
The concentrations of isotopic uranium in gaseous effluent was either below the Minimum Detectable Concentration (MDC) or less than 10% of values listed in 10 CFR 20.1301, 10 CFR 20.1302, and 10 CFR 20.1101(d), as described in NRC Regulatory Guide 4.20 Constraint on Releases of Airborne Radioactive Materials to the Environment for Licensees other than Power Reactors dated December 1996.
LIST OF TABLES Table No.
Title 1-1 Lift Station 1 Wastewater Effluent - Radionuclides Quarters 3 & 4, 2023 1-2 Separations Building Module-1001 (SBM 1001): Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1MA1 & 1001-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2023 1-3 Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1MA1 & 1003-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2023 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1MA1 & 1005-562-1MA2 Gross Alpha & Beta, and Radionuclides Quarters: 3 & 4, 2023 1-5 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1MA1 & 1100-562-1MA2 - Gross Alpha &
Beta, and Radionuclides: Quarters 3 & 4, 2023 1-6 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100): Fume Hood Exhaust Gaseous Effluent Vent System, 1100-562-2MA1 & 1100-562-2MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2023
TABLE 1-1 Lift Station 1 Wastewater Effluent - Radionuclides, Quarters 3 & 4, 2023 URENCO USA Lea County, New Mexico Radionuclide Sample Date (Date/Time)
Sample Period Total Time (days)
Results (Ci/ml)
Counting Uncertainty (Ci/ml)
Total Flow*
(gallons/day)
Quantity Released (Ci)
Uranium - 233/234 0.00E+00 0.00E+00 13,000 Result Below LLD Uranium - 235/236 0.00E+00 0.00E+00 13,000 Result Below LLD Uranium - 238 0.00E+00 0.00E+00 13,000 Result Below LLD Uranium - 233/234 0.00E+00 0.00E+00 13,000 Result Below LLD Uranium - 235/236 0.00E+00 0.00E+00 13,000 Result Below LLD Uranium - 238 0.00E+00 0.00E+00 13,000 Result Below LLD Comments URENCO USA Lea County New Mexico Lift Station 1 WasteWater Effluent-Radionuclides
% of Table 3 of Appendix B to 10 CFR 20 Values-Monthly Average Release to Sewers 1Lift Station 1 - July - December 2023 7/01/23 -
12/31/23 12/21/2023 1023 Result Below LLD Result Below LLD Result Below LLD 7/01/23 -
12/31/23 183 Result Below LLD All sample results returned Not Detectable 12/21/2023 1023 Result Below LLD Lift Station 1 Duplicate - July - December 2023 Result Below LLD 183 Notes:
- 1.
- = Table 3.4-4 Anticipated Normal Plant Water Consumption from the Environmental Report, Rev. 23, lists Total Personnel Water Use as approximately 13,000 gallons per day.
- 2.
µCi/mL = microCuries per milliliter.
- 3.
Radionuclides analyzed using method EICHROM AC01 by Cardinal Laboratories of Hobbs, NM.
- 4.
Quantity released is calculated if the result equals or exceeds the LLD. Facility-required lower level of detection (LLD) is 3.09E-9 µCi/mL.
TABLE 1-2 Separations Building Module-1001 (SBM 1001): Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1MA1 & 1001-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2023 URENCO USA Lea County, New Mexico.
Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)
Sample Period Analyte Gross Result (Ci/ml)
MDA (Ci/ml)
@ 95 CL Instrument Unc (Ci/ml)
Total Vent System Flow (m3)
Quantity Released (Ci)
% of Table 2 of Appendix B to 10 CFR 20 Values 10015621MA1 070623 09/01/2023 1017 07/06/23 - 09/01/23 7.45E-17 2.69E-16 9.91E-08 6.91E+05
<MDA
<MDA 10015621MA1 090123 10/09/223 1038 09/01/23 - 10/09/23 5.16E-17 3.86E-16 6.76E-08 5.25E+05
<MDA
<MDA 10015621MA1 100923 11/06/2023 1050 10/09/23 - 11/06/23 0.00E+00 5.74E-16 0.00E+00 3.88E+05
<MDA
<MDA 10015621MA1 110623 12/11/2023 0959 11/06/23 - 12/11/23 1.25E-16 4.52E-16 9.91E-08 4.85E+05
<MDA
<MDA 10015621MA1 121123 01/05/2024 1058 12/11/23 - 01/05/24 0.00E+00 6.26E-16 0.00E+00 3.46E+05
<MDA
<MDA 10015621MA1 070623 09/01/2023 1017 07/06/23 - 09/01/23 3.10E-15 2.56E-15 1.73E-08 6.91E+05 2.14E-09 0.103%
10015621MA1 090123 10/09/223 1038 09/01/23 - 10/09/23 4.02E-15 3.68E-15 1.74E-06 5.25E+05 2.11E-09 0.134%
10015621MA1 100923 11/06/2023 1050 10/09/23 - 11/06/23 3.70E-15 5.46E-15 1.55E-06 3.88E+05
<MDA
<MDA 10015621MA1 110623 12/11/2023 0959 11/06/23 - 12/11/23 5.74E-15 4.30E-15 1.82E-06 4.85E+05 2.78E-09 0.191%
10015621MA1 121123 01/05/2024 1058 12/11/23 - 01/05/24 7.39E-15 5.97E-15 1.79E-06 3.46E+05 2.55E-09 0.246%
10015621MA2 070623 09/01/2023 1022 07/06/23 - 09/01/23 1.35E-16 1.01E-15 6.76E-08 1.63E+05
<MDA
<MDA 10015621MA2 090123 10/09/2023 1040 09/01/23 - 10/09/23
-7.60E-17 3.29E-16 4.16E-10 6.21E+05
<MDA
<MDA 10015621MA2 100923 11/06/2023 1102 10/09/23 - 11/06/23 6.69E-17 5.01E-16 6.76E-08 4.55E+05
<MDA
<MDA 10015621MA2 110623 12/11/2023 1005 11/06/23 - 12/11/23 0.00E+00 4.02E-16 0.00E+00 5.73E+05
<MDA
<MDA 10015621MA2 121123 01/05/2024 1110 12/11/23 - 01/05/24 6.91E-17 5.17E-16 6.76E-08 4.10E+05
<MDA
<MDA 10015621MA2 070623 09/01/2023 1022 07/06/23 - 09/01/23 7.45E-15 9.62E-15 1.58E-06 1.63E+05
<MDA
<MDA 10015621MA2 090123 10/09/2023 1040 09/01/23 - 10/09/23 2.01E-15 3.13E-15 1.86E-06 6.21E+05
<MDA
<MDA 10015621MA2 100923 11/06/2023 1102 10/09/23 - 11/06/23 3.92E-15 4.77E-15 1.59E-06 4.55E+05
<MDA
<MDA 10015621MA2 110623 12/11/2023 1005 11/06/23 - 12/11/23 2.59E-15 3.83E-15 1.55E-06 5.73E+05
<MDA
<MDA 10015621MA2 121123 01/05/2024 1110 12/11/23 - 01/05/24 5.00E-15 4.93E-15 1.66E-06 4.10E+05 2.05E-09 0.167%
Gross Beta Gross Alpha Seperations Building Module - 1001 (SBM 1001) Pumped Extract Exhaust (PXGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta 1001-562-1MA2 Gross Beta 1001-562-1MA1 Gross Alpha Radionuclide Sample Date (Off Date)
Sample Period Result (Ci/ml)
Uncertainty (2 TPU)
(Ci/ml)
Uncertainty (1 TPU)
(Ci/ml)
MDC (Ci/ml)
Total Flow (m3)
Quantity Released (Ci)
Uranium-233/234 3rd Qtr 2023 3.87E-16 1.60E-16 1.63E-16 9.15E-17 0.00 Uranium-235/236 3rd Qtr 2023 5.55E-17 6.73E-17 6.74E-17 8.30E-17 Result Below MDC Uranium-238 3rd Qtr 2023 3.47E-16 1.49E-16 1.51E-16 6.72E-17 0.00 Uranium-233/234 4th Qtr 2023 3.12E-16 1.47E-16 1.49E-16 9.00E-17 0.00 Uranium-235/236 4th Qtr 2023 6.25E-17 8.18E-17 8.19E-17 1.25E-16 Result Below MDC Uranium-238 4th Qtr 2023 2.13E-16 1.21E-16 1.22E-16 8.17E-17 0.00 Uranium-233/234 3rd Qtr 2023 5.20E-16 1.65E-16 1.70E-16 7.43E-17 0.00 Uranium-235/236 3rd Qtr 2023 2.78E-17 4.28E-17 4.28E-17 6.45E-17 Result Below MDC Uranium-238 3rd Qtr 2023 3.56E-16 1.34E-16 1.37E-16 5.22E-17 0.00 Uranium-233/234 4th Qtr 2023 2.89E-16 9.49E-17 9.71E-17 3.63E-17 0.00 Uranium-235/236 4th Qtr 2023 1.85E-17 3.14E-17 3.14E-17 5.53E-17 Result Below MDC Uranium-238 4th Qtr 2023 2.25E-16 8.39E-17 8.54E-17 4.55E-17 0.00 1/5/2024 7/6/23 - 10/9/23 10/9/23 - 1/5/24 Result Below MDC 0.01%
0.01%
Result Below MDC 1.22E+06 1.22E+06 0.01%
10/9/2023 7/6/23 - 10/9/23
% of Table 2 of Appendix B to 10 CFR 20 Values 1/5/2024 0.01%
Result Below MDC 0.01%
10/9/23 - 1/5/24 10/9/2023 7.85E+05 1.44E+06 0.01%
0.01%
0.02%
Result Below MDC Sample ID: 1001-562-1MA1 Seperations Building Module - 1001 (SBM 1001) Pumped Extract Exhaust (PXGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta Sample ID: 1001-562-1MA2 Notes:
1001-562-1MA1: Filter change-out in August did not occur due to unit maintenance.
1001-562-1MA2: Filter change-out in August did not occur due to redundant monitor (1001-562-1MA1) maintenance.
TABLE 1-3 Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1MA1 &
1003-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2023 URENCO USA Lea County, New Mexico Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)
Sample Period Analyte Gross Result (Ci/ml)
MDA (Ci/ml)
@ 95 CL Instrument Unc (Ci/ml)
Total Vent System Flow (m3)
Quantity Released (Ci)
% of Table 2 of Appendix B to 10 CFR 20 Values 10035621MA1 070623 08/02/2023 1236 07/06/23 - 08/02/23 0.00E+00 4.52E-16 0.00E+00 3.96E+05
<MDA
<MDA 10035621MA1 080223 09/01/2023 1050 08/02/23 - 09/01/23 5.37E-17 4.02E-16 6.76E-08 3.64E+05
<MDA
<MDA 10035621MA1 090123 10/09/2023 1115 09/01/23 - 10/09/23 1.10E-17 2.75E-16 2.07E-07 4.71E+05
<MDA
<MDA 10035621MA1 100923 11/06/2023 1119 10/09/23 - 11/06/23 2.37E-16 4.36E-16 1.40E-07 4.31E+05
<MDA
<MDA 10035621MA1 110623 12/11/2023 1015 11/06/23 - 12/11/23 0.00E+00 3.47E-16 0.00E+00 5.41E+05
<MDA
<MDA 10035621MA1 121123 01/05/2024 1348 12/11/23 - 01/05/24 6.56E-17 4.91E-16 6.76E-08 3.72E+05
<MDA
<MDA 10035621MA1 070623 08/02/2023 1236 07/06/23 - 08/02/23 4.15E-15 4.30E-15 1.64E-06 3.96E+05
<MDA
<MDA 10035621MA1 080223 09/01/2023 1050 08/02/23 - 09/01/23 2.40E-15 3.83E-15 1.53E-06 3.64E+05
<MDA
<MDA 10035621MA1 090123 10/09/2023 1115 09/01/23 - 10/09/23 2.26E-15 2.62E-15 1.91E-06 4.71E+05
<MDA
<MDA 10035621MA1 100923 11/06/2023 1119 10/09/23 - 11/06/23 2.21E-15 4.16E-15 1.49E-06 4.31E+05
<MDA
<MDA 10035621MA1 110623 12/11/2023 1015 11/06/23 - 12/11/23 2.23E-15 3.30E-15 1.55E-06 5.41E+05
<MDA
<MDA 10035621MA1 121123 01/05/2024 1348 12/11/23 - 01/05/24 4.75E-15 4.68E-15 1.66E-06 3.72E+05 1.77E-09 0.158%
10035621MA2 070623 08/02/2023 1245 07/06/23 - 08/02/23 1.64E-16 5.94E-16 9.91E-08 4.37E+05
<MDA
<MDA 10035621MA2 080223 09/01/2023 1055 08/02/23 - 09/01/23 1.21E-16 4.36E-16 9.91E-08 3.54E+05
<MDA
<MDA 10035621MA2 090123 10/09/2023 1120 09/01/23 - 10/09/23 8.14E-17 2.94E-16 9.91E-08 4.50E+05
<MDA
<MDA 10035621MA2 100923 11/06/2023 1128 10/09/23 - 11/06/23 1.13E-16 4.08E-16 9.91E-08 4.53E+05
<MDA
<MDA 10035621MA2 110623 12/11/2023 1020 11/06/23 - 12/11/23 1.30E-16 3.18E-16 1.22E-07 5.79E+05
<MDA
<MDA 10035621MA2 121123 01/05/2024 1354 12/11/23 - 01/05/24 0.00E+00 3.98E-16 0.00E+00 4.04E+05
<MDA
<MDA 10035621MA2 070623 08/02/2023 1245 07/06/23 - 08/02/23 5.74E-15 5.66E-15 1.66E-06 4.37E+05 2.51E-09 0.191%
10035621MA2 080223 09/01/2023 1055 08/02/23 - 09/01/23 3.01E-15 4.16E-15 1.56E-06 3.54E+05
<MDA
<MDA 10035621MA2 090123 10/09/2023 1120 09/01/23 - 10/09/23 2.70E-15 2.80E-15 1.64E-06 4.50E+05
<MDA
<MDA 10035621MA2 100923 11/06/2023 1128 10/09/23 - 11/06/23 4.81E-15 3.89E-15 1.79E-06 4.53E+05 2.18E-09 0.160%
10035621MA2 110623 12/11/2023 1020 11/06/23 - 12/11/23 2.35E-15 3.03E-15 1.58E-06 5.79E+05
<MDA
<MDA 10035621MA2 121123 01/05/2024 1354 12/11/23 - 01/05/24 3.30E-15 3.80E-15 1.61E-06 4.04E+05
<MDA
<MDA 1003-562-1MA2 1003-562-1MA1 Gross Beta Gross Alpha Gross Alpha Gross Beta Seperations Building Module -1003 (SBM 1003) Pumped Extract Exhaust (PXGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta Radionuclide Sample Date (Off Date)
Sample Period Result (Ci/ml)
Uncertainty (2 sigma)
(Ci/ml)
Uncertainty (1 sigma)
(Ci/ml)
MDC (Ci/ml)
Total Flow (m3)
Quantity Released (Ci)
Uranium-233/234 3rd Qtr 2023 1.74E-16 6.14E-17 6.27E-17 2.99E-17 0.00 Uranium-235/236 3rd Qtr 2023 2.75E-17 2.87E-17 2.87E-17 3.69E-17 Result Below MDC Uranium-238 3rd Qtr 2023 2.02E-16 6.59E-17 6.74E-17 2.20E-17 0.00 Uranium-233/234 4th Qtr 2023 2.62E-16 1.00E-16 1.02E-16 6.47E-17 0.00 Uranium-235/236 4th Qtr 2023 1.01E-17 3.20E-17 3.20E-17 7.07E-17 Result Below MDC Uranium-238 4th Qtr 2023 2.43E-16 9.48E-17 9.63E-17 5.11E-17 0.00 Uranium-233/234 3rd Qtr 2023 3.07E-16 9.14E-17 9.40E-17 3.13E-17 0.00 Uranium-235/236 3rd Qtr 2023 0.00E+00 2.21E-17 2.21E-17 4.77E-17 Result Below MDC Uranium-238 3rd Qtr 2023 3.59E-16 9.92E-17 1.02E-16 2.72E-17 0.00 Uranium-233/234 4th Qtr 2023 1.50E-16 6.33E-17 6.42E-17 3.69E-17 0.00 Uranium-235/236 4th Qtr 2023
-7.14E-18 1.68E-17 1.68E-17 4.84E-17 Result Below MDC Uranium-238 4th Qtr 2023 8.75E-17 4.78E-17 4.82E-17 3.11E-17 0.00 0.01%
% of Table 2 of Appendix B to 10 CFR 20 Values 10/9/2023 1.23E+06 1.34E+06 1003-562-1MA2 0.01%
0.00%
Seperations Building Module -1003 (SBM 1003) Pumped Extract Exhaust (PXGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta 10/9/2023 1003-562-1MA1 10/9/23 - 1/5/24 0.01%
0.00%
Result Below MDC Result Below MDC 7/6/23 - 10/9/23 1.44E+06 0.01%
0.01%
1/5/2024 1.24E+06 Result Below MDC Result Below MDC 1/5/2024 7/6/23 - 10/9/23 10/9/23 - 1/5/24 0.01%
Notes: None
TABLE 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1MA1 &
1005-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2023 URENCO USA Lea County, New Mexico Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)
Sample Period Analyte Gross Result (Ci/ml)
MDA (Ci/ml)
@ 95 CL Instrument Unc (Ci/ml)
Total Vent System Flow (m3)
Quantity Released (Ci)
% of Table 2 of Appendix B to 10 CFR 20 Values 10055621MA1 070623 08/02/2023 1256 07/06/23 - 08/02/23
-2.61E-18 5.06E-16 6.76E-08 7.12E+05
<MDA
<MDA 10055621MA1 080223 09/01/2023 1134 08/02/23 - 09/01/23 2.46E-16 4.52E-16 1.40E-07 8.01E+05
<MDA
<MDA 10055621MA1 090123 10/09/2023 1130 09/01/23 - 10/09/23 4.79E-17 3.59E-16 6.76E-08 9.80E+05
<MDA
<MDA 10055621MA1 100923 11/06/2023 1136 10/09/23 - 11/06/23 6.44E-37 4.82E-16 6.76E-08 7.34E+05
<MDA
<MDA 10055621MA1 110623 12/11/2023 1035 11/06/23 - 12/11/23 0.00E+00 3.75E-16 0.00E+00 9.35E+05
<MDA
<MDA 10055621MA1 121123 01/05/2024 1343 12/11/23 - 01/05/24 2.18E-16 5.33E-16 1.22E-07 6.83E+05
<MDA
<MDA 10055621MA1 070623 08/02/2023 1256 07/06/23 - 08/02/23 3.55E-15 4.82E-15 1.68E-06 7.12E+05
<MDA
<MDA 10055621MA1 080223 09/01/2023 1134 08/02/23 - 09/01/23 3.95E-15 4.30E-15 1.63E-06 8.01E+05
<MDA
<MDA 10055621MA1 090123 10/09/2023 1130 09/01/23 - 10/09/23 3.13E-15 3.42E-15 1.63E-06 9.80E+05
<MDA
<MDA 10055621MA1 100923 11/06/2023 1136 10/09/23 - 11/06/23 5.54E-15 4.59E-15 1.73E-06 7.34E+05 4.07E-09 0.185%
10055621MA1 110623 12/11/2023 1035 11/06/23 - 12/11/23 3.10E-15 3.57E-15 1.61E-06 9.35E+05
<MDA
<MDA 10055621MA1 121123 01/05/2024 1343 12/11/23 - 01/05/24 4.65E-15 5.07E-15 1.63E-06 6.83E+05
<MDA
<MDA 10055621MA2 070623 08/02/2023 1300 07/06/23 - 08/02/23 1.48E-16 5.36E-16 9.91E-08 7.29E+05
<MDA
<MDA 10055621MA2 080223 09/02/2023 1139 08/02/23 - 09/01/23 1.32E-16 4.77E-16 9.91E-08 8.14E+05
<MDA
<MDA 10055621MA2 090123 10/09/2023 1135 09/01/23 - 10/09/23 5.04E-17 3.78E-16 6.76E-08 1.01E+06
<MDA
<MDA 10055621MA2 100923 11/06/2023 1142 10/09/23 - 11/06/23 0.00E+00 5.08E-16 0.00E+00 7.55E+05
<MDA
<MDA 10055621MA2 110623 12/11/2023 1040 11/06/23 - 12/11/23 5.28E-17 3.95E-16 6.76E-08 9.67E+05
<MDA
<MDA 10055621MA2 121123 01/05/2024 1345 12/11/23 - 01/05/24 0.00E+00 3.98E-16 0.00E+00 4.04E+05
<MDA
<MDA 10055621MA2 070623 08/02/2023 1300 07/06/23 - 08/02/23 4.68E-15 5.11E-15 1.63E-06 7.29E+05
<MDA
<MDA 10055621MA2 080223 09/02/2023 1139 08/02/23 - 09/01/23 2.11E-15 4.55E-15 1.53E-06 8.14E+05
<MDA
<MDA 10055621MA2 090123 10/09/2023 1135 09/01/23 - 10/09/23 4.34E-15 3.60E-15 1.73E-06 1.01E+06 4.40E-09 0.145%
10055621MA2 100923 11/06/2023 1142 10/09/23 - 11/06/23 4.66E-16 4.84E-15 1.32E-06 7.55E+05
<MDA
<MDA 10055621MA2 110623 12/11/2023 1040 11/06/23 - 12/11/23 5.45E-15 3.77E-15 1.80E-06 9.67E+05 5.27E-09 0.182%
10055621MA2 121123 01/05/2024 1345 12/11/23 - 01/05/24 4.33E-15 3.80E-15 1.76E-06 4.04E+05 1.75E-09 0.144%
1005-562-1MA1 Gross Alpha Gross Beta Gross Alpha Seperations Building Module -1005 (SBM 1005) Pumped Extract Exhaust (PXGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta Gross Beta 1005-562-1MA2 Radionuclide Sample Date (Off Date)
Sample Period Result (Ci/ml)
Uncertainty (2 sigma)
(Ci/ml)
Uncertainty (1 sigma)
(Ci/ml)
MDC (Ci/ml)
Total Flow (m3)
Quantity Released (Ci)
Uranium-233/234 3rd Qtr 2023 2.98E-16 9.04E-17 9.28E-17 3.17E-17 0.00 Uranium-235/236 3rd Qtr 2023 1.61E-17 2.74E-17 2.74E-17 4.83E-17 Result Below MDC Uranium-238 3rd Qtr 2023 1.75E-16 6.80E-17 6.91E-17 2.75E-17 0.00 Uranium-233/234 4th Qtr 2023 2.42E-16 9.06E-17 9.23E-17 4.91E-17 5.70E-10 Uranium-235/236 4th Qtr 2023 3.62E-17 3.94E-17 3.95E-17 4.82E-17 Result Below MDC Uranium-238 4th Qtr 2023 2.16E-16 8.75E-17 8.88E-17 6.39E-17 0.00E+00 Uranium-233/234 3rd Qtr 2023 1.83E-16 8.50E-17 8.60E-17 4.11E-17 0.00 Uranium-235/236 3rd Qtr 2023 1.20E-17 3.33E-17 3.33E-17 7.20E-17 Result Below MDC Uranium-238 3rd Qtr 2023 1.75E-16 8.46E-17 8.55E-17 5.82E-17 0.00 Uranium-233/234 4th Qtr 2023 3.03E-16 9.90E-17 1.01E-16 3.29E-17 6.44E-10 Uranium-235/236 4th Qtr 2023 5.77E-17 5.01E-17 5.03E-17 5.77E-17 0.00 Uranium-238 4th Qtr 2023 2.65E-16 9.31E-17 9.50E-17 4.67E-17 0.00E+00 0.01%
0.009%
0.00%
Result Below MDC 0.01%
2.49E+06 2.35E+06 2.56E+06 2.13E+06 7/6/23 - 10/9/23 0.01%
10/9/23 - 1/5/24 10/9/2023 1005-562-1MA1 1/5/2024 0.010%
7/6/23 - 10/9/23 10/9/23 - 1/5/24 Seperations Building Module -1005 (SBM 1005) Pumped Extract Exhaust (PXGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta 1/5/2024 0.007%
0.008%
% of Table 2 of Appendix B to 10 CFR 20 Values 10/9/2023 Result Below MDC 1005-562-1MA2 Result Below MDC 0.01%
Notes: None
TABLE 1-5 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1MA1 &
1100-562-1MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2023 URENCO USA Lea County, New Mexico Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)
Sample Period Analyte Gross Result (Ci/ml)
MDA (Ci/ml)
@ 95 CL Instrument Unc (Ci/ml)
Total Vent System Flow (m3)
Quantity Released (Ci)
% of Table 2 of Appendix B to 10 CFR 20 Values 11005621MA1 070623 08/02/2023 1310 07/06/23 - 08/02/23 2.35E-16 4.32E-16 1.40E-07 6.67E+05
<MDA
<MDA 11005621MA1 080223 09/01/2023 1144 08/02/23 - 09/01/23 5.20E-17 3.89E-16 6.76E-08 7.34E+05
<MDA
<MDA 11005621MA1 090123 10/09/2023 1100 09/01/23 - 10/09/23 0.00E+00 3.12E-16 0.00E+00 9.67E+05
<MDA
<MDA 11005621MA1 100923 11/07/2023 0940 10/09/23 - 11/07/23 5.32E-17 3.98E-16 6.76E-08 7.23E+05
<MDA
<MDA 11005621MA1 110723 12/11/2023 1050 11/07/23 - 12/11/23 6.65E-17 3.40E-16 9.91E-08 8.60E+05
<MDA
<MDA 11005621MA1 121123 01/05/2024 1358 12/11/23 - 01/05/24 1.90E-16 4.64E-16 1.22E-07 6.11E+05
<MDA
<MDA 11005621MA1 070623 08/02/2023 1310 07/06/23 - 08/02/23 4.18E-15 4.12E-15 1.66E-06 6.67E+05 2.79E-09 0.139%
11005621MA1 080223 09/01/2023 1144 08/02/23 - 09/01/23 1.61E-15 3.71E-15 1.46E-06 7.34E+05
<MDA
<MDA 11005621MA1 090123 10/09/2023 1100 09/01/23 - 10/09/23 3.45E-15 2.98E-15 1.71E-06 9.67E+05 3.34E-09 0.115%
11005621MA1 100923 11/07/2023 0940 10/09/23 - 11/07/23 2.02E-15 3.80E-15 1.49E-06 7.23E+05
<MDA
<MDA 11005621MA1 110723 12/11/2023 1050 11/07/23 - 12/11/23 2.18E-15 3.23E-15 1.65E-06 8.60E+05
<MDA
<MDA 11005621MA1 121123 01/05/2024 1358 12/11/23 - 01/05/24 4.70E-15 4.42E-15 1.68E-06 6.11E+05 2.87E-09 0.157%
11005621MA2 070623 08/02/2023 1315 07/06/23 - 08/02/23 0.00E+00 6.12E-16 0.00E+00 2.31E+05
<MDA
<MDA 11005621MA2 080223 09/01/2023 1146 08/02/23 - 09/01/23
-6.93E-17 4.87E-16 2.59E-10 4.77E+05
<MDA
<MDA 11005621MA2 090123 10/09/2023 1103 09/01/23 - 10/09/23 0.00E+00 5.16E-16 0.00E+00 1.17E+05
<MDA
<MDA 11005621MA2 100923 11/07/2023 1040 10/09/23 - 11/07/23 1.93E-16 4.73E-16 1.22E-07 6.08E+05
<MDA
<MDA 11005621MA2 110723 12/11/2023 1053 11/07/23 - 12/11/23 5.32E-17 3.98E-16 6.76E-08 7.53E+05
<MDA
<MDA 11005621MA2 121123 01/05/2024 1400 12/11/23 - 01/05/24 1.56E-16 5.65E-16 9.91E-08 4.69E+05
<MDA
<MDA 11005621MA2 070623 08/02/2023 1315 07/06/23 - 08/02/23 7.32E-15 5.83E-15 1.74E-06 2.31E+05 1.69E-09 0.244%
11005621MA2 080223 09/01/2023 1146 08/02/23 - 09/01/23 1.62E-15 4.63E-15 1.55E-06 4.77E+05
<MDA
<MDA 11005621MA2 090123 10/09/2023 1103 09/01/23 - 10/09/23 6.40E-15 4.91E-15 1.76E-06 1.17E+05 7.46E-10 0.213%
11005621MA2 100923 11/07/2023 1040 10/09/23 - 11/07/23 6.52E-15 4.50E-15 1.80E-06 6.08E+05 3.97E-09 0.217%
11005621MA2 110723 12/11/2023 1053 11/07/23 - 12/11/23 3.97E-15 3.80E-15 1.73E-06 7.53E+05 2.99E-09 0.132%
11005621MA2 121123 01/05/2024 1400 12/11/23 - 01/05/24 5.19E-15 5.38E-15 1.64E-06 4.69E+05
<MDA
<MDA Gross Beta Gross Alpha 1100-562-1MA2 Gross Beta 1100-562-1MA1 Container Receipt and Dispatch Building -1100 (CRDB 1100) Exhaust (FHGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta Gross Alpha Radionuclide Sample Date (Off Date)
Sample Period Result (Ci/ml)
Uncertainty (2 sigma)
(Ci/ml)
Uncertainty (1 sigma)
(Ci/ml)
MDC (Ci/ml)
Total Flow (m3)
Quantity Released (Ci)
Uranium-233/234 3rd Qtr 2023 2.30E-16 8.18E-17 8.35E-17 4.57E-17 0.00 Uranium-235/236 3rd Qtr 2023 1.38E-17 2.37E-17 2.37E-17 4.07E-17 Result Below MDC Uranium-238 3rd Qtr 2023 1.95E-16 7.39E-17 7.52E-17 3.30E-17 0.00 Uranium-233/234 4th Qtr 2023 2.62E-16 8.73E-17 8.93E-17 4.13E-17 0.00 Uranium-235/236 4th Qtr 2023 2.55E-17 3.34E-17 3.34E-17 5.09E-17 Result Below MDC Uranium-238 4th Qtr 2023 2.27E-16 8.10E-17 8.26E-17 4.12E-17 0.00 Uranium-233/234 3rd Qtr 2023 2.90E-16 1.07E-16 1.09E-16 4.60E-17 0.00 Uranium-235/236 3rd Qtr 2023 1.50E-17 3.35E-17 3.35E-17 6.71E-17 Result Below MDC Uranium-238 3rd Qtr 2023 3.20E-16 1.12E-16 1.14E-16 3.99E-17 0.00 Uranium-233/234 4th Qtr 2023 2.27E-16 9.39E-17 9.53E-17 4.02E-17 0.00 Uranium-235/236 4th Qtr 2023 7.52E-18 2.38E-17 2.38E-17 5.70E-17 Result Below MDC Uranium-238 4th Qtr 2023 2.20E-16 9.39E-17 9.52E-17 5.80E-17 0.00 Container Receipt and Dispatch Building -1100 (CRDB 1100) Fume Hood Exhaust (FHGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta 0.01%
0.01%
2.37E+06 Result Below MDC 10/9/2023 1100-562-1MA1 1100-562-1MA2 0.01%
8.24E+05 0.01%
1/5/2024 10/9/23 - 1/5/24 7/6/23 - 10/9/23 0.01%
1.83E+06 0.01%
Result Below MDC 0.01%
% of Table 2 of Appendix B to 10 CFR 20 Values 2.19E+06 10/9/23 - 1/5/24 Result Below MDC 1/5/2024 Result Below MDC 0.01%
10/9/2023 7/6/23 - 10/9/23 Notes:
TABLE 1-6 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100): Fume Hood Exhaust Gaseous Effluent Vent System, 1100-562-2MA1 &
1100-562-2MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2023 URENCO USA Lea County, New Mexico Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)
Sample Period Analyte Gross Result (Ci/ml)
MDA (Ci/ml)
@ 95 CL Instrument Unc (Ci/ml)
Total Vent System Flow (m3)
Quantity Released (Ci)
% of Table 2 of Appendix B to 10 CFR 20 Values 11005622MA1 070623 08/02/2023 1319 07/06/23 - 08/02/23 6.56E-17 4.91E-16 6.76E-08 1.51E+07
<MDA
<MDA 11005622MA1 080223 09/01/2023 1148 08/02/23 - 09/01/23 9.40E-17 7.04E-16 6.76E-08 3.11E+07
<MDA
<MDA 11005622MA1 090123 11/09/2023 1130 09/01/23 - 11/09/23 2.70E-16 6.59E-16 1.22E-07 2.04E+07
<MDA
<MDA 11005622MA1 110923 12/11/2023 1056 11/09/23 - 12/11/23 2.92E-17 4.91E-16 6.76E-08 2.38E+07
<MDA
<MDA 11005622MA1 121123 01/05/2024 1401 12/11/23 -01/05/24 6.90E-14 5.16E-13 6.76E-08 6.78E+02
<MDA
<MDA 11005622MA1 070623 08/02/2023 1319 07/06/23 - 08/02/23 6.78E-16 4.68E-15 1.34E-06 1.51E+07
<MDA
<MDA 11005622MA1 080223 09/01/2023 1148 08/02/23 - 09/01/23 6.68E-15 6.70E-15 1.71E-06 3.11E+07
<MDA
<MDA 11005622MA1 090123 11/09/2023 1130 09/01/23 - 11/09/23 5.76E-15 6.28E-15 1.63E-06 2.04E+07
<MDA
<MDA 11005622MA1 110923 12/11/2023 1056 11/09/23 - 12/11/23 1.81E-15 4.68E-15 1.55E-06 2.38E+07
<MDA
<MDA 11005622MA1 121123 01/05/2024 1401 12/11/23 -01/05/24 3.56E-15 4.92E-15 1.56E-06 6.78E+02
<MDA
<MDA 11005622MA2 070623 08/02/2023 1324 07/06/23 - 08/02/23 1.06E-16 7.96E-16 6.76E-08 2.79E+02
<MDA
<MDA 11005622MA2 080223 12/11/2023 1059 08/02/23 - 12/11/23 4.73E-17 1.71E-16 9.91E-08 1.33E+08
<MDA
<MDA 11005622MA2 121123 01/05/2024 1403 12/11/23 - 01/05/24 3.42E-16 8.35E-16 1.22E-07 7.18E+02
<MDA
<MDA 11005622MA2 070623 08/02/2023 1324 07/06/23 - 08/02/23 6.59E-15 7.58E-15 1.61E-06 2.79E+02
<MDA
<MDA 11005622MA2 080223 12/11/2023 1059 08/02/23 - 12/11/23 1.57E-15 1.63E-15 1.64E-06 1.33E+08
<MDA
<MDA 11005622MA2 121123 01/05/2024 1403 12/11/23 - 01/05/24 7.29E-15 7.95E-15 1.63E-06 7.18E+02
<MDA
<MDA Gross Beta Gross Beta 1100-562-2MA2 1100-562-2MA1 Gross Alpha Gross Alpha Container Receipt and Dispatch Building -1100 (CRDB 1100) Fume Hood Exhaust (LXGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta Radionuclide Sample Date (Off Date)
Sample Period Result (Ci/ml)
Uncertainty (2 sigma)
(Ci/ml)
Uncertainty (1 sigma)
(Ci/ml)
MDC (Ci/ml)
Total Flow (m3)
Quantity Released (Ci)
Uranium-233/234 3rd Qtr 2023 3.19E-16 1.31E-16 1.33E-16 6.94E-17 1.47E-08 Uranium-235/236 3rd Qtr 2023 4.82E-17 6.31E-17 6.32E-17 9.63E-17 Result Below MDC Uranium-238 3rd Qtr 2023 3.20E-16 1.30E-16 1.32E-16 6.30E-17 0.00E+00 Uranium-233/234 4th Qtr 2023 4.04E-16 1.24E-16 1.28E-16 5.39E-17 0.00 Uranium-235/236 4th Qtr 2023 7.76E-17 6.18E-17 6.21E-17 6.65E-17 0.00 Uranium-238 4th Qtr 2023 2.85E-16 1.02E-16 1.04E-16 3.79E-17 0.00 Uranium-233/234 3rd Qtr 2023 1.53E-15 5.09E-16 5.21E-16 1.97E-16 4.26E-13 Uranium-235/236 3rd Qtr 2023 2.51E-16 2.42E-16 2.42E-16 3.01E-16 Result Below MDC Uranium-238 3rd Qtr 2023 9.77E-16 4.08E-16 4.14E-16 2.47E-16 0.00E+00 Uranium-233/234 4th Qtr 2023 2.94E-16 9.49E-17 9.72E-17 4.61E-17 0.00 Uranium-235/236 4th Qtr 2023 3.39E-17 3.50E-17 3.51E-17 3.74E-17 Result Below MDC Uranium-238 4th Qtr 2023 3.47E-16 1.03E-16 1.06E-16 3.82E-17 0.00 0.011%
1.33E+08 0.033%
0.051%
1/5/2024 7/6/23 - 9/1/23 4.62E+07 0.011%
9/1/23 - 1/5/24 0.010%
% of Table 2 of Appendix B to 10 CFR 20 Values 0.010%
8/2/23 - 1/5/24 1100-562-2MA1 7/6/23 - 8/2/23 0.003%
0.012%
Result Below MDC 2.79E+02 Result Below MDC 4.41E+07 0.013%
8/2/2023 1/5/2024 9/1/2023 1100-562-2MA2 Container Receipt and Dispatch Building -1100 (CRDB 1100) Local Extract Exhaust (LXGEVS) Gaseous Effluent Vent System-Gross Alpha & Beta Result Below MDC Notes:
Filter change-out in October did not occur due to unit maintenance.
1100-562-2MA1: Total Vent System Flow for filter period 8/2/23 - 9/1/23 collected from redundant monitor (1100-562-2MA2) due to maintenance issue on 2MA1 unit.
1100-562-2MA2: Filter change-out in September, October, and November did not occur due to redundant monitor (1100-562-2MA1) maintenance.
- 1.
Ci = Curies
- 2.
µCi/ml = micro-Curies per milliliter.
- 3.
m³ = cubic meters.
- 4.
MDA = minimum detectable activity.
- 5.
MDC= minimum detectable concentration.
- 6.
Quantity released is calculated if the result Equals or Exceeds MDA or MDC.
- 7.
Radionuclides analyzed using Procedure EPA 908.0 Modified by Eberline Analytical Corp of Oak Ridge, TN.
- 8.
Gross alpha and beta analyzed by URENCO USA per procedure EN-3-3030-01.