MONTHYEARInspection Manual Change Notice 24-023, Table of Contents for Inspection Manual Change Notice 24-0232024-07-29029 July 2024 Table of Contents for Inspection Manual Change Notice 24-023 ML24150A2392024-07-29029 July 2024 IMC 2562 Light-Water Reactor Inspection Program for Restart of Reactor Facilities Following Permanent Cessation of Power Operations Inspection Manual Change Notice 24-022, Table of Contents for Inspection Manual Change Notice 24-0222024-07-26026 July 2024 Table of Contents for Inspection Manual Change Notice 24-022 Inspection Manual Change Notice 24-021, Table of Contents for Inspection Manual Change Notice 24-0212024-07-24024 July 2024 Table of Contents for Inspection Manual Change Notice 24-021 Inspection Manual Change Notice 24-018, Table of Contents for Inspection Manual Change Notice 24-0182024-07-0101 July 2024 Table of Contents for Inspection Manual Change Notice 24-018 Inspection Manual Change Notice 24-016, Table of Contents for Inspection Manual Change Notice 24-0162024-05-30030 May 2024 Table of Contents for Inspection Manual Change Notice 24-016 Inspection Manual Change Notice 24-015, Table of Contents for Inspection Manual Change Notice 24-0152024-05-16016 May 2024 Table of Contents for Inspection Manual Change Notice 24-015 Inspection Manual Change Notice 24-014, Table of Contents for Inspection Manual Change Notice 24-0142024-05-10010 May 2024 Table of Contents for Inspection Manual Change Notice 24-014 ML24044A2152024-05-10010 May 2024 IMC 0306 Planning, Scheduling, Tracking, and Reporting of the Reactor Oversight Process (ROP) Inspection Manual Change Notice 24-013, Table of Contents for Inspection Manual Change Notice 24-0132024-04-23023 April 2024 Table of Contents for Inspection Manual Change Notice 24-013 ML24033A2992024-04-23023 April 2024 IMC 2562 Light-Water Reactor Inspection Program for Restart of Reactor Facilities Following Permanent Cessation of Power Operations Inspection Manual Change Notice 24-012, Table of Contents for Inspection Manual Change Notice 24-0122024-04-22022 April 2024 Table of Contents for Inspection Manual Change Notice 24-012 Inspection Manual Change Notice 24-010, Table of Contents for Inspection Manual Change Notice 24-0102024-03-14014 March 2024 Table of Contents for Inspection Manual Change Notice 24-010 Inspection Manual Change Notice 24-009, Table of Contents for Inspection Manual Change Notice 24-0092024-03-0808 March 2024 Table of Contents for Inspection Manual Change Notice 24-009 Inspection Manual Change Notice 24-008, Table of Contents for Inspection Manual Change Notice 24-0082024-03-0404 March 2024 Table of Contents for Inspection Manual Change Notice 24-008 Inspection Manual Change Notice 24-007, Table of Contents for Inspection Manual Change Notice 24-0072024-02-12012 February 2024 Table of Contents for Inspection Manual Change Notice 24-007 Inspection Manual Change Notice 24-006, Table of Contents for Inspection Manual Change Notice 24-0062024-02-0707 February 2024 Table of Contents for Inspection Manual Change Notice 24-006 Inspection Manual Change Notice 24-005, Table of Contents for Inspection Manual Change Notice 24-0052024-02-0707 February 2024 Table of Contents for Inspection Manual Change Notice 24-005 ML23318A2002024-01-0909 January 2024 IMC 0307 Appendix D, Resident Inspector Retention and Recruitment Program Monitoring and Assessment Inspection Manual Change Notice 24-002, Table of Contents for Inspection Manual Change Notice 24-0022024-01-0909 January 2024 Table of Contents for Inspection Manual Change Notice 24-002 ML23307A0092024-01-0202 January 2024 IMC 2515 Appendix E, Inspection Program Modifications During Public Health Emergencies or Other Conditions Restricting Inspector Onsite Presence Inspection Manual Change Notice 24-001, Table of Contents for Inspection Manual Change Notice 24-0012024-01-0202 January 2024 Table of Contents for Inspection Manual Change Notice 24-001 Inspection Manual Change Notice 23-039, Table of Contents for Inspection Manual Change Notice 23-0392023-12-21021 December 2023 Table of Contents for Inspection Manual Change Notice 23-039 ML23318A4262023-12-15015 December 2023 IP 71111.21N.04 Age-Related Degradation Inspection Manual Change Notice 23-037, Table of Contents for Inspection Manual Change Notice 23-0372023-12-15015 December 2023 Table of Contents for Inspection Manual Change Notice 23-037 ML23234A1762023-12-14014 December 2023 IMC 0309 Reactive Inspection Decision Basis for Power Reactors Inspection Manual Change Notice 23-035, Table of Contents for Inspection Manual Change Notice 23-0352023-12-0606 December 2023 Table of Contents for Inspection Manual Change Notice 23-035 Inspection Manual Change Notice 23-034, Table of Contents for Inspection Manual Change Notice 23-0342023-11-15015 November 2023 Table of Contents for Inspection Manual Change Notice 23-034 Inspection Manual Change Notice 23-033, Table of Contents for Inspection Manual Change Notice 23-0332023-11-0606 November 2023 Table of Contents for Inspection Manual Change Notice 23-033 ML23214A3822023-10-31031 October 2023 IMC 0308, Attachment 2, Technical Basis for Inspection Program ML23222A1682023-10-31031 October 2023 IMC 0611 Appendix D Guidance for Problem Identification and Resolution Inspection Reports Inspection Manual Change Notice 23-032, Table of Contents for Inspection Manual Change Notice 23-0322023-10-31031 October 2023 Table of Contents for Inspection Manual Change Notice 23-032 ML23226A2232023-10-16016 October 2023 IP 71111.08 Inservice Inspection Activities Inspection Manual Change Notice 23-030, Table of Contents for Inspection Manual Change Notice 23-0302023-10-16016 October 2023 Table of Contents for Inspection Manual Change Notice 23-030 Inspection Manual Change Notice 23-028, Table of Contents for Inspection Manual Change Notice 23-0282023-09-19019 September 2023 Table of Contents for Inspection Manual Change Notice 23-028 Inspection Manual Change Notice 23-026, Table of Contents for Inspection Manual Change Notice 23-0262023-08-28028 August 2023 Table of Contents for Inspection Manual Change Notice 23-026 ML23191A5172023-08-18018 August 2023 IP 71111.07 Heat Exchanger/Sink Performance Inspection Manual Change Notice 23-024, Table of Contents for Inspection Manual Change Notice 23-0242023-08-17017 August 2023 Table of Contents for Inspection Manual Change Notice 23-024 Inspection Manual Change Notice 23-023, Table of Contents for Inspection Manual Change Notice 23-0232023-08-11011 August 2023 Table of Contents for Inspection Manual Change Notice 23-023 Inspection Manual Change Notice 23-021, Table of Contents for Inspection Manual Change Notice 23-0212023-07-27027 July 2023 Table of Contents for Inspection Manual Change Notice 23-021 Inspection Manual Change Notice 23-020, Table of Contents for Inspection Manual Change Notice 23-0202023-07-14014 July 2023 Table of Contents for Inspection Manual Change Notice 23-020 ML23192A8372023-07-12012 July 2023 IP 71111.21N.04 Age-Related Degradation ML23055B0532023-06-26026 June 2023 IMC 2515 Appendix E, Inspection Program Modifications During Public Health Emergencies or Other Conditions Restricting Inspector Onsite Presence ML23151A5462023-06-26026 June 2023 IMC 2515 Appendix C, Special and Infrequently Performed Inspections Inspection Manual Change Notice 23-018, Table of Contents for Inspection Manual Change Notice 23-0182023-06-26026 June 2023 Table of Contents for Inspection Manual Change Notice 23-018 Inspection Manual Change Notice 23-017, Table of Contents for Inspection Manual Change Notice 23-0172023-06-16016 June 2023 Table of Contents for Inspection Manual Change Notice 23-017 Inspection Manual Change Notice 23-016, Table of Contents for Inspection Manual Change Notice 23-0162023-06-14014 June 2023 Table of Contents for Inspection Manual Change Notice 23-016 Inspection Manual Change Notice 23-014, Table of Contents for Inspection Manual Change Notice 23-0142023-05-18018 May 2023 Table of Contents for Inspection Manual Change Notice 23-014 ML23135A7272023-05-15015 May 2023 Table of Contents for Inspection Manual Change Notice Inspection Manual Change Notice 23-012, Table of Contents for Inspection Manual Change Notice 23-0122023-05-0404 May 2023 Table of Contents for Inspection Manual Change Notice 23-012 2024-07-29
[Table view]Some use of "" in your query was not closed by a matching "". |
Text
NRC INSPECTION MANUAL DI
INSPECTION PROCEDURE 61706
CORE THERMAL POWER EVALUATION
PROGRAM APPLICABILITY: 2515 (SUPPLEMENTAL), 2525
61706-01 INSPECTION OBJECTIVE To verify that the calculation of core thermal power is correct and that the procedure used is technically adequate.
61706-02 INSPECTION REQUIREMENTS 02.01 Review the licensee's core thermal power evaluation procedure for boiling-water reactors (BWRs), pressurized-water reactors (PWRs), and high-temperature gas-cooled reactor (HTGR) at
>50% power for the following:
- a. Examine the "Core Performance Evaluation" data sheet, orequivalent, and verify that data are reasonable, consistent with previous data, and properly recorded.
- b. Review the procedure for initial conditions and prerequisites.
- c. Verify that the test and plant instruments used to obtain dataare properly calibrated.
- d. Review the licensee's core thermal power calculations toverify that they are correct.
- e. Verify that the power range nuclear instruments are properlyadjusted to agree with the results of the heat balance.
- f. Verify generator blowdown system during the core thermal powerthat the procedure specifies the condition of the steam evaluation (PWR only).
02.02 Verify, by a 1-month sample, that the frequency of evaluations is as presc ribed by the Plant's Technical Specifications (TS).
02.03 Independently calculate the core thermal power using the licensee's procedure for manual calculations or an NRC-developed calculation such as TPDWR1.
Issue Date: 07/14/86 61706 02.04 Verify that the core thermal power evaluation r esults were reviewed, approved, and documented in accordance with t he licensee's administrative control procedures.
61706 Issue Date: 07/14/86 61706-03 INSPECTION GUIDANCE General Guidance. The thermal power of the BWR, PWR, and the HTGR is determined by a heat balance on the reactor system using operating data. Under steady-state conditions, the reactor heat output is obtained as the difference between the total heat removed from the reactor system and the total heat added in the flow streams returning to the reactor. A core heat balance in the power range is made to ensure that the core is operated at all times within the required thermal limits and/or fuel warranty requirements. Thermal power calculation is performed either by the plant's computer or by a manual method. The latter is normally required when the computer program is not working or to double check results obtained from the computer.
03.01 Specific Guidance
- a. Inspection Requirement 02.01b. Typical initial conditions and prerequisites for a core thermal power determination are as follows:
- 1. At the desired power level, the plant is operated for asufficient length of time to show that steady-state operating conditions have been attained.
- 2. Feedwater flow, water lev els, and all controllabletemperatures and pressures are maintained as nearly as possible, unchanged throughout the data ac quisition period.
- b. Inspection Requirement 02.01c. Although some of the instru-ments and most of the com puter points may not be safety related, they must be calibrated in a traceable manner if they are used to verify operation within the licensed power limit.
In many situations, problems with input data are far more common findings than findings of inadequate heat balance equations or poor arithmetic.
- c. Inspection the rate of heat transfer to the steam system plus certainRequirement 02.01d. The thermal power is equal to heat losses, less the power contributed by the main coolant pumps (recirculating pumps in BWRs). The heat transfer to the system is equal to the enthalpy difference between the feedwater and the steam, multiplied by the mass flow of the feedwater. For PWRs this quantity must be calculated for each steam generator and summed. The minor heat losses are added.
These include heat losses through the thermal insulation and the net loss between the letdown and the makeup to and from the reactor water cleanup system (or gas cleanup system for gas cooled reactors). The loss from steam generator blowdown is also added, if this is present. The heat added by the large reactor coolant pumps is subtracted.
- d. Inspection Requirement 02.01eaverage power range monitor ( APRM) amplifier should be. For BWRs the gain of each heat balance, is adjusted or verified to read the APRM valueadjusted so that each APRM, following d etermination of the
Issue Date: 07/14/86 61706 required by plant procedures and/or TS. Likewise, for PWRs and HTGRs, the power range instru ments are adjusted to the reactor power indicated by the heat balance.
Core thermal power evaluation is performed on a daily basis for both PWRs and BWRs. The specific requirements can be found in the plant's TS although the plant may follow more stringent guidelines as recommended by the manufacturer.
Refer to Inspection Procedure 61705, "Calibration of Nuclear Instrumentation Systems," if calibration is required. In addition, the inspector should check that the average power level over any 8-hour shift did not exceed the "full steady-state licensed power level" (and similarly worded terms). The exact 8-hour periods defined as "shifts" are up to the plant, but should not be varied from day to day (the easiest definition is a normal shift manned by a particular "crew").
It is permissible to briefly exceed the "full, steady-state licensed power level" by as much as 2% for as long as 15 minutes. In no case should 102% power be exceeded, but lesser power "excursions" for longer periods should be allowed, with the above as guidance. For example, 1% excess for 30 minutes and 1/2% for 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> should be allowed. There are no limits on the number of times these "excursions" may occur, or the time interval that must separate such "excursions." The above requirement regarding the 8-hour average power will prevent abuse of this allowance.
- e. Inspection Requirement 02.01f. The steam generator blowdown system is designed to remove dissol ved solids and other impurities from the steam generator. If the blowdown is in progress during the core thermal power evaluation, consideration of the mass flow and enthalpy of this blowdown should be based on a review of the licensee's calculations and assumptions.
- f. Inspection Requirement 02.03. Manual calculation is intended as a backup for the computer-calculated thermal power in case the computer is not operating. Manual calculation is inherently not as accurate as the computer-calculated thermal power. However, despite its accuracy limitations, the manual calculation should agree within +/-5% of the computer-calculated thermal power (MWe). Even though the +/-5% tolerance is not a requirement, a difference of >5% between the computer calculation and manual calculation indicates in all likelihood that an error in either the computer calculation or the manual calculation has been made. Most manual calculations performed utilizing data from the computer are within 1% of the computer-calculated thermal power.
An NRC program for Westinghouse PWRs entitled "TPDWR2:
Thermal Power Determination for Westinghouse Reactors, Version 2", is available from the Engineering and Generic Communications Branch for use on the IBM PC. Users of this program should refer to the user's guide, NUREG-1 167. A similar program for use on Combustion Engineering's reactors
61706 Issue Date: 07/14/86 entitled "TPDCER2: Thermal Power Determination for Combustion Engineering Reactors, Version 2", and the users guide for this program is also available from the Generic Communications Branch.
END
Issue Date: 07/14/86 61706