Channel Head Inspection Guidance Greg Makar, NRR/DNRL/NCSG NRC Meeting with Industry Steam Generator Task Force February 22, 2024
=
Background===
- Expand on the NRC presentation and meeting summary from September 2023
- Principal guidance documents are:
-GALL Report (NUREG-1801, Rev. 2)
-SRP-LR (NUREG-1800, Rev. 2)
-LR-ISG-2016-01
-GALL-SLR (NUREG-2191, Rev. 0)
-SRP-SLR (NUREG-2192, Rev. 0) 2
Purpose Clarify NRC guidance on steam generator primary surface inspections for initial and subsequent license renewal (LR and SLR)
- Divider plate assembly
- Tube-to-tubesheet welds
- Channel head interior surface
- Tubesheet 3
Terminology
- A plant-specific aging management program (AMP) is an AMP that includes additional programs beyond the Water Chemistry and Steam Generators programs (e.g., One-Time Inspection)
- Defined in SRP-SLR and LR-ISG-2016-01
- Industry analysis applicable and bounding refers to EPRI Report 3002002850, Steam Generator Management Program: Investigation of Crack Initiation and Propagation in the Steam Generator Channel Head Assembly 4
General Visual Inspection
- Intended to identify signs of cracking or loss of material (e.g., made visible by rust stains)
- Applies to the following, regardless of material:
- Divider plate assembly
- Tube-to-tubesheet welds
- Channel head interior surface
- Tubesheet (primary side)
- Materials, alternate repair criteria, and applicability of bounding industry analysis determine the need for a plant-specific AMP 5
General Visual Inspection Divider Plate Assembly and Tube-to-Tubesheet Welds Initial License Renewal Subsequent License Renewal Included in NUREG-1801, Rev. 2, AMP XI.M19 (as revised by LR-ISG-2016-01)
Program Description Scope of Program Parameters Monitored or Inspected Detection of Aging Effects Monitoring and Trending Acceptance Criteria Included in NUREG-2191, AMP XI.M19 Program Description Scope of Program Parameters Monitored or Inspected Detection of Aging Effects Monitoring and Trending Acceptance Criteria Further Evaluation Guidance in NUREG-1800, Rev. 2 (as revised by LR-ISG-2016-01)
Section 3.1.2.2.11.1 for divider plate assembly Section 3.1.2.2.11.2 for tube-to-tubesheet welds Further Evaluation Guidance in NUREG-2192 Section 3.1.2.2.11.1 for divider plate assembly Section 3.1.2.2.11.2 for tube-to-tubesheet welds 6
General Visual Inspection Channel Head Interior Surfaces and Tubesheet Initial License Renewal Subsequent License Renewal Included in NUREG-1801, Rev. 2, AMP XI.M19 (as revised by LR-ISG-2016-01)
Program Description Scope of Program Parameters Monitored or Inspected Detection of Aging Effects Monitoring and Trending Acceptance Criteria Included in NUREG-2191, AMP XI.M19 Program Description Scope of Program Parameters Monitored or Inspected Detection of Aging Effects Monitoring and Trending Acceptance Criteria 7
Divider Plate Cracking Guidance Visual representation of Further Evaluation Section 3.1.2.2.11.1 8
Material Weld Material Industry analysis (EPRI 3002002850) applicable and bounding Plant-specific program required beyond existing programs1 690 690 N/A No 600 600 Yes No 600 600 No Yes 1 If a plant-specific program is not necessary, then aging is managed by the existing Water Chemistry and Steam Generators programs
Tube-to-Tubesheet Weld Cracking Guidance Visual representation of Further Evaluation Section 3.1.2.2.11.2 9
Tube Material Tubesheet Cladding Material Alternate Repair Criteria (C*, F*, W*,
or H*) approved for both hot-and cold-leg side of SG Industry analysis (EPRI 3002002850) applicable and bounding Plant-specific program required beyond existing programs1 690 690 N/A N/A No 690 600 N/A Yes No 690 600 N/A No Yes 600 N/A Yes N/A No 600 N/A No N/A Yes 1 If a plant-specific program is not necessary, then aging is managed by the existing Water Chemistry and Steam Generators programs
Summary
- The Steam Generators and Water Chemistry AMPs are used by all plants to manage aging of the primary surfaces
- Visual inspection of primary surfaces is in the current guidance for both initial and subsequent license renewal
- Further Evaluation Sections 3.1.2.2.11.1 and 3.1.2.2.11.2
- A plant-specific program may be needed to evaluate the effectiveness of the Steam Generators and Water Chemistry programs
- The need for a plant-specific program is evaluated according to:
- The divider plate assembly, tube, and tubesheet cladding materials
- Whether or not the steam generator is bounded by the industry analyses
- Alternate repair criteria affecting the tube-to-tubesheet welds 10
References NUREG-1800, Revision 2, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants, dated December 2010 (ML103490036)
NUREG-1801, Revision 2, Generic Aging Lessons Learned (GALL) Report, dated December 2010 (ML103490041)
LR-ISG-2016-01, Changes to Aging Management Guidance for Various Steam Generator Components, dated November 2016 (ML16237A383)
NUREG-2191, Revision 0, Generic Aging Lessons Learned for Subsequent License Renewal (GALL-SLR) Report, dated July 2017 (ML17187A031 (Volume 1) and ML17187A204 (Volume 2))
NUREG-2192, Revision 0, Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants, dated July 2017 (ML17188A158)
EPRI Report 3002002850, Steam Generator Management Program: Investigation of Crack Initiation and Propagation in the Steam Generator Channel Head Assembly 11
References (contd)
NUREG-2191, Revision 1, Draft, published July 2023, (ML23180A182 (Volume 1),
ML23180A188 (Volume 2))
NUREG-2192, Revision 1, Draft, published July 2023 (ML23180A191)
Corrected Tables 3.1-1 and 3.2-1, published August 2023 (ML23213A036)
NUREG-2221, Supplement 1, Technical Bases for Changes in the Subsequent License Renewal Guidance Documents NUREG-2191 and NUREG-2192, Draft for Comment, published July 2023 (ML23180A208)
NRC Meeting with the Industry Steam Generator Task Force, September 7, 2023 Meeting Summary (ML23268A340)
Industry Slides (ML23240A002)
NRC Slides (ML23244A175) 12