ML24051A034
ML24051A034 | |
Person / Time | |
---|---|
Issue date: | 02/22/2024 |
From: | Gregory Makar NRC/NRR/DNRL/NCSG |
To: | |
References | |
Download: ML24051A034 (1) | |
Text
Channel Head Inspection Guidance
Greg Makar, NRR/DNRL/NCSG
NRC Meeting with Industry Steam Generator Task Force February 22, 2024
Background
- Expand on the NRC presentation and meeting summary from September 2023
- Principal guidance documents are:
- GALL Report (NUREG-1801, Rev. 2)
- SRP-LR (NUREG-1800, Rev. 2)
- LR-ISG-2016- 01
- GALL-SLR (NUREG-2191, Rev. 0)
- SRP-SLR (NUREG-2192, Rev. 0)
2 Purpose
Clarify NRC guidance on steam generator primary surface inspections for initial and subsequent license renewal (LR and SLR)
- Divider plate assembly
- Tube-to-tubesheet welds
- Channel head interior surface
- Tubesheet
3 Terminology
- A plant -specific aging management program (AMP) is an AMP that includes additional programs beyond the Water Chemistry and Steam Generators programs (e.g., One-Time Inspection)
- Defined in SRP-SLR and LR-ISG-2016- 01
- Industry analysis applicable and bounding refers to EPRI Report 3002002850, Steam Generator Management Program: Investigation of Crack Initiation and Propagation in the Steam Generator Channel Head Assembly
4 General Visual Inspection
- Intended to identify signs of cracking or loss of material (e.g., made visible by rust stains)
- Applies to the following, regardless of material:
- Divider plate assembly
- Tube-to-tubesheet we l d s
- Channel head interior surface
- Tubesheet (primary side)
- Materials, alternate repair criteria, and applicability of bounding industry analysis determine the need for a plant-specific AMP
5 General Visual Inspection Divider Plate Assembly and Tube-to-Tubesheet We l d s Initial License Renewal Subsequent License Renewal Included in N U REG -1801, Rev. 2, AMP Included in NUREG-2191, AMP XI.M19 XI.M19 (as revised by LR-ISG-2016- 01)* Program Description
- Program Description
- Scope of Program
- Scope of Program
- Parameters Monitored or Inspected
- Parameters Monitored or Inspected
- Detection of Aging Effects
- Detection of Aging Effects
- Monitoring and Trending
- Monitoring and Trending
- Acceptance Criteria
- Acceptance Criteria Further Evaluation Guidance in Further Evaluation Guidance in N U REG-1800, Rev. 2 (as revised by N U REG-2192 LR-ISG-2016- 01)* Section 3.1.2.2.11.1 for divider plate
- Section 3.1.2.2.11.1 for divider plate assembly assembly
- Section 3.1.2.2.11.2 for tube-to-
6 General Visual Inspection Channel Head Interior Surfaces and Tubesheet
Initial License Renewal Subsequent License Renewal Included in N U REG -1801, Rev. 2, AMP Included in NUREG-2191, AMP XI.M19 XI.M19 (as revised by LR-ISG-2016- 01)* Program Description
- Program Description
- Scope of Program
- Scope of Program
- Parameters Monitored or Inspected
- Parameters Monitored or Inspected
- Detection of Aging Effects
- Detection of Aging Effects
- Monitoring and Trending
- Monitoring and Trending
- Acceptance Criteria
- Acceptance Criteria
7 Divider Plate Cracking Guidance
Visual representation of Further Evaluation Section 3.1.2.2.11.1 Material Weld Material Industry analysis Plant-specific (EPRI 3002002850) program required applicable and beyond existing bounding programs1 690 690 N /A No 600 600 Ye s No 600 600 No Ye s
1 If a plant-specific program is not necessary, then aging is managed by the existing Water Chemistry and Steam Generators programs
8 Tube-to-Tubesheet Weld Cracking Guidance
Visual representation of Further Evaluation Section 3.1.2.2.11.2 Tube Tubesheet Alternate Repair Industry analysis Plant-specific Mate ri al Cladding Criteria (C*, F*, W*, (EPRI 3002002850) program Mate ri al or H*) approved for applicable and required both hot-and cold-bounding beyond leg side of SG existing programs1 690 690 N /A N /A No 690 600 N /A Ye s No 690 600 N /A No Ye s 600 N /A Ye s N /A No 600 N /A No N /A Ye s
1 If a plant-specific program is not necessary, then aging is managed by the existing Water Chemistry and Steam Generators programs
9 Summary
- The Steam Generators and Water Chemistry AMPs are used by all plants to manage aging of the primary surfaces
- Visual inspection of primary surfaces is in the current guidance for both initial and subsequent license renewal
- S tea m Gen erato rs A M P
- Further Evaluation Sections 3.1.2.2.11.1 and 3.1.2.2.11.2
- A plant-specific program may be needed to evaluate the effectiveness of the Steam Generators and Water Chemistry programs
- The need for a plant-specific program is evaluated according to:
- The divider plate assembly, tube, and tubesheet cladding materials
- Whether or not the steam generator is bounded by the industry analyses
- Alternate repair criteria affecting the tube-to-tubesheet welds
10 References
- N U REG-1800, Revision 2, Standard Review Plan for Review of License Renewal Applications for Nuclear Power Plants, dated December 2010 (ML10 3490036)
- N U REG-1801, Revision 2, Generic Aging Lessons Learned (GALL) Report, dated December 2010 (ML103490041)
- LR-ISG-2016- 01, Changes to Aging Management Guidance for Various Steam Generator Components, dated November 2016 (ML16237A383)
- N U REG-2191, Revision 0, Generic Aging Lessons Learned for Subsequent License Renewal (GALL-SLR) Report, dated July 2017 (ML17187A031 (Volume 1) and ML17187A204 (Volume 2))
- N U REG-2192, Revision 0, Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants, dated July 2017 (ML17188A158)
- EPRI Report 3002002850, Steam Generator Management Program: Investigation of Crack Initiation and Propagation in the Steam Generator Channel Head Assembly
11 References (cont d)
- N U REG-2191, Revision 1, Draft, published July 2023, (ML23180A182 (Volume 1),
ML23180A188 (Volume 2))
- N U REG-2192, Revision 1, Draft, published July 2023 (ML23180A191)
- Corrected Tables 3.1-1 and 3.2-1, published August 2023 (ML23213A036)
- N U REG-2221, Supplement 1, Technical Bases for Changes in the Subsequent License Renewal Guidance Documents NUREG-2191 and NUREG-2192, Draft for Comment, published July 2023 (ML23180A208)
- NRC Meeting with the Industry Steam Generator Task Force, September 7, 2023
- Meeting Summary (ML23268A340)
- Industry Slides (ML23240A002)
- NRC Slides (ML23244A175)
12 Questions
13