Cybersecurity Inspections Lessons Learned Public Meeting (Closed)
February 15, 2024 10:00 A.M. - 12:00 P.M.
Tammie Rivera, Cybersecurity Specialist Cyber Security Branch Division of Physical and Cyber Security Policy Office of Nuclear Security and Incident Response
Topics
- Key Messages
- Background
- 2023 Top 3 Trends (MTM Violations & Cross-Cutting Aspects)
- Observations
- Lessons Learned & Insights
- Next Steps
- Q & A 2
- This meeting focuses on cybersecurity baseline inspection activities conducted during CY 2023.
- Staff identified lessons learned and trends from the 2023 cybersecurity inspections.
- This effort will support identification of any actions needed to ensure efficiency and effectiveness of future inspections.
Key Messages 3
=
Background===
- Objectives of IP 71130.10
- 1. To provide assurance that digital equipment associated with safety, security, or emergency preparedness (SSEP) functions are adequately protected against cyber-attacks in accordance with (10 CFR) 73.54 and the licensee's approved cyber security plan (CSP).
- 2. To verify that CSP changes and reports are in accordance with 10 CFR 50.54(p).
Inspection Procedure 71130 Attachment 10, Cyber Security, (ML21155A209) 4
Background (continued)
- Inspection Requirements Excerpt from IP 71130.10, page 2:
- This inspection requirement range for completion is as follows:
- minimum of three inspection requirements,
- nominal four inspection requirements, and
- maximum, based on unusual circumstance, or special considerations, five inspection requirements.
- Inspection teams considered the following special considerations during development of cybersecurity team inspection plans:
- First biennial cycle completion using IP 71130.10
- High number of inspection findings during the biennial cycle 5
Inspection Procedure 71130 Attachment 10, Cyber Security, (ML21155A209)
Inspections and Violations 24 31 Total Baseline Inspections - Full Biennial Cycle Inspections for 2022 Inspections for 2023 55 Total 6
6 17 46 78 0
10 20 30 40 50 60 70 80 90 2022 2023 2022 2023 LIV LIV MTM MTM
- of Violations LIVS & MTMs by Year 183%
70%
2023 Top 3 Trends MTM Violations Most commonly cited NEI 08-091 security controls:
1.
Vulnerability Management (E.12) 2.
Baseline Configuration (E.10.3) 3.
Monitoring Tools and Techniques (E.3.4) 1 NEI 08-09, Cyber Security Plan for Nuclear Power Reactors, Revision 6, Addendum 1 Markup dated 2017 (ML17079A423) 2 IMC 0310, Aspects Within The Cross-cutting Areas, (ML19011A360) 7 Cross-Cutting Aspects (CCAs)
Most commonly cited CCAs as described in NRC IMC 03102:
1.
Conservative Bias (H.14) 2.
Resources (H.1) 3.
Procedure Adherence (H.8)
Observations
- Resources - Staffing and retention of well qualified cyber staff
- Training - properly trained staff and knowledge transfer (particularly, specialized training)
- Documentation - insufficient documentation (i.e. CDA assessments and alternate controls)
- Licensee cyber staff not thoroughly familiar with the requirements, guidance, or misinterpretation of the requirements 8
Lessons Learned
- A one-week inspection is challenging and resource intensive
- Inspectors have observed that the best performing sites and well-maintained cybersecurity programs have strong support from senior management
- Documentation still does not reflect the whole story
- Inspectors observed that some licensee staff lacked experience with regulatory requirements, background, and guidance related to the implementation of the cybersecurity program.
9
Insights
- Accurate and complete documentation improvement reduces the number of questions.
- The program is in the maintenance phase. Inspection focus on the defense-in-depth approach
- The NRC will continue to enhance the oversight program.
IMC 0612 Appendix E, "Examples of Minor Issues" 10
Next Steps
- An agency working group was established to evaluate alternate inspection procedure frequencies and team composition
- Reasons for establishing the working group:
Completing cybersecurity biennial inspections in one onsite week has been a challenge for regional inspection teams.
Inspection teams and licensee response teams need more time to address questions and disposition identified issues.
- The working group expects to present solutions that will gain efficiency and effectiveness
- The working group will develop recommendations for management consideration. Any proposed changes to the inspection procedure will be discussed at a later public meeting.
11
Questions & Discussion Trends Observations Lessons Learned Increase Efficiency 12
Submitting Meeting Feedback & POC To submit feedback and comments please:
- Navigate to this meeting on the NRC Public Meeting Schedule
- Click the Meeting Feedback Form link Meeting POC: Tammie Rivera Tammie.Rivera@nrc.gov Cyber Security Branch Division of Physical and Cyber Security Policy Office of Nuclear Security and Incident Response 13